NAVY A-A-50618-1993 BATTERY STORAGE (PORTABLE SEALED MAINTENANCE-FREE LEAD-ACID) 6 VOLT 300 AMPERE-HOUR TYPE 6V-S-300 AH《6V-S-300 AH型6伏300安培小时砣酸免养护密封便携式畜电电池》.pdf

上传人:confusegate185 文档编号:976315 上传时间:2019-03-13 格式:PDF 页数:4 大小:142.84KB
下载 相关 举报
NAVY A-A-50618-1993 BATTERY STORAGE (PORTABLE SEALED MAINTENANCE-FREE LEAD-ACID) 6 VOLT 300 AMPERE-HOUR TYPE 6V-S-300 AH《6V-S-300 AH型6伏300安培小时砣酸免养护密封便携式畜电电池》.pdf_第1页
第1页 / 共4页
NAVY A-A-50618-1993 BATTERY STORAGE (PORTABLE SEALED MAINTENANCE-FREE LEAD-ACID) 6 VOLT 300 AMPERE-HOUR TYPE 6V-S-300 AH《6V-S-300 AH型6伏300安培小时砣酸免养护密封便携式畜电电池》.pdf_第2页
第2页 / 共4页
NAVY A-A-50618-1993 BATTERY STORAGE (PORTABLE SEALED MAINTENANCE-FREE LEAD-ACID) 6 VOLT 300 AMPERE-HOUR TYPE 6V-S-300 AH《6V-S-300 AH型6伏300安培小时砣酸免养护密封便携式畜电电池》.pdf_第3页
第3页 / 共4页
NAVY A-A-50618-1993 BATTERY STORAGE (PORTABLE SEALED MAINTENANCE-FREE LEAD-ACID) 6 VOLT 300 AMPERE-HOUR TYPE 6V-S-300 AH《6V-S-300 AH型6伏300安培小时砣酸免养护密封便携式畜电电池》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、A-A-50618 9999974 OLb2073 283 I INCH-POUND I A-A-50 6 18 3 December 1993 COMMERCIAL ITEM DESCRIPTION BATTERY, STORAGE (PORTABLE, SEALED, MAINTENANCE-FREE, LEAD-ACID) 6 VOLT, 300 AMPERE-HOUR, TYPE 6V-S-300 AH The General Services Administration has authorized the use of this Commercial Item Descripti

2、on. Abstract. This Commercial Item Description covers a 6 volt (normal and reversed), 300 ampere-hour sealed, valve-regulated lead-acid (VRLA), storage battery with a low rate and deep discharge duty cycle for use on Naval surface ships. Definition of Normal and Reversed. Looking at the battery top

3、with the intercell connectors in as shown, the positive terminal is located: at top right for Normal (N) at top left for Reversed (R) O I e I 9 Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Co

4、mmander, Naval Sea Systems Command, ATTN: 03R42, 2531 Jefferson Davis Hwy, Arlington, VA 22242-5160. FSC 6140 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50618

5、m i4 01b2074 1LT D A-A-506 18 When the battery intercell connector location is not designated, the battery top will appear as shown below: Salient characteristics. The product shall be a 6 volt (normal or reversed), 300 ampere-hour sealed lead-acid storage battery, meeting the requirements specified

6、 below. 1. Dimensions. The maximum dimensions for the battery shall be: length - 20.3 inches width - 9.9 inches height - 9.8 inches 2. Weiqht. The battery weight shall be 121 pounds maximum when filled. 3. Terminals. The terminals shall be posts with lugs capable of receiving a round end lug accepti

7、ng an AWG #O000 cable. 4. Pressure relief valve. The battery shall have sufficient pressure relief valves to prevent rupturing of the battery when internal pressure exceed battery design pressure. 5. capacity. a. The capacity for the 30 ampere (or 10 hour) rate shall be a minimum of 300 ampere-hours

8、 with a cut-off voltage of 5.25 volts in the temperature range of 20“ to 27“ C. b. The capacity for the 97.5 ampere (or 2 hour) rate shall be a minimum of 195 ampere-hours with a cut-off voltage of 4.8 volts in the temperature range of 20“ to 27“ C. 6. Reserve capacity. The battery shall deliver 25

9、amperes for a minimum of 600 minutes at 25C with a cut-off voltage of 5.25 volts. 7. Retention of charqe. The battery shall retain at least 80% of the 10 hour-rate capacity (300 ampere-hours) 28 days after charge termination when discharged at the 10 hour rate. 2 Provided by IHSNot for ResaleNo repr

10、oduction or networking permitted without license from IHS-,-,-A-A-50638 7777Y OLb2075 056 A-A-50 6 18 8. Cyclinq. The battery shall be capable of 270 cycles minimum. The cycles shall consist of any combination of the requirements listed in paragraphs 5 and 7 with a minimum of 80% capacity at the spe

11、cified rate. At least one cycle of each capacity check listed in paragraph 5 shall be conducted for verification. Only cycles yielding 80% or greater capacity are to be counted. Charging shall be conducted with a constant potential charger set at 7.05 volts with a limiting current of 45 amperes. 9.

12、Each battery shall be provided with a lifting device or system to facilitate manual or mechanical handling. 10. Bid samples. When specified in the solicitation, bid samples shall be furnished. Contractor Certification. The contractor shall certify and maintain substantiating evidence that the produc

13、t offered meets the salient characteristics of this Commercial Item Description, and that the product conforms to the producers own drawings, specifications, standards and quality assurance practices. The government reserves the right to require proof of such conformance prior to first delivery and

14、thereafter as may be otherwise provided for under the provisions of the contract. Metric Products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units, provided they fall within specified tolerances using conversion tables co

15、ntained in the latest revision of Federal Standard No. 376 and all other requirements of this Commercial Item Description are met. If a product is manufactured to metric dimensions, the dimensions and tolerances shall not exceed those specified in the inch-pound units, and overall outside dimensions

16、 shall remain equal to or less than those stated in inches. The contracting officer has the option of accepting or rejecting the product. Requlatory Requirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practicable. S

17、afety. A Material Safety Data Sheet (MSDS) is required in accordance with Code of Federal Regulations, 29 CFR 1910-1200 and FED-STD-313. a 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-50bLB = 9999974 01ib207b T92 A-A-5 O 6 18 Preservation, D

18、ackaqinq, p ackinq, labelinq and markinq. The preservation, packaging, packing, labeling and marking shall be as specified in the contract or order. Notes. Purchaser should specify voltage, ampere-hours and size if bid samples are required. FED-STD-376 is available from the Standardization Documents

19、 Order Desk, 700 Robbins Avenue, Building #4, Section D, Philadelphia, PA 19111-5094. Potential sources. Based on information available at the time this document was developed, the following products are believed to comply with the salient characteristics of this Commercial Item Description. Competi

20、tion is not limited to the indicated sources. Manufacturer Manufacturers battery code MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITIES Military Coordinatinq Activity Navy - SH Custodian Army - ER Air Force - 99 Navy - SH Review GSA - FSS PREPARING ACTIVITY: NAVY - SH PROJECT 6140-0749 Army - AV, MI, AT Air Force - 11, 80 Navy - AS DLA - GS 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1