REG NASA-LLIS-2896-2010 Lessons Learned - GOX Vent Hood Failsafe Jackscrew.pdf

上传人:bowdiet140 文档编号:1019393 上传时间:2019-03-21 格式:PDF 页数:2 大小:20.02KB
下载 相关 举报
REG NASA-LLIS-2896-2010 Lessons Learned - GOX Vent Hood Failsafe Jackscrew.pdf_第1页
第1页 / 共2页
REG NASA-LLIS-2896-2010 Lessons Learned - GOX Vent Hood Failsafe Jackscrew.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Public Lessons Learned Entry: 2896 Lesson Info: Lesson Number: 2896 Lesson Date: 2010-05-21 Submitting Organization: KSC Submitted by: Annette Pitt Subject: GOX Vent Hood Failsafe Jackscrew Abstract: On the Space Shuttle launch tower, the swing arms that raise the gaseous oxygen (GOX) vent hood inco

2、rporate a jackscrew assembly. An addition to a commercial off-the-shelf (COTS) jackscrew assembly was designed and implemented. The failure of one of the jackscrews used to raise and lower the GOX vent hood was traced to wear of the drive nut threads. Close inspection of moving equipment should be p

3、erformed on a regular basis, regardless of the lack of published criteria. Description of Driving Event: The failure of one of the jackscrews used to raise and lower the gaseous oxygen (GOX) vent hood was traced to wear of the drive nut threads. This wear caused the threads to strip under use and al

4、lowed the hood to fall to its lowered position during raising operations. The cause of the wear was traced to the keyed shaft, coupled with a bend in the shaft itself that allowed the keyway to function as a lathe and remove a portion of the threads with each traverse of the shaft through the drive

5、nut. The wear of the drive nut or the straightness of the shaft were not checked regularly, and there were no instructions to do so. The use of a keyed shaft also added to the accelerated wear observed. Lesson(s) Learned: Close inspection of moving equipment should be performed on a regular basis re

6、gardless of the lack of published criteria. Recommendation(s): Keep abreast of community updates to the maintenance recommendations for similar items and incorporate changes to maintenance procedures as required. Watch for modifications that increase the safety and operability of equipment. Evidence

7、 of Recurrence Control Effectiveness: There have been no failures caused by wearout since implementing the increased maintenance. The secondary drive nut has never engaged. Documents Related to Lesson: GOX Vent Hood Jackscrew drawing document Click here to download communication document. Mission Di

8、rectorate(s): Exploration Systems Space Operations Additional Key Phrase(s): 1.Lifting Devices 1.Ground Equipment 1.Long term sustainability and maintenance planning 0.Entry Systems Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 1.Ground support sy

9、stems 1.Administration/Organization 1.Reliability 1.Maintenance 1.Logistics and maintenance 1.Launch support systems 1.Hardware 1.Ground Operations Additional Info: Project: Space Shuttle Program Approval Info: Approval Date: 2010-07-13 Approval Name: mbell Approval Organization: HQ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • CSN 35 8797 Cast 6 IEC 747-6 ZA A1+A2-1997 Semiconductor devices Discrete devices and integrated circuíts Part 6 Thyristors《半导体器件 分立器件和集成电路 第6部分:半导体闸流管》.pdf CSN 35 8797 Cast 6 IEC 747-6 ZA A1+A2-1997 Semiconductor devices Discrete devices and integrated circuíts Part 6 Thyristors《半导体器件 分立器件和集成电路 第6部分:半导体闸流管》.pdf
  • CSN 35 8797 Cast 8 IEC 747-8 ZA1+A2-1996 Semiconductor devices Discrete devices Part 8 Field-effect transistore《半导体设备 离散设备 第8部分:场效应晶体管》.pdf CSN 35 8797 Cast 8 IEC 747-8 ZA1+A2-1996 Semiconductor devices Discrete devices Part 8 Field-effect transistore《半导体设备 离散设备 第8部分:场效应晶体管》.pdf
  • CSN 35 9701-1993 Dielectric protective and working facilities for electrotechnics Operating rods fuse tongs and rescue hooks《电工的介质保护和工作设施 操纵杆;熔线管钳和救生钩》.pdf CSN 35 9701-1993 Dielectric protective and working facilities for electrotechnics Operating rods fuse tongs and rescue hooks《电工的介质保护和工作设施 操纵杆;熔线管钳和救生钩》.pdf
  • CSN 35 9703-1983 Discharge rod《放电棒》.pdf CSN 35 9703-1983 Discharge rod《放电棒》.pdf
  • CSN 35 9706-1993 Short - circuit sets for tramway and trolej-bus overhead contact line《有轨电车和无轨电车架空电车线的短路装置》.pdf CSN 35 9706-1993 Short - circuit sets for tramway and trolej-bus overhead contact line《有轨电车和无轨电车架空电车线的短路装置》.pdf
  • CSN 35 9750-1975 Locks closures and keys for electric distribution boards and substations《配电板和变电站的锁;封闭室和钥匙》.pdf CSN 35 9750-1975 Locks closures and keys for electric distribution boards and substations《配电板和变电站的锁;封闭室和钥匙》.pdf
  • CSN 35 9751-1975 Locks and keys for securing electric distribution equipment of transformer stations and UHV and HV substations《确保变电站及超高压和高压变电所配电设备安全的锁和钥匙》.pdf CSN 35 9751-1975 Locks and keys for securing electric distribution equipment of transformer stations and UHV and HV substations《确保变电站及超高压和高压变电所配电设备安全的锁和钥匙》.pdf
  • CSN 35 9752-1975 Locks and for securing electric equipment of HV LV transformer stations《高压 低压变压站电气设备安全锁和钥匙》.pdf CSN 35 9752-1975 Locks and for securing electric equipment of HV LV transformer stations《高压 低压变压站电气设备安全锁和钥匙》.pdf
  • CSN 35 9753-1975 Locks and keys for securing section circuit breakers of distribution equipment in power engineering sector《确保电力工程部门配电设备段断路器的锁和钥匙》.pdf CSN 35 9753-1975 Locks and keys for securing section circuit breakers of distribution equipment in power engineering sector《确保电力工程部门配电设备段断路器的锁和钥匙》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1