NAVY MIL-PRF-18148 1-2009 PLUG ELECTRIC TWO-WIRE AIRCRAFT STORAGE BATTERY [Superseded DLA MS3349 REV C NOTICE 1 DLA MS3349 REV C DLA MS3349 REV B DLA MS3349 REV A DLA MS3349]《飞机蓄电池.pdf

上传人:outsidejudge265 文档编号:980897 上传时间:2019-03-12 格式:PDF 页数:6 大小:64.51KB
下载 相关 举报
NAVY MIL-PRF-18148 1-2009 PLUG ELECTRIC TWO-WIRE AIRCRAFT STORAGE BATTERY [Superseded DLA MS3349 REV C NOTICE 1 DLA MS3349 REV C DLA MS3349 REV B DLA MS3349 REV A DLA MS3349]《飞机蓄电池.pdf_第1页
第1页 / 共6页
NAVY MIL-PRF-18148 1-2009 PLUG ELECTRIC TWO-WIRE AIRCRAFT STORAGE BATTERY [Superseded DLA MS3349 REV C NOTICE 1 DLA MS3349 REV C DLA MS3349 REV B DLA MS3349 REV A DLA MS3349]《飞机蓄电池.pdf_第2页
第2页 / 共6页
NAVY MIL-PRF-18148 1-2009 PLUG ELECTRIC TWO-WIRE AIRCRAFT STORAGE BATTERY [Superseded DLA MS3349 REV C NOTICE 1 DLA MS3349 REV C DLA MS3349 REV B DLA MS3349 REV A DLA MS3349]《飞机蓄电池.pdf_第3页
第3页 / 共6页
NAVY MIL-PRF-18148 1-2009 PLUG ELECTRIC TWO-WIRE AIRCRAFT STORAGE BATTERY [Superseded DLA MS3349 REV C NOTICE 1 DLA MS3349 REV C DLA MS3349 REV B DLA MS3349 REV A DLA MS3349]《飞机蓄电池.pdf_第4页
第4页 / 共6页
NAVY MIL-PRF-18148 1-2009 PLUG ELECTRIC TWO-WIRE AIRCRAFT STORAGE BATTERY [Superseded DLA MS3349 REV C NOTICE 1 DLA MS3349 REV C DLA MS3349 REV B DLA MS3349 REV A DLA MS3349]《飞机蓄电池.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、 AMSC N/A FSC 5935 MIL-PRF-18148/1 30 September 2009 SUPERSEDING MS3349C 1 June 1984 PERFORMANCE SPECIFICATION SHEET PLUG, ELECTRIC, TWO-WIRE, AIRCRAFT STORAGE BATTERY This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring

2、the product described herein shall consist of this specification sheet and MIL-PRF-18148. REQUIREMENTS: 1. Part or identifying number. The part or identifying number (PIN) of the plug covered by this specification sheet shall be MS3349-2. The MS3349-2 is a two-wire electric plug used with aircraft s

3、torage batteries. 2. Dimensions and weight. The dimensions of the plug shall be as shown on figure 1. The weight of the plug shall be not greater than 0.75 pounds (see 3.12.3 of MIL-PRF-18148 and 3.12.4 as modified herein). 3. The spacing of rigid sockets shall be as shown on figure 1. Nonrigid sock

4、ets must self-align with the MS3509 series receptacle. 4. MIL-PRF-18148 variance. The plug shall comply with MIL-PRF-18148 except as follows. 4.1 Modify the following paragraphs: 3.8.2 Electrical connections. Insert after the first sentence: “Each two-wire MS3349-2 plug shall include as its electric

5、al connections two sockets with their axes vertical and in a plane parallel to the face of the receptacle. Each plug shall be usable with two 000-gauge wires conforming to SAE-AS50861/2 for type 2. Each plug shall include two wire entry holes on the bottom, through which the wires may be brought int

6、o the sockets. Each plug shall be made so that the wires shall enter it vertically and in a plane parallel to the face of the receptacle. Each plug shall be made so that the wire which enters the left wire entry hole, as viewed looking at the front (handle) face of the plug, can be connected to the

7、negative contact only, and the wire which INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHSMIL-PRF-18148/1 2 enters the right wire entry hole can be connected to the positive contact only. The plug shall be marked with “-“ and “+“ on the front,

8、back, bottom, or sides so as to identify the wires connected to the plug. The plug shall be made so that it is not possible to assemble it with any of the marking not in its proper location. Each plug shall include two setscrews for retaining the wires in the sockets that can be accessed after remov

9、ing the cover of the plug. Each plug shall include two threaded terminals for retaining the wires in the sockets. The axes of the threaded terminals shall be perpendicular to the face of the receptacle. Each threaded terminal shall include a hexagonal wrenching socket. Each plug shall include two wr

