NAVY UFGS-12 36 00 00 20-2011 MANUFACTURED VANITIES《已加工的浴室柜》.pdf

上传人:eventdump275 文档编号:984780 上传时间:2019-03-12 格式:PDF 页数:6 大小:37.61KB
下载 相关 举报
NAVY UFGS-12 36 00 00 20-2011 MANUFACTURED VANITIES《已加工的浴室柜》.pdf_第1页
第1页 / 共6页
NAVY UFGS-12 36 00 00 20-2011 MANUFACTURED VANITIES《已加工的浴室柜》.pdf_第2页
第2页 / 共6页
NAVY UFGS-12 36 00 00 20-2011 MANUFACTURED VANITIES《已加工的浴室柜》.pdf_第3页
第3页 / 共6页
NAVY UFGS-12 36 00 00 20-2011 MANUFACTURED VANITIES《已加工的浴室柜》.pdf_第4页
第4页 / 共6页
NAVY UFGS-12 36 00 00 20-2011 MANUFACTURED VANITIES《已加工的浴室柜》.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、*USACE / NAVFAC / AFCESA / NASA UFGS-12 36 00.00 20 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-12 36 00.00 20 (April 2006)UFGS-12301N (September 1999)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 12 - FURN

2、ISHINGSSECTION 12 36 00.00 20MANUFACTURED VANITIES08/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 VANITIES2.1.1 Quantity2.2 FINISHES2.2.1 Exposed Surfaces2.2.2 Concealed Surfaces2.3 END CURBS2.4 DRAWERSPART 3 EXECUTION3.1 INSTALLATION3.1.1 Final A

3、ssembly3.1.2 Fastening- End of Section Table of Contents -SECTION 12 36 00.00 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-12 36 00.00 20 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-12 36

4、00.00 20 (April 2006)UFGS-12301N (September 1999)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION 12 36 00.00 20MANUFACTURED VANITIES08/11*NOTE: This guide specification covers the requirements for vanities for Bachelor Enlisted Quarters (BEQ).Adhe

5、re to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose

6、applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Reques

7、t (CCR).*NOTE: Lavatories and wall base, if desired, must be specified in other sections. If the project requires custom wood millwork such as required in locations like the Marine Corps Air Station, Cherry Point and Marine Corps Base, Camp Lejeune, North Carolina, do not use this section. Custom wo

8、od vanities require the designer to show elevations, sections, and details which clarify materials, thicknesses, size, finishes, and support framing on the contract drawings and use Section 06 20 00 FINISH CARPENTRY to specify the product.*SECTION 12 36 00.00 20 Page 2Provided by IHSNot for ResaleNo

9、 reproduction or networking permitted without license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by o

10、rganization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.Ref

11、erences not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to w

12、ithin the text by the basic designation only.APA - THE ENGINEERED WOOD ASSOCIATION (APA)APA PS 1 (1995) Voluntary Product Standard for Construction and Industrial PlywoodU.S. GENERAL SERVICES ADMINISTRATION (GSA)CID A-A-50565 (Basic) Cabinet, Storage; Wardrobe, Three DrawerFED-STD-595 (Rev C) Colors

13、 Used in Government Procurement1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality contr

14、ol.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the sub

15、mittal is sufficiently important or complex in context of the project.SECTION 12 36 00.00 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-For submittals requiring Government approval on Army projects, a code of up to three characters within

16、the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ fo

17、r Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approva

18、l is required for submittals with a “G“ designation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following

19、 shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsVanities; GShow configuration, materials, thicknesses, hardware, finishes, and colors of vanities for the project.1.3 DELIVERY, STORAGE, AND HANDLINGDeliver vanities undamaged and store in a safe, dry, an

20、d clean location. Handle so as to prevent damage.PART 2 PRODUCTS2.1 VANITIES*NOTE: Insert type and size required. Sizes listed should be used unless otherwise approved by the Engineering Field Division Code 04 in writing. If other sizes are required, determine whether modification of door/intermedia

21、te panel configuration is required to maintain proper door size and structural support.*Provide, single lavatory type with double doors, Size (750 mm30 inches wide) (900 mm36 inches wide) (1050 mm42 inches wide) (1200 mm48 incheswide) double lavatory type with two sets of double doors, Size (1500 mm

22、60 inches wide) The type and size shall be as indicated _ mm inches wide, and except as specified herein. Wood construction shall be used. Particleboard shall not be used. Countertop, doors, and all wood panels shall be 20 mm 3/4 inch plywood, APA PS 1, Exterior Type, Grade SECTION 12 36 00.00 20 Pa

23、ge 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A. Chromium-plated brass pulls or aluminum pulls and chromium-plated, spring-loaded, self-closing, adjustable, European type hinges may be used in lieu of pulls, hinges, and magnetic catches.2.1.1

24、 Quantity_ As indicated.2.2 FINISHES*NOTE: Since a wood or steel constructed vanity is the Contractors option, specify finish, pattern, and color for laminated plastic for both and a paint color for steel.*Five-digit designations refer to FED-STD-595.2.2.1 Exposed SurfacesExterior of doors and expos

25、ed surfaces of cabinet body shall be decorative laminated plastic of color and pattern indicated specified.2.2.2 Concealed SurfacesInterior of doors and cabinet body, and concealed exterior surfaces of cabinet body, shall be nondecorative laminated plastic.2.3 END CURBS*NOTE: Delete this paragraph i

26、f end curbs are not required.*Provide end curbs to match back splash where end of countertop abuts a wall.2.4 DRAWERS*NOTE: Delete this paragraph if drawers are not required.*Where drawers are indicated in vanities, comply with CID A-A-50565 for drawers, drawer slides, and slide supports.PART 3 EXEC

27、UTION3.1 INSTALLATION3.1.1 Final AssemblyDistribute vanities to rooms as indicated as directed. Uncrate, assemble, adjust as necessary, and place as specified or indicated, complete with accessories and hardware. Position vanities as indicated as directed.SECTION 12 36 00.00 20 Page 5Provided by IHS

28、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.2 Fastening*NOTE: Ensure that work referred to is actually specified in the referenced sections.*Fasten wood vanities as indicated on the drawings and as specified. Fasten steel vanities through the holes in vanit

29、y back flanges. Fasteners shall be appropriate for use with the wall construction. Seal joint between back splash and wall and between end curb and wall as specified in Section 07 92 00 JOINT SEALANTS.- End of Section -SECTION 12 36 00.00 20 Page 6Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1