1、Public Lessons Learned Entry: 4618 Lesson Info: Lesson Number: 4618 Lesson Date: 2010-09-20 Submitting Organization: KSC Submitted by: Annette Pitt Subject: Cryogenic Line Sizing Abstract: A major problem in designing a cryogenic system in a spacecraft or launch vehicle is avoiding back-pressure bui

2、ldup, which will affect the ability to service and deservice the vehicle with cryogenic reactants. Servicing lines should be sized adequately for an existing baseline system; then the baseline tubing should be oversized to accommodate increased fluid flow rates that can result from new equipment or

3、changes in requirements. If these accommodations are not part of the initial design, servicing or venting paths may need to be added later. Description of Driving Event: Several years into the Shuttle Program, Extended Duration Operations (EDO) pallets were added in the Orbiter mid-body for some mis

4、sions. These pallets included up to four additional tanks of liquid hydrogen and liquid oxygen to support the onboard fuel cells, which generate power on orbit. This added capacity made it possible to run fuel cells for missions lasting up to 28 days. (The original Shuttle design was for a maximum o

5、f 14 days on orbit.) On several occasions (and in all instances of pallet loading), full loading of the pallet was not achieved. The consensus at the time was that the vent tubing for the EDO pallets and Tank 3 was not sized to accommodate the increased flow from additional tanks during loading. The

6、 EDO pallets were not part of the original Shuttle design. Therefore, original fill and vent tubes were not sized to accommodate the added requirements. However, if the lines had been sized with excess capacity, this modification might have been better supported. Lesson(s) Learned: Oversizing cryoge

7、nic (or other) commodity lines in a spacecraft to accommodate higher flow rates is an advantage, but the future need for more capacity must be likely in order to justify the additional cost and weight. Recommendation(s): During initial design, engineers should consider the cost and weight of oversiz

8、ing servicing and vent lines against the likelihood of increased flow rate requirements. Evidence of Recurrence Control Effectiveness: N/A Documents Related to Lesson: N/A Mission Directorate(s): Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Explor

9、ation Systems Space Operations Aeronautics Research Additional Key Phrase(s): 1.Systems analysis - cost analysis 1.Mission and systems trade studies 1.Long term sustainability and maintenance planning 1.Level II/III requirements definition 1.Engineering design and project processes and standards 0.C

10、rew operations and support concepts 1.Pressure Vessels 1.Spacecraft 0.Acquisition / procurement strategy and planning 1.Orbiting Vehicles 1.Cryogenic Systems 1.Launch Vehicle 0.Crew Operations Additional Info: Project: Space Shuttle Program Approval Info: Approval Date: 2011-09-28 Approval Name: mbell Approval Organization: HQ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASHRAE 4702-2004 A Preliminary Investigation on the Use of Ultra-Wideband Radar for Moisture Detection in Building Envelopes《建筑围护结构 对使用超宽带雷达水分检测的初步调查》.pdf ASHRAE 4702-2004 A Preliminary Investigation on the Use of Ultra-Wideband Radar for Moisture Detection in Building Envelopes《建筑围护结构 对使用超宽带雷达水分检测的初步调查》.pdf
  • ASHRAE 4703-2004 A Study on the Control Methods for Radiant Floor Heating and Cooling System in Residential Building《一份研究报告 在住宅建筑中地板辐射采暖和制冷系统的控制方法》.pdf ASHRAE 4703-2004 A Study on the Control Methods for Radiant Floor Heating and Cooling System in Residential Building《一份研究报告 在住宅建筑中地板辐射采暖和制冷系统的控制方法》.pdf
  • ASHRAE 4704-2004 Analysis and Validation of a Psychrometric Apparatus《分析和验证某状态器具》.pdf ASHRAE 4704-2004 Analysis and Validation of a Psychrometric Apparatus《分析和验证某状态器具》.pdf
  • ASHRAE 4705-2004 Axial-Flow Air-Vapor Compression Rdfrigerating System for Air Conditioning Cooled by Ciculating Water《循环水冷却空调 轴流式空气-蒸汽压缩Rd制冷系统》.pdf ASHRAE 4705-2004 Axial-Flow Air-Vapor Compression Rdfrigerating System for Air Conditioning Cooled by Ciculating Water《循环水冷却空调 轴流式空气-蒸汽压缩Rd制冷系统》.pdf
  • ASHRAE 4706-2004 Benefits of Multi-Building Electric Load Aggregation Actural and Simulation Case Studies《多建筑电气负荷聚集优点 实际与模拟个案研究RP-1146》.pdf ASHRAE 4706-2004 Benefits of Multi-Building Electric Load Aggregation Actural and Simulation Case Studies《多建筑电气负荷聚集优点 实际与模拟个案研究RP-1146》.pdf
  • ASHRAE 4707-2004 Calculation of Food Freezing Times and Heat Transfer Coefficients《计算食品冻结时间和传热系数 RP-1123》.pdf ASHRAE 4707-2004 Calculation of Food Freezing Times and Heat Transfer Coefficients《计算食品冻结时间和传热系数 RP-1123》.pdf
  • ASHRAE 4708-2004 Calibration and Testing of Thermal Simulation Models of Air Heaters《热模拟模型的空气加热器的校准和测试》.pdf ASHRAE 4708-2004 Calibration and Testing of Thermal Simulation Models of Air Heaters《热模拟模型的空气加热器的校准和测试》.pdf
  • ASHRAE 4709-2004 CFD-Based Parametric Study of Ventilation and Diesel Exhaust in Locomotive Facilities《机车设施RP-1191的通风及柴油机排气 基于CFD参数研究》.pdf ASHRAE 4709-2004 CFD-Based Parametric Study of Ventilation and Diesel Exhaust in Locomotive Facilities《机车设施RP-1191的通风及柴油机排气 基于CFD参数研究》.pdf
  • ASHRAE 4710-2004 Climatic Impacts on Heating Seasonal Performance Factor (HSPF) and Seasonal Energy Efficiency Ratio (SEER) for Air-Source Heat Pumps《气候对空气源热泵的供暖季节性能系数(HSPF)和季节能效比(.pdf ASHRAE 4710-2004 Climatic Impacts on Heating Seasonal Performance Factor (HSPF) and Seasonal Energy Efficiency Ratio (SEER) for Air-Source Heat Pumps《气候对空气源热泵的供暖季节性能系数(HSPF)和季节能效比(.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1