10、ench entry holes on the front face, and shall be made so that the threaded terminals can be operated by a wrench inserted in the wrench entry holes. Probe holes of .188 diameter shall be incorporated in the plug body to allow monitoring of battery voltage at battery terminal posts with voltmeter pro

11、bes when the plug is engaged with the battery receptacle. No part of the electric circuit of the plug shall be exposed except through the wire, wrench, probe, and contact entry holes.“ 3.10.1 Delete this paragraph. 3.12.4 Weight. Insert after the first sentence: “The weight of each two-wire MS3349-2

12、 plug shall be not greater than 0.75 pounds.“ VERIFICATION 1. MIL-PRF-18148 variance. The plug shall comply with MIL-PRF-18148 except as follows. 4.2 Qualification inspection. Insert after the end of the first sentence: “(see table I of the specification sheet).“ 4.3 Conformance inspection. Insert a

13、fter the end of the first sentence: “(see table I of the specification sheet).“ 4.5.5 Plug preparation procedure. Insert as a new first sentence: “Whenever electric connection must be made to the plug, two 000-gauge wires conforming to SAE-AS50861/2 for Type 2 shall be connected to the plug in accor

14、dance with 3.8.2 of MIL-PRF-18148/1.“ 6.9 Supersession data. Delete the text and insert: “Plugs PIN MS3349-1 and MS3349-3 are hereby cancelled without replacement. They were specified by MIL-P-18148 (superseded by MIL-PRF-18148) and MS3349. Connector plugs previously procured to MS3349-2 are superse

15、ded by plugs in accordance with MIL-PRF-18148/1.“ 6.10 International standardization agreement implementation. This specification implements STANAG-3660 ED.2(8). When amendment, revision, or cancellation of this specification is proposed, the preparing activity must coordinate the action with the U.

16、S. National Point of Contact for the international standardization agreement, as identified in the ASSIST database at http:/assist.daps.dla.mil. Provided by IHSNot for Resale-,-,-MIL-PRF-18148/1 3 FIGURE 1. Dimensions and configuration for PIN MS3349-2. 2.620MAX FROM FACEOF RECEPTACLE1.590 Provided

17、by IHSNot for Resale-,-,-MIL-PRF-18148/1 4 FIGURE 1. Dimensions and configuration for PIN MS3349-2 - Continued. DOUBLE THREAD, PIT OF EACH THREAD .785 INCH Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHSMIL-PRF-18148/1 5 TABLE I. Qualification inspection

18、 and conformance inspection of plugs. Qualification sample number Conformance inspection sample number Test number Examinations and tests 1 2 3 1 2 Requirement paragraph Method of inspection paragraph 1 INCOMING INSPECTION X X X X X 3.9, 3.12.1 4.5.1 2 VISUAL AND MECHANICAL INSPECTION X X X X X 3.4

19、through 3.10, 3.12.2, table II 4.5.2 3 DIMENSIONS X X 3.12.3, Reqmt 2 4.5.3 4 WEIGHT X X X X 3.12.4, Reqmt 2 4.5.4 PLUG PREPARATION X X X X X - 4.5.5 5 STRESS TESTS AT 77F X X X X X - - 5a Dielectric strength X X X X X 3.11, 3.12.5 4.5.6.1 5b Insulation resistance X X X X X 3.11, 3.12.6 4.5.7.1 5c O

20、perating torque X X X X X 3.11, 3.12.7 4.5.8.1 5d Contact resistance X X X X X 3.11, 3.12.8 4.5.9.1 6 STRESS TESTS AT -65F X - - 6a Dielectric strength X 3.11, 3.12.5 4.5.6.2 6b Insulation resistance X 3.11, 3.12.6 4.5.7.2 6c Operating torque X 3.11, 3.12.7 4.5.8.2 6d Contact resistance X 3.11, 3.12

21、8 4.5.9.2 7 STRESS TESTS AT 160F X 7a Dielectric strength X 3.11, 3.12.5 4.5.6.3 7b Insulation resistance X 3.11, 3.12.6 4.5.7.3 7c Operating torque X 3.11, 3.12.7 4.5.8.3 7d Contact resistance X 3.11, 3.12.8 4.5.9.3 8 LIFE TEST X X 3.11, 3.12.10, 3.12.7, 3.12.8 4.5.11.1, 4.5.8.1, 4.5.9.1 9 TEMPERA

22、TURE SHOCK TEST X 3.11, 3.12.11, 3.12.5, 3.12.7, 3.12.8 4.5.12, 4.5.6.1, 4.5.8.1, 4.5.9.1 10 MECHANICAL SHOCK TEST X 3.11, 3.12.12, 3.12.5 4.5.13, 4.5.6.1 11 HUMIDITY TEST X 3.11, 3.12.14, 3.12.6, 3.12.7, 3.12.8 4.5.14, 4.5.7.1, 4.5.8.1, 4.5.9.1 12 IMMERSION X 3.10, 3.11, 3.12.15, 3.12.6, 3.12.7, 3.

