1、 INCH-POUND MIL-DTL-24643/65A 28 January 2010 SUPERSEDING MIL-DTL-24643/65 1 March 2007 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, TYPE LS3C179DT (INCLUDING VARIATION LS6C179DT) This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements f

2、or acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24643. This cable can be manufactured in two variations: LS3C179DT (three internal coaxial cables) and LS6C179DT (six internal coaxial cables). Construction (Non-Watertight) First - Copper conductor, coat

3、ed or uncoated, in accordance with ASTM B286, 0.0122-inch diameter. Second - Thermoset insulation, diameter 0.056 inch nominal. Third - Light bonded aluminum foil-polyester tape, aluminum foil shield. Foil in contact with braid. Fourth - Braided shield of 38 AWG tin-coated copper: minimum coverage 9

4、5 percent, diameter 0.079 inch nominal. Fifth - Cross-linked polyolefin jacket. Diameter 0.1000.005 inch. Sixth - The required number of coaxial cables cabled together with a lay in accordance with 3.4.9 of MIL-DTL-24643. Fillers may be used as necessary to make a firm, well-rounded assembly. Sevent

5、h - An optional binder. Eighth - Tinned copper braid, 36 gauge, 90 percent coverage. Ninth - Cross-linked polyolefin jacket. Minimum thickness of 0.040 inch. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/65A TABLE I.

6、 Details. Overall diameter (inches) Military part no. M24643/65 Size Number of coaxes Diameter over shield (inches nominal) Cable jacket thickness min. avg. (inches) Min. Max. Cold bend mandrel diameter (inches) -01UO 3 3 0.240 0.047 0.335 0.365 4.0 -02UO 6 6 0.325 0.050 0.425 0.455 5.0 REQUIREMENTS

7、 Qualification Required. INSPECTION: Basic Electricals: Conductor resistance (ohms/1000 feet at 25 C, max.) 110 Voltage withstand (volts, root mean square, min.) Conductor to conductor 2000 Conductor to shield 1000 Insulation resistance (megohms/1000 feet, min.) Conductor to conductor 500 Conductor

8、 to shield 500 Jacket flaws No failure Conductor and shield continuity No failure Group A: Visual and dimensional No failure Characteristic impedance (ohms) 755 (TDR method in accordance with characteristic impedance of MIL-DTL-17) Group B: Thermoset proof test (percent, max.) Overall jacket 50 Cold

9、 bending, cable mandrel diameter 12 times cable diameter No damage Bending endurance (at 25+2 C, cycles, min.) 25 Tear (lb/in thickness, min.) (ASTM D470) 35 Physicals (unaged) Insulation Tensile strength (lb/in2, min.) 600 2 Provided by IHSNot for ResaleNo reproduction or networking permitted witho

10、ut license from IHS-,-,-MIL-DTL-24643/65A Elongation (percent, min.) 200 Jacket (component) Tensile strength (lb/in2, min.) 1000 Elongation (percent, min.) 100 Jacket (cable) Tensile strength (lb/in2, min.) 1300 Elongation (percent, min.) 160 Group C: Physicals (aged) (air oven) Insulation Tensile s

11、trength (percent of unaged, min.) 80 Elongation (percent of unaged, min.) 80 Jacket (components) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Jacket (cable) Tensile strength (percent of unaged, min.) 60 Elongation (percent of unaged, min.) 60 Shrinkage No fai

12、lure Heat distortion (percent of unaged, max.) 30 Permanence of printing (jacket) (cycles, min.) 125 Group D: Flame propagation (cable) No failure Qualification Inspection: Qualification inspection shall include basic electricals; groups A, B, C, and D; plus the following: Aging stability (cable) (9

13、82 C) No failure (Test in accordance with aging stability of MIL-DTL-17) Dimensional stability (cable) (852 C) No failure (Test in accordance with dimensional stability of MIL-DTL-17) Abrasion resistance (overall jacket) (scrapes, min.) 75 Acid gas equivalent (percent, max.) Jacket (component and ov

14、erall) 2 Fillers 2 Insulation 183 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24643/65A 4 Shield insulation 2 Halogen content (percent, max.) Jacket (component and overall) 0.2 Fillers 0.2Insulation 0.2Immersion (jacket) Tensile strength

