1、Lessons Learned Entry: 1428Lesson Info:a71 Lesson Number: 1428a71 Lesson Date: 2002-04-11a71 Submitting Organization: LARCa71 Submitted by: Grant WatsonSubject: Potential Hazard from Vent, Drain, and Relief Lines (2002) Abstract: A mishap has brought to light the importance of properly designed vent

2、 drain, and relief lines. Even though these lines are directly open to the atmosphere, the potential for over pressurization and rupture exists.Description of Driving Event: The mishap occurred when a tank located in a section of pipe used to drain water from a 4,300 psi air compressor ruptured. Th

3、e tank is isolated from the high-pressure air by a manual drain valve. A pipe that exits the bottom of the tank is directly open to the atmosphere. For the past 40 years, operators have been opening the drain valve to drain oil and moisture collectors without incident. On the day of the mishap, an o

4、perator drained the system as usual, but when the valve was closed, a very small amount of debris in the valve seat allowed high-pressure air to leak into the low-pressure drain collector tank.Lesson(s) Learned: At first glance, rupture of the tank appears to be one-fault tolerance - the drain line

5、would have to clog, and the valve would have to leak. But, the high-pressure air, which contained significant amounts of water, enabled on event to cause both conditions. The valve leaked in a manner that resulted in the Joule-Thompson effect. This caused the high-pressure air to be “throttled“ to a

6、 lower pressure and much lower temperature (on the order of -50 F). The lower temperature caused ice to eventually clog the exit of the tank and degrade the mechanical properties of the carbon steel tank material. With the exit clogged, the pressure inside the tank increased until the weakened tank

7、ruptured.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Recommendation(s): Facility safety personnel are encouraged to survey their facilities and look for vent, drain, and relief lines that may be susceptible to the above scenario. Even though they

8、 are open to the atmosphere, vent, drain, and relief lines should be designed for the maximum system pressure. Evidence of Recurrence Control Effectiveness: N/ADocuments Related to Lesson: N/AMission Directorate(s): a71 Exploration Systemsa71 Sciencea71 Space Operationsa71 Aeronautics ResearchAdditi

9、onal Key Phrase(s): a71 Accident Investigationa71 Facilitiesa71 Hardwarea71 Human Factorsa71 Mishap Reportinga71 Pressure Vesselsa71 Safety & Mission AssuranceAdditional Info: Approval Info: a71 Approval Date: 2004-06-04a71 Approval Name: Leslie Johnsona71 Approval Organization: LARCa71 Approval Phone Number: 757-864-9409Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASA S3 35-2010 American National Standard Method of Measurement of Performance Characteristics of Hearing Aids Under Simulated Real-Ear Working Conditions《模仿真耳工作条件下助听器性能特点的测量方法》.pdf ASA S3 35-2010 American National Standard Method of Measurement of Performance Characteristics of Hearing Aids Under Simulated Real-Ear Working Conditions《模仿真耳工作条件下助听器性能特点的测量方法》.pdf
  • ASA S3 36-2012 American National Standard Specification for a Manikin for Simulated in-situ Airborne Acoustic Measurements.pdf ASA S3 36-2012 American National Standard Specification for a Manikin for Simulated in-situ Airborne Acoustic Measurements.pdf
  • ASA S3 37-1987 American National Standard Preferred Earhook Nozzle Thread for Postauricular Hearing Aids《助听器首选钩状管口细丝》.pdf ASA S3 37-1987 American National Standard Preferred Earhook Nozzle Thread for Postauricular Hearing Aids《助听器首选钩状管口细丝》.pdf
  • ASA S3 39-1987 American National Standard Specifications for Instruments to Measure Aural Acoustic Impedance and Admittance (Aural Acoustic Immittance)《测量听觉声学阻抗和准入仪器规范(听觉声学导抗)》.pdf ASA S3 39-1987 American National Standard Specifications for Instruments to Measure Aural Acoustic Impedance and Admittance (Aural Acoustic Immittance)《测量听觉声学阻抗和准入仪器规范(听觉声学导抗)》.pdf
  • ASA S3 4-2007 AMERICAN NATIONAL STANDARD Procedure for the Computation of Loudness of Steady Sounds《IHS ASA订阅顾客稳定噪声计算程序及联系HIS Retail (1-800-854-7179)要求其它附件赠送本》.pdf ASA S3 4-2007 AMERICAN NATIONAL STANDARD Procedure for the Computation of Loudness of Steady Sounds《IHS ASA订阅顾客稳定噪声计算程序及联系HIS Retail (1-800-854-7179)要求其它附件赠送本》.pdf
  • ASA S3 41-2015 American National Standard Audible Emergency Evacuation Signal.pdf ASA S3 41-2015 American National Standard Audible Emergency Evacuation Signal.pdf
  • ASA S3 42 PART 2-2012 American National Standard Testing Hearing Aids C Part 2 Methods for characterizing signal processing in hearing aids with a speech-like signal (a nationally .pdf ASA S3 42 PART 2-2012 American National Standard Testing Hearing Aids C Part 2 Methods for characterizing signal processing in hearing aids with a speech-like signal (a nationally .pdf
  • ASA S3 42-1992 American National Standard Testing Hearing Aids with a Broad-Band Noise Signal《宽频带噪声信号测试助听器》.pdf ASA S3 42-1992 American National Standard Testing Hearing Aids with a Broad-Band Noise Signal《宽频带噪声信号测试助听器》.pdf
  • ASA S3 44 PART 1-2016 American National Standard Acoustics - Estimation of Noise  induced Hearing Loss-Part 1 Method for Calculating Expected Noise  induced Permanent Threshold Shi.pdf ASA S3 44 PART 1-2016 American National Standard Acoustics - Estimation of Noise induced Hearing Loss-Part 1 Method for Calculating Expected Noise induced Permanent Threshold Shi.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1