1、A-A-50438 79 m 9999974 00b074q L m A-A-50438 26 March 1991 COMMERCIAL ITEM DESCRIPTION CLEANER, BLOWER AND VACUUM, PORTABLE, INDUSTRIAL The General Services Administration has authorized the use of this commercial item description as a replacement for MIL-C-21101, which is canceled. Abstract. This c

2、ommercial item description covers industrial type blower and vacuum cleaners intended primarily for cleaning and drying electric equipment. Blower and vacuum cleaners shall be of the following types: Type HV1 - High velocity, 115 Vac, 60 Hz. Type LV1 - Low velocity, 115 Vac, 60 Hz. Type MV1 - Medium

3、 velocity, 115 Vac, 60 Hz. Type MV2 - Medium velocity, 220 Vac, 50 Hz. Salient characteristics. 1. 2. 3. 4. 5. The cleaner shall be constructed of the type of materials that allow for the highest quality of performance. The cleaner shall conform to Underwriters Laboratory Standard UL 1017. The motor

4、s shall be of the universal type and able to operate continu- ously at 4OoC ambient temperature. The motor shall be provided with a guarded enclosure. outlined in table I. The cleaner shall conform to the characteristics The cleaner shall operate on a ungrounded electrical distribution system (shipb

5、oard use) such that an electrical shock hazard is not introduced. At normal full load operating conditions, the radio-frequency and low- frequency noise interference shall not exceed the limit specified for class IIB equipment of MIL-STD-461, The mounting of the noise suppression accessories shall b

6、e such that an electrical shock hazard is not introduced. Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any other data which may improve this docanent should be sent by letter to: Commander, Naval Sea Systems Command, Attn: 5523, Washington, DC 20362-5101. AMSC

7、 N/A FSC 7910 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50438 79 W 9999974 00b0745 3 A-A-50438 Table I. Cleaner chara

8、cteristics. Item Voltage, a.c. and d.c. Frequency, hertz (Hz) input watts, maximum Air discharge (at nozzle), minimum, cubic feet per minute (cfm) Switch, number of positions Inside diameter of discharge nozzle, inch 115 60 1,000 75 2 3/4 Type MV2 220 50 500 55 2 3/4 Type LV1 115 60 350 45 2 3/4 Typ

9、e MV1 115 60 500 55 2 3/4 6. The cleaner shall have a two position switch (on, off) for operating the cleaner which shall be mounted integral with the unit, shall be convenient and reliable for operation and of quick-break design, 7. The cleaner shall operate as a blower as well as a vacuum cleaner.

10、 8. The cleaner shall have either a 15 foot or 50 foot power cable, as specified in the ordering data. 9. The cleaner shall have a tapered, round, removable, nonconducting, discharge nozzle with an inside diameter as specified in table I. 10. The cleaner shall be provided with a scrap collection dev

11、ice of such construction as to prevent objects being drawn into the impeller with resultant damage to the impeller or impeller housing, or being thrown into the dust collection bag so as to penetrate the bag, thus creating a personnel safety hazard. The device shall be able to be attached to the int

12、ake side of the cleaner, and shall collect objects or hardware before they enter the impeller housing, while allowing the dust and air to pass into the dust collection bag. 11. When specified in the ordering data, attachments shall be supplied, as specified in table II. 12. Two copies of the manufac

13、turers standard operating and maintenance instructions shall be packed with each cleaner. manuals shall be a complete factory part lists and a list of all available accessories. The parts list should be annotated to show which parts can be purchased separately as repair parts. Included with the 2 Pr

14、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-I A-A- 50438 Table II. Attachments. I 1 Item ; Length of oil resis- Hose connection (suit- tant hose able for use on either blower or vacuum end) Dustproof bag, including connections Flat nozzle noncon- d

15、ucting) Shoulder strap Wall brush (for attachment to metal nozzle) Metal nozzle Spray attachment (1 quart capacity, for varnishes, paints, f cleaning fluid) Round brushes Round brush, 45 bend Length of oil resistant hose with swivel Extension piece (nonconducting)(in 2 pieces) Electronic equipment c

16、leaning brush, small arc type Electronic equipment cleaning brush (for confined places), toothbrush type Insulated cleaning brush Diameter Inches 1-1/2 3 3 1-1/2 1-1/2 Quantity Per cleaner 1 1 To be supplied with type LV1, HV1, MV1 Mv2 LV1, HV1, Mvl, Mv2 LV1, HV1, Mvl, Mv2 LV1, HV1, MV1, Mv2 LV1, HV

17、1, Mvl, Mv2 LV1, HV1, MV1, Mv2 LV1, Hvl, Mvl, Mv2 LV1, HV1, Mvl, Mv2 LV1, “1, Mv2 HV 1 HV1 IV 1 HV1 HV1 HV1 Contractor certification. ing evidence that the product offered meets the salient characteristics of this Commercial Item Description and that the product conforms to the producers own drawing

18、s, specifications, standards, and quality assurance practices, ment reserves the right to require proof of such conformance prior to first The contractor shall certify and maintain subctantiat- The govern- 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH

19、S-,-,-A-A- SO438 delivery and thereafter as may be otherwise provided for under the provisions of the contract. Metric products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, provided they fall within specified toleran

20、ces using conversion tables contained in the latest revision of FED-STD-376, and all other requirements of this Commercial Item Description are met. If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch-pound units, a request shall be made

21、 to the contracting officer to determine if the product is acceptable. The contracting officer has the option of accepting or rejecting the product. Regulatory reuuirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent pra

22、cticable, Preservation, packaging. packing, labelinE., and marking. Preservation, packaging, packing, labeling, and marking shall be as specified in the contract or order. Notes. 1. Ordering - data. Procurement documents should specify the following: (a) Title, number, and date of this commercial it

23、em description. (b) Type of cleaiier required. (c) Length of cord required, 15 or 50 ft. (d) User option - whether cleaners without attachments are required (e) Special marking(s), if required. MIL-STD-461 and FED-STD-376 are available from the Standardization Documents Order Desk, Building 4D, 700

24、Robbins Avenue, Philadelphia, PA 19111-5094. UL 1017 is available from Underwriters Laborztories, Incorporated, 333 Pfingsten Road, Northbrook, IL 60062. Certification number. by an ID number in the following format: Each type and configuration of cleaner shall be identified AAS 043 8/W - -z I A= 15

25、 ft. cord B= 50 ft. cord 1= 115 Vac 2= 220 Vac HV= Type HV MV= Type MV LV= Type LV 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-iFj A-A-50438 79 m 9999974 O060748 9 m A-A- 50438 The ID no. can be included on the identification plate of the clean

26、er and/or the enclosure of the cleaner. MILITARY INTERESTS: Custodians Army - GL Navy - SH Air Force - 84 Review activities Army - ME, CR, ER Navy - YD Air Force - 85 5 CIVIL AGENCY COORDINATING ACTIVITY: Preparing activity: Navy - SH (Project 7910-0079) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-