15、percent of unaged, min.) 50 Elongation (percent of unaged, min.) 50 Smoke index, max. Jacket (component and overall) 25 Fillers 45Insulation 45 Toxicity index, max. Jacket (component and overall) 5 Fillers 5Insulation 1.5Durometer (overall jacket) Type A (hardness, min.) 80 Weathering (overall jack

16、et) No failure UNIT ORDERING LENGTHS: Type and size Feet (nominal) LS3C179DT, LS6C179DT All sizes 500 CHANGES FROM PREVIOUS ISSUE: Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity:

17、 Army MI Navy SH Navy SH (Project 6145-2009-108) Review Activities: Army AR, AV, CR Navy CG, EC DLA CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ANSI ISO IEC 9995-2-1994 Information technology - Keyboard layouts for text and office systems - Part 2 Alphanumeric section (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第2部分 INCITS采纳的字母数.pdf ANSI ISO IEC 9995-2-1994 Information technology - Keyboard layouts for text and office systems - Part 2 Alphanumeric section (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第2部分 INCITS采纳的字母数.pdf
  • ANSI ISO IEC 9995-4-1994 Information technology - Keyboard layouts for text and office systems - Part 4 Numeric section (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第4部分 INCITS采纳的数字集》.pdf ANSI ISO IEC 9995-4-1994 Information technology - Keyboard layouts for text and office systems - Part 4 Numeric section (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第4部分 INCITS采纳的数字集》.pdf
  • ANSI ISO IEC 9995-5-1994 Information technology - Keyboard layouts for text and office systems - Part 5 Editing section (Adopted by INCITS)《信息技术.文本和办公系统的键盘布局.第5部分 INCITS采纳的编辑部分》.pdf ANSI ISO IEC 9995-5-1994 Information technology - Keyboard layouts for text and office systems - Part 5 Editing section (Adopted by INCITS)《信息技术.文本和办公系统的键盘布局.第5部分 INCITS采纳的编辑部分》.pdf
  • ANSI ISO IEC 9995-6-1994 Information technology - Keyboard layouts for text and office systems - Part 6 Function Section (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第6部分 INCITS采纳的功能部分》.pdf ANSI ISO IEC 9995-6-1994 Information technology - Keyboard layouts for text and office systems - Part 6 Function Section (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第6部分 INCITS采纳的功能部分》.pdf
  • ANSI ISO IEC 9995-7-1994 Information technology - Keyboard layouts for text and office systems - Part 7 Symbols used to represent functions (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第7.pdf ANSI ISO IEC 9995-7-1994 Information technology - Keyboard layouts for text and office systems - Part 7 Symbols used to represent functions (Adopted by INCITS)《信息技术.文本和办公系统用键盘布局.第7.pdf
  • ANSI ISO IEC 9995-8-1994 Information technology - Keyboard layouts for text and office systems - Part 8 Allocation of letters to the keys of a numeric keypad (Adopted by INCITS)《信息.pdf ANSI ISO IEC 9995-8-1994 Information technology - Keyboard layouts for text and office systems - Part 8 Allocation of letters to the keys of a numeric keypad (Adopted by INCITS)《信息.pdf
  • ANSI IT1.80-1995 Photography (Photofinishing) - Identification of Customer Order Components for Automatic Matching in a Centralized Photofinishing Plant《摄影(冲洗胶卷).集中冲洗胶卷设备中自动匹配用客户订购.pdf ANSI IT1.80-1995 Photography (Photofinishing) - Identification of Customer Order Components for Automatic Matching in a Centralized Photofinishing Plant《摄影(冲洗胶卷).集中冲洗胶卷设备中自动匹配用客户订购.pdf
  • ANSI IT10.2000-2004 Photography Digital Still Cameras JPEG 2000 DSC Profile《摄影.数码相机.JPEG 2000动态稳定控制系统轮廓》.pdf ANSI IT10.2000-2004 Photography Digital Still Cameras JPEG 2000 DSC Profile《摄影.数码相机.JPEG 2000动态稳定控制系统轮廓》.pdf
  • ANSI IT10.7000-2004 Photography Digital Still Cameras Guidelines for Reporting Pixel-Related Specifications《摄影.数码相机.报告像素相关规范用指南》.pdf ANSI IT10.7000-2004 Photography Digital Still Cameras Guidelines for Reporting Pixel-Related Specifications《摄影.数码相机.报告像素相关规范用指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1