NAVY MIL-DTL-24643 54 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS8NW-6《LS8NW-6型 -20 ℃~+90 ℃电缆》.pdf

上传人:priceawful190 文档编号:978682 上传时间:2019-03-13 格式:PDF 页数:4 大小:23.28KB
下载 相关 举报
NAVY MIL-DTL-24643 54 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS8NW-6《LS8NW-6型 -20 ℃~+90 ℃电缆》.pdf_第1页
第1页 / 共4页
NAVY MIL-DTL-24643 54 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS8NW-6《LS8NW-6型 -20 ℃~+90 ℃电缆》.pdf_第2页
第2页 / 共4页
NAVY MIL-DTL-24643 54 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS8NW-6《LS8NW-6型 -20 ℃~+90 ℃电缆》.pdf_第3页
第3页 / 共4页
NAVY MIL-DTL-24643 54 F-2009 CABLE ELECTRICAL -20 DEGREE C TO +90 DEGREE C TYPE LS8NW-6《LS8NW-6型 -20 ℃~+90 ℃电缆》.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MIL-DTL-24643/54F 1 October 2009 SUPERSEDING MIL-DTL-24643/54E 22 August 2002 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS8NW-6 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the

2、 product described herein shall consist of this specification sheet and MIL-DTL-24643. Construction, Non-Watertight First - Copper conductor, coated or uncoated 12 AWG, class B stranding, ASTM B8. Second - Separator may be used at manufacturers option where required to provide free-stripping insulat

3、ion. Third - Thermoset insulation with 0.030 inch minimum average thickness. Standard identification code shall be applied by Method 1 or Method 3. If Method 1 is used, the insulation color shall be black. Fourth - Eight conductors cabled together with a lay in accordance with 3.4.4 of MIL-DTL-24643

4、 Fillers may be used as necessary to form a firm well-rounded assembly. Fifth - An optional binder. Sixth - Cross-linked polyolefin jacket. Minimum average wall thickness of 0.040 inch. Maximum overall cable diameter 0.670 inch. NOTE: LS8NW-6 military part number M24643/54-01UN. AMSC N/A FSC 6145 P

5、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/54F REQUIREMENTS: Qualification required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) 1.72 Voltage withstand (volts, root mean square, min.) Conductor

6、 to conductor 4000 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 4200 Conductor continuity No failure Group A: Visual and dimensional No failure Group B: Cold bending cable No failure Thermoset proof test (percent, max.) Insulation 50 Jacket (when tested at 200 C) 50 Physica

7、ls (unaged) Insulation (extruded) Tensile strength (lb/in2, min.) 700 Elongation (percent, min.) 150 Jacket (cable) Tensile strength (lb/in2, min.) 1300 Elongation (percent, min.) 160 Tear (lb/in thickness, min.) 35 Group C: Physicals (aged) air oven Insulation (extruded) Tensile strength (percent o

8、f unaged, min.) 75 Elongation (percent of unaged, min.) 75 Jacket (cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/54F Permanence of printing

9、 (conductor), Method 1 only (cycles, min.) 25 Permanence of printing (jacket) (cycles, min.) 125 Heat distortion (percent of unaged, max.) 30 Shrinkage No failure Group D: Flame propagation (cable) No failure Qualification Inspection: Qualification inspection shall include basic electricals; groups

10、A, B, C, and D; plus the following: Cold working (minus 202 C) No damage Aging and compatibility (cable) (1255 C) No failure Abrasion resistance (jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket 2 Fillers 2 Insulation 18Halogen content (percent, max.) Jacket 0.2 Fillers 0.2Insul

11、ation 0.2 Immersion (jacket) Tensile strength (percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index (max.) Jacket 25 Fillers 45Insulation 45 Toxicity index (max.) Jacket 5 Fillers 5Insulation 1.5Durometer (jacket) - Type A (hardness, min.) 80 Weathering (jacket) No failure

