1、-3 MIL-P-82866 13 = 999990b 0473900 5 I INCH-POUND I MIL-P-82866(0S) 27 March 1991 SUPERSEDING WS 13643A 18 June 1979 MILITARY SPECIFICATION PRIMER, ELECTRIC, MARK 153 MOD 1 This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by a

2、ll Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification establishes the minimum requirements for the Electric Primer, Mark 153 Mod 1, herein referred to as the “primer.“ 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The

3、 following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards ODISS) and supplement thereto, cited in the

4、solicitation (see 6.2). SPECIFICATIONS FEDERAL PPP-B-636 Boxes, Shipping, Fiberboard MILITARY MIL-D-3464 Desiccants, Activated, Bagged, Packaging Use and Static Dehumidification Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this d

5、ocument should be addressed to: Commanding Officer, Naval Ordnance Station, Standardization Branch (Code 3730), Indian Head, MD 20640-5000 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or sending a letter. AMSC NIA DISTRIBUTION STATEM

6、ENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-828bb 13 W 9999906 0473901 7 W MIL-P-82866(OS) STANDARDS MILITARY MIL-STD-129 Marking for Shipment and Storage MIL-STD-33 1 Fuze and

7、Fuze Components, Environmental and Performance Tests for MIL-STD-453 Inspection, Radiographic MIL-STD-1167 Amunition Data Card MIL-STD-1168 Ammunition Lot Numbering DOD-STD-2101 Classification of Characteristics (Unless otherwise indicated, copies of federal and military specifications and military

8、standards are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to th

9、e extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWINGS NAVAL SEA SYSTEMS COMMAND (CAGE CODES 10001 AND 5371 1) 2847639 Primer, Electric, Mark 153 Mod 1 50 12985 Charge, Propelling, 5-Inch, 54 Caliber, Reduced, Mark 68 Mod 2 5166058 Pack, Prime

10、r, MK 43 Mod 1, Primers for Gun Cartridges, 5-Inch and Larger 5 166059 Shipping Condition, Primer for Gun Cartridges, 5-Inch and Larger in Pack, Primer, Mk 43 Mod 1 (Application for copies of NAVSEA drawings should be addressed to: Commanding Officer, Naval Ordnance Station, Attn; Code 802, Louisvil

11、le, KY 40214.) PUBLICATIONS NAVAL SEA SYSTEMS COMMAND (CAGE CODE 10001) OD 49540 Functioning Test of Electric Primers 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-z -. MIL-P-828bb 13 m 99999Ob 0473902 9 m - r- MIL-P-82866(OS) (Application for co

12、pies of ODs should be addressed to: Commanding Officer, Naval Ship Weapons Systems Engineering Station, NAVSEA Data Support Activity (Code 5H30), Port Hueneme, CA 93043 .) “R-531884 Palletizing Domestic Unit Load (Application for copies of WRs should be addressed to: Commanding Officer, Naval Public

13、ations and Forms Center, (ATN: PODS), 5801 Tabor Avenue, Philadelphia, PA 19120-5099.) CODE OF FEDERAL REGULATIONS (CFR) 49 CFR 100-199 Transportation me Code of Federal Regulations is available from the Superintendent of Documents, US Government Printing Office, Washington, DC 20402.) 2.2 Order of

14、precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First

15、 article. When specified (see 6.2), a sample shall be subjected to first article inspection (see 6.4) in accordance with 4.4. 3.2 Characteristics. The primer shall conform to all requirements specified herein and on Drawing 2847639 and associated documents. *e 3.3 Radiographic (M101). The primer sha

16、ll not exhibit any discernible gaps as identified in figure 1 (see 4.7.1 1. Gap no. 3 FIGURE 1. GaD identification. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.4 Black powder moisture content (M102). The moisture content of the black powder w

17、ithin the primer shall not exceed 0.70 percent by weight (see 4.7.2). 3.5 Detail strip. The primer and ail its components shall conform to the following requirements (see 4.7.3): a. (Ci) Each criticai.characteristic shall be as specified in the applicable documents listed on Drawing 2847639 and in t

