1、AMSC N/A FSC 6645 INCH-POUND MIL-DTL-7793/3B 19 October 2012 SUPERSEDING MIL-M-7793/3A 15 September 1988 DETAIL SPECIFICATION SHEET METER, TIME TOTALIZING, MINIATURE, DIGITAL, 115 V, 60 Hz, SQUARE This specification is approved for use by all Departments and Agencies of the Department of Defense. Re

2、activated after 19 October 2012 and may be used for new and existing designs and acquisitions. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-7793. FIGURE 1. Meter configuration. Terminal Location Optional .166 .146 1.000 .125 DIA 2

3、HOLES 1.094 1.047.445 .425 .235 .173 .87 .06 .030 DIA WIRE .06 ID HOOK TERMINAL1.31 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/3B 2 REQUIREMENTS: 1. Dimensions. Dimensions are in inches. Unless otherwise specified, tolerances are .0

4、2 for two-place decimals and .015 for three-place decimals. 2. Mounting flange. Meters with fixed flanges shall be tin plated on the front surface of the mounting flange in accordance with ASTM-B545 to provide an electrical ground for the case. In accordance with Table I, meters may be furnished wit

5、h no flange or with adjustable split mount flanges in accordance with MS3345-2. 3. Life accuracy. Meter accuracy shall be 0.1 percent from -85 to 257 F (-65 to 125 C) and 100 to 130 VAC at 60 Hz. 4. Frequency rating. The meter shall operate satisfactorily and maintain accurately the life accuracy li

6、mits as specified above over the frequency range of 50 to 70 Hz (see Note 1). 5. Power consumption. The average power consumption at 115 volts alternating current (VAC), 60 Hz shall not exceed 0.3W. 6. Operating temperature range. The operating temperature range shall be from -85 to 257 F (-65 to 12

7、5 C). 7. Time range. Total readout of the meters shall be 9999 hours. 8. Transient protection. No temporary or permanent degradation shall be produced in the meter if the input voltage should increase to 180V rms at 50 to 70 Hz for a period of 150 milliseconds maximum. 9. Voltage range. The operatin

8、g voltage shall be from 100 to 130 VAC. 10. Weight. Weight shall be not greater than 0.6 ounce with flange 11. Dielectric strength test voltages. The dielectric test voltages shall be 350 V root mean square (rms) at altitude specified in MIL-DTL-7793 and 600 V rms at room ambient temperature (approx

9、imately 25 C) and pressure. 12. Qualification tests. Qualification tests shall be conducted in accordance with MIL-DTL-7793, except that the life accuracy, dielectric strength test voltages, operating temperature range, dielectric strength test voltages and life accuracy shall be as specified herein

10、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7793/3B 3 NOTE: 1. Accuracy is degraded at the same percent as the percentage change in the input frequency range from 60 Hz, plus the specified accuracy tolerance. TABLE I. Dimension A of fla

11、nge on figure 1. Military Part Number Flange Data Dim A .015 Military Part Number Flange Data Dim A .015 M7793/3-001 Adjustable per MS3345-1 M7793/3-015 .375 M7793/3-002 No Flange M7793/3-016 .406 M7793/3-003 .000 (Flush) M7793/3-017 .438 M7793/3-004 .031 M7793/3-018 .469 M7793/3-005 .062 M7793/3-01

12、9 .500 M7793/3-006 .094 M7793/3-020 .531 M7793/3-007 .125 M7793/3-021 .562 M7793/3-008 .156 M7793/3-022 .594 M7793/3-009 .188 M7793/3-023 .625 M7793/3-010 .218 M7793/3-024 .656 M7793/3-011 .250 M7793/3-025 .688 M7793/3-012 .281 M7793/3-026 .719 M7793/3-013 .312 M7793/3-027 .750 M7793/3-014 .344 M779

13、3/3-028 .781 13. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Referenced documents. In addition to MIL-DTL-7793, this specification sheet references MS3345 and ASTM-B545. Custodi

14、ans: Preparing activity: Army - AR Navy - AS Navy - AS (Project 6645-2012-005) Air Force - 99 Review activity: DLA GS1 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM D3936-2005 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering《绒头纱线地板覆盖物的第二层背衬耐脱层性的标准试验方法》.pdf ASTM D3936-2005 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering《绒头纱线地板覆盖物的第二层背衬耐脱层性的标准试验方法》.pdf
  • ASTM D3936-2011 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering《绒头纱线地毯二次背衬剥离电阻的标准试验方法》.pdf ASTM D3936-2011 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering《绒头纱线地毯二次背衬剥离电阻的标准试验方法》.pdf
  • ASTM D3936-2012 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering 《绒头纱线地毯二次背衬剥离电阻的标准试验方法》.pdf ASTM D3936-2012 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering 《绒头纱线地毯二次背衬剥离电阻的标准试验方法》.pdf
  • ASTM D3936-2017 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering《簇绒地毯第二层底布的脱层强度的测试方法》.pdf ASTM D3936-2017 Standard Test Method for Resistance to Delamination of the Secondary Backing of Pile Yarn Floor Covering《簇绒地毯第二层底布的脱层强度的测试方法》.pdf
  • ASTM D3937-2007 Standard Test Method for Crimp Frequency of manufactured Staple Fibers《纺纱用人造短纤维卷曲率的标准试验方法》.pdf ASTM D3937-2007 Standard Test Method for Crimp Frequency of manufactured Staple Fibers《纺纱用人造短纤维卷曲率的标准试验方法》.pdf
  • ASTM D3937-2012 Standard Test Method for Crimp Frequency of Manufactured Staple Fibers 《人造短纤维卷曲率的标准试验方法》.pdf ASTM D3937-2012 Standard Test Method for Crimp Frequency of Manufactured Staple Fibers 《人造短纤维卷曲率的标准试验方法》.pdf
  • ASTM D3937-2012(2018) Standard Test Method for Crimp Frequency of Manufactured Staple Fibers.pdf ASTM D3937-2012(2018) Standard Test Method for Crimp Frequency of Manufactured Staple Fibers.pdf
  • ASTM D3938-2007 Standard Guide for Determining or Confirming Care Instructions for Apparel and Other Textile Products《服装和其他纺织品用确定或确认标签用法的标准指南》.pdf ASTM D3938-2007 Standard Guide for Determining or Confirming Care Instructions for Apparel and Other Textile Products《服装和其他纺织品用确定或确认标签用法的标准指南》.pdf
  • ASTM D3938-2013 Standard Guide for Determining or Confirming Care Instructions for Apparel and Other Textile Products《服装和其他纺织品用确定或确认标签用法的标准指南》.pdf ASTM D3938-2013 Standard Guide for Determining or Confirming Care Instructions for Apparel and Other Textile Products《服装和其他纺织品用确定或确认标签用法的标准指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1