12、 Electrical moisture absorption No failure 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/54F 4 UNIT ORDERING LENGTHS: Type and size Feet (nominal) LS8NW-6 2000 CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this rev

13、ision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army MI Navy SH Navy SH (Project 6145-2008-058) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • EN 12697-26-2012 en Bituminous mixtures - Test methods for hot mix asphalt - Part 26 Stiffness《热拌沥青沥青混合物-测试方法- 26部分 刚度》.pdf EN 12697-26-2012 en Bituminous mixtures - Test methods for hot mix asphalt - Part 26 Stiffness《热拌沥青沥青混合物-测试方法- 26部分 刚度》.pdf
  • EN 12697-26-2018 en Bituminous mixtures - Test methods - Part 26 Stiffness.pdf EN 12697-26-2018 en Bituminous mixtures - Test methods - Part 26 Stiffness.pdf
  • EN 12697-27-2000 Bituminous Mixtures - Test Methods for Hot Mix Asphalt - Part 27 Sampling《沥青混合料 热拌合沥青试验方法 第27部分 取样》.pdf EN 12697-27-2000 Bituminous Mixtures - Test Methods for Hot Mix Asphalt - Part 27 Sampling《沥青混合料 热拌合沥青试验方法 第27部分 取样》.pdf
  • EN 12697-27-2017 en Bituminous mixtures - Test methods - Part 27 Sampling.pdf EN 12697-27-2017 en Bituminous mixtures - Test methods - Part 27 Sampling.pdf
  • EN 12697-28-2000 en Bituminous Mixtures - Test Methods for Hot Mix Asphalt - Part 28 Preparation of Samples for Determining Binder Content Water Content and Grading《沥青混合物 热混合沥青的试验方.pdf EN 12697-28-2000 en Bituminous Mixtures - Test Methods for Hot Mix Asphalt - Part 28 Preparation of Samples for Determining Binder Content Water Content and Grading《沥青混合物 热混合沥青的试验方.pdf
  • EN 12697-29-2002 en Bituminous mixtures - Test methods for hot mix asphalt - Part 29 Determination of the dimensions of a bituminous specimen《沥青混合物 热混合沥青的试验方法 第29部分 沥青样品尺寸的测定》.pdf EN 12697-29-2002 en Bituminous mixtures - Test methods for hot mix asphalt - Part 29 Determination of the dimensions of a bituminous specimen《沥青混合物 热混合沥青的试验方法 第29部分 沥青样品尺寸的测定》.pdf
  • EN 12697-3-2013 en Bituminous mixtures - Test methods for hot mix asphalt - Part 3 Bitumen recovery Rotary evaporator《沥青混合物 热沥青混合物试验方法 第3部分 沥青回收 旋转蒸发器》.pdf EN 12697-3-2013 en Bituminous mixtures - Test methods for hot mix asphalt - Part 3 Bitumen recovery Rotary evaporator《沥青混合物 热沥青混合物试验方法 第3部分 沥青回收 旋转蒸发器》.pdf
  • EN 12697-30-2012 en Bituminous mixtures - Test methods for hot mix asphalt - Part 30 Specimen preparation by impact compactor《沥青混合料 热混沥青的试验方法 第30部分 冲击压实机的样品制备》.pdf EN 12697-30-2012 en Bituminous mixtures - Test methods for hot mix asphalt - Part 30 Specimen preparation by impact compactor《沥青混合料 热混沥青的试验方法 第30部分 冲击压实机的样品制备》.pdf
  • EN 12697-31-2007 en Bituminous mixtures - Test methods for hot mix asphalt - Part 31 Specimen preparation by gyratory compactor《沥青混合物 热混合沥青的试验方法 第31部分 用旋转式压实机的试样制备》.pdf EN 12697-31-2007 en Bituminous mixtures - Test methods for hot mix asphalt - Part 31 Specimen preparation by gyratory compactor《沥青混合物 热混合沥青的试验方法 第31部分 用旋转式压实机的试样制备》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1