18、his specification. b. (M103) Each major characteristic shall be as specified in the applicable documents listed on Drawing 2847639 and in this specification. 3.6 Electrical resistance (M104). The primer shall have an electrical resistance of O. 10 to O. 18 ohm (see 4.7.4), 3.7 Functional. The primer

19、 shall meet the following criteria (see 4.7.5): a. (M105) Primer functioning time shall be a maximum of 0.006 second; b. (M106) The primer shall not misfire (see 6.7.1); c. (M107) The primer shall not exhibit blowback (see 6.7.2); and d. (C2) The primer shall not exhibit a split stock, split tube, o

20、r detachment of metallic components other than blowout of ignition element closing discs. 3.8 Vibration, The primer shall meet the following requirements (see 4.7.6): a. (C3) The primer shall not function during vibration; b. (C4) The stock and tube shall maintain material integrity and the primer s

21、hall maintain assembly integrity at the mating threads of the stock and tube during vibration; c. (M108) The primer shall not otherwise physically breakdown during vibration; d. The primer shall meet the requirements of 3.6 after vibration; and e. The primer shall meet the requirements of 3.7 after

22、vibration. 3.9 Ballistics. The primer when assembled into a 5“/54 propelling charge shall provide ignition which will meet the criteria of 3.7 b., c., and d. and the following (see 4.7.7): a. (M109) The ejection time of the projectile from the gun barrel shall not be greater than 0.050 second after

23、application of firing energy. 4 MIL-P-828bb 13 m 999990b 0473903 O m 3 I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. r -. MIL-P-828bb 13 M 777770b 0473704 2 = 3.10 Workmanship. All parts shall be free of chips, dirt, grease, rust, and all other

24、 foreign material. There shall be no burrs or other imperfections of manufacture which would affect the assembly, functioning, or handling of the product. The cleaning methods used shall not be injurious to any of the parts, nor shall the parts be contaminated by the cleaning agents. All markings sh

25、all be legible. 0 4. QUALITY ASSURANCE PROVISIONS 4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements (examinations and tests) as specified herein. Except as otherwise specif

26、ied in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in this spec

27、ification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.1.1 Responsibility for compliance. All items must meet all requirements of sections 3 and 5. The inspection set forth in this specification shall become a part of the contracto

28、rs overall inspection system or quality program. The absence of any inspection requirements in the specification shall not relieve the contractor of the responsibility of ensuring that ail products or supplies submitted to the Government for acceptance comply with all requirements of the contract. S

29、ampling inspection, as part of manufacturing operations, is an acceptable practice to ascertain conformance to requirements, however, this does not authorize submission of known defective material, either indicated or actual, nor does it commit the Government to accept defective material. 4.2 Classi

30、fication of inspections. The inspection requirements specified herein are classified as . follows: - a. b. First article inspection (see 4.4) Quality conformance inspection (see 4.5) 4.3 Test and examination methods (see 6.2). Primers shall be selected at random for each test or examination. Identif

31、ication of each primers complete test and examination results shall be secured for additional examination until otherwise directed by the contracting activity (see 6.6). 4.4 First article inspection. The first article shall be a homogeneous sample of 130 assembled primers and five each of every comp

32、onent part and subassembly (less explosive components) fabricated, packaged, and packed in accordance with the requirements of this specification and the contract or purchase order using the methods and procedures to be used for production. The first article shall be submitted to the facility design

33、ated in the contract or order for testing in accordance with the first article inspection plan of table I (see 6.2 and 6.4). 4.4.1 First article sample rejection. Failure of the first article sample to meet any of the requirements shall be cause for rejection of the sample. 5 Provided by IHSNot for

34、ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-Zbb 13 9999906 0473905 4 44 4- O0 oc O000 W vi 44 O0 W vi c? 2. v! m O0 oc O000 O m 9 2 v! 2 6 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. MIL-P-8Zbb 13 = 99999Ob

35、0473906 b 4.5 Quality conformance inspection. 4.5.1 Lot formation. Unless otherwise specified in the contract or purchase order (see 6.2), production lots shall consist of not more than 20,000 homogeneous primers plus those required for inspection (see 4.5.2). Each production lot shall contain only