23、12.8 4.5.15, 4.5.7.1, 4.5.8.1, 4.5.9.1 13 SALT FOG TEST X X X X X 3.10, 3.11, 3.12.15, 3.12.6, 3.12.7, 3.12.8 4.5.16, 4.5.7.1, 4.5.8.1, 4.5.9.1 14 VIBRATION TEST X X 3.11, 3.12.13, 3.12.5, 3.12.7, 3.12.8 4.5.17.1, 4.5.6.1, 4.5.8.1, 4.5.9.1 Provided by IHSNot for Resale-,-,-MIL-PRF-18148/1 6 CONCLUDI

24、NG MATERIAL Custodians: Preparing activity: Army - AV Navy - AS Navy - AS Air Force - 85 Agent: DLA - CC Navy - SH Reviewer activities: (Project 5935-2009-157) Army - CR, MI Air Force - 99 DLA - GS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for Resale-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM D7043-2004a Standard Test Method for Indicating Wear Characteristics of Petroleum and Non-Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《定容叶轮泵中石油和非石油液压液的磨损特性指示的标准试验.pdf ASTM D7043-2004a Standard Test Method for Indicating Wear Characteristics of Petroleum and Non-Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《定容叶轮泵中石油和非石油液压液的磨损特性指示的标准试验.pdf
  • ASTM D7043-2010 5625 Standard Test Method for Indicating Wear Characteristics of Petroleum and Non-Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《指示在恒容量叶片泵中石油和非石油液压流体的耐用.pdf ASTM D7043-2010 5625 Standard Test Method for Indicating Wear Characteristics of Petroleum and Non-Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《指示在恒容量叶片泵中石油和非石油液压流体的耐用.pdf
  • ASTM D7043-2012 red 9061 Standard Test Method for Indicating Wear Characteristics of Non-Petroleum and Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《指示在恒容量叶片泵中石油和非石油液压流.pdf ASTM D7043-2012 red 9061 Standard Test Method for Indicating Wear Characteristics of Non-Petroleum and Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《指示在恒容量叶片泵中石油和非石油液压流.pdf
  • ASTM D7043-2017 red 1875 Standard Test Method for Indicating Wear Characteristics of Non-Petroleum and Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《定容式叶轮泵中非石油和石油液压液磨损特.pdf ASTM D7043-2017 red 1875 Standard Test Method for Indicating Wear Characteristics of Non-Petroleum and Petroleum Hydraulic Fluids in a Constant Volume Vane Pump《定容式叶轮泵中非石油和石油液压液磨损特.pdf
  • ASTM D7044-2004a Standard Specification for Biodegradable Fire Resistant Hydraulic Fluids《可生物降解的阻燃型液压液的标准规范》.pdf ASTM D7044-2004a Standard Specification for Biodegradable Fire Resistant Hydraulic Fluids《可生物降解的阻燃型液压液的标准规范》.pdf
  • ASTM D7044-2004a(2010) 2500 Standard Specification for Biodegradable Fire Resistant Hydraulic Fluids《生物可降解耐火液压机液体标准规范》.pdf ASTM D7044-2004a(2010) 2500 Standard Specification for Biodegradable Fire Resistant Hydraulic Fluids《生物可降解耐火液压机液体标准规范》.pdf
  • ASTM D7044-2015 5055 Standard Specification for Biodegradable Fire Resistant Hydraulic Fluids《可生物降解的阻燃型液压液的标准规格》.pdf ASTM D7044-2015 5055 Standard Specification for Biodegradable Fire Resistant Hydraulic Fluids《可生物降解的阻燃型液压液的标准规格》.pdf
  • ASTM D7045-2004 Standard Guide for Optimization of Ground Water Monitoring Constituents for Detection Monitoring Programs for RCRA Waste Disposal Facilities《RCRA废物处理设施检测监测程序用地下水监测成.pdf ASTM D7045-2004 Standard Guide for Optimization of Ground Water Monitoring Constituents for Detection Monitoring Programs for RCRA Waste Disposal Facilities《RCRA废物处理设施检测监测程序用地下水监测成.pdf
  • ASTM D7045-2004(2010) 7500 Standard Guide for Optimization of Groundwater Monitoring Constituents for Detection Monitoring Programs for RCRA Waste Disposal Facilities《RCRC垃圾清除器械、探测.pdf ASTM D7045-2004(2010) 7500 Standard Guide for Optimization of Groundwater Monitoring Constituents for Detection Monitoring Programs for RCRA Waste Disposal Facilities《RCRC垃圾清除器械、探测.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1