36、one Class 2 black powder lot and one Class 4 black powder lot and only one tubing heat treat lot. O 4.5.2 Inspection. Unless otherwise specified in the contract or purchase order (see 6.2), 105 samples shall be selected at random from each production lot for testing in accordance with the quality co

37、nformance inspection plan of table 1. 4.6 Classification of characteristics, The characteristics verified by the tests and examination herein are classified as critical, major, or minor in accordance with DOD-STD-2101. Requirements for critical characteristics are identified by the symbol (C) and ma

38、jor characteristics by the symbol (M). The number following the classification symbol indicates the serial number of the characteristic. Requirements which are not annotated with a classification code are classified as minor. 4.7 Methods of inspection. 4.7.1 Radiographic. The primer shall be subject

39、ed to a radiographic inspection in accordance with MIL-STD-453. The primer shall be mounted in the vertical position with the prima stock up and X-rayed perpendicular to its axis, focused at a point 0.6 b. Phase II: Primer axis vertical, primer stock down; c. Phase III: Primer axis vertical, primer

40、stock up. The primer shall be marked with a line in the axial direction at the junction of the stock and tube indexing their initial relative position, in order to determine the integrity after vibration. The primer shall be rigidly mounted to the vibration table at the primer stock. After vibration

41、, the primer shall be subjected to the tests of 4,7,4 and 4.7.5. 4.7.7 Ballistics. The primer shall be assembled into 5“/54 caliber reduced service propelling charge assembly in accordance with Drawing 5012985. All components shall be from service acceptable lots. The propellant shall be conditioned

42、 at 90 & 15F for 24 hours minimum prior to- assembly of the propelling charge, All other components shall be conditioned at 85 & 20F for 24 hours minimum prior to assembly of the propelling charge. The assembled propelling charge shall be conditioned at 90 & 5F for 48 hours minimum immediately prior

43、 to firing. Serviceable blind, loaded, and plugged projectiles 8 e . a Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-82bb 13 W 999790b 0473908 T W MIL-P-82866(0S) shall be used. The rounds shall be fired in a 5“154 caliber electrically fired

44、gun with a first quarter life barrel. Prjectile ejection time shall be recorded. 0 4.7.8 Inspection of packaging. The packaging, packing, and marking shall be visually examined for conformance to section 5. 5. PACKAGING 5.1 Packaging (Level A). The primer shall be packaged in Primer Pack, Mk 43 Mod

45、1, Drawing 5166058. 5.1.1 Inert components. Components and subassemblies shall be packaged in commercial fiberboard containers meeting the requirements of PPP-B-636. Each container shall incorporate corrugated or solid fiberboard dividers or collars suitable for preventing damage in handling and tra

46、nsportation, The gross weight of the container contents shall not be greater than 70 pounds. Fifty-six units of desiccant, conforming to Type I of MIL-D-3464, shall be placed in each container prior to securing the cover. 5.2 Packing (Level A). Primers packaged in accordance with 5.1 shall be packed

47、 in accordance with Drawing 5166059. 5.3 Palletization. Palletization of primers packed in accordance with 5.2 shall be in accordance with WR-53 I8 84 5.4 Marking. In addition to any special marking required by the contract or purchase order (see 6.2), all markings shall be in accordance with MIL-ST

48、D-129 and 49 CFR 171-178. 5.5 Ammunition data cards. When specified in the contract or purchase order (see 6,2), one ammunition data card prepared in accordance with MIL-STD-1167 shall be placed in the top of each pack (see 5. i), five shall be forwarded to the contracting activity, and twenty shall

49、 go to the ammunition depot receiving the primers. For the Navy acquisitions, two data cards shall also go to each of the activities listed in 6.6 (see 6.3). 5.6 Ammunition lot number. Ammunition lot number shall be in accordance with MIL-STD-1168. 6. NOTES mis section contains information of a general or explanatory nature that may be helpful, but is not mandatory). 6.1 Intended Use. The Mk 153 Mod 1 Electric Primer is