UL 1088 CRD-2018 UL Standard for Safety Temporary Lighting Strings - Section Paragraph Reference 18 1 4 Subject Metallic Lamp Guards that are Unlikely to Become Energized (Edition.pdf

上传人:sofeeling205 文档编号:1067320 上传时间:2019-04-02 格式:PDF 页数:2 大小:29.90KB
下载 相关 举报
UL 1088 CRD-2018 UL Standard for Safety Temporary Lighting Strings - Section  Paragraph Reference 18 1 4 Subject Metallic Lamp Guards that are Unlikely to Become Energized (Edition.pdf_第1页
第1页 / 共2页
UL 1088 CRD-2018 UL Standard for Safety Temporary Lighting Strings - Section  Paragraph Reference 18 1 4 Subject Metallic Lamp Guards that are Unlikely to Become Energized (Edition.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): XBRT, XBRT7Standard Number: UL 1088Standard Title: Standard for Temporary Lighting StringsEdition Date: July 10, 2015Edition Number: 7Section / Paragraph Reference: 18.1.4Subject: Metallic Lamp Guards

3、 that are Unlikely to Become EnergizedDECISION:18.1.4 A metal lamp guard with or without a nonmetallic coating shall be positively bonded to theequipment grounding conductor of the string.Exception No. 1: A metal lamp guard that is shipped separate from the lampholder shall be provided withinstructi

4、ons (see 44.17) for positive connection to the equipment grounding conductor of the string unlessthe bonding connection is automatically obtained.Exception No. 2: A metal lamp guard that must be removed for relamping shall be designed so that thebonding connection is automatically provided on assemb

5、ly to the lampholder.Exception No. 3: A metal lamp guard of a temporary lighting string employing non-replaceable lightsources that is unlikely to become energized.RATIONALE FOR DECISION:Prior to the 6th Edition, UL 1088 only covered temporary lighting strings employing Edison screw baselampholders.

6、 As a result the requirements were broadly written to mitigate inherent risks of electric shockassociated with the use of replaceable lamps in a construction site environment. Now the scope of UL1088 also covers temporary lighting strings employing non-replaceable LED light sources. This allowssome

7、of the specific risk of shock conditions originally anticipated by the standard to be eliminated ormitigated by product design. While this CRD does not modify the existing requirements applicable totraditional lighting strings employing lamps with Edison screw bases, it provides an alternative appro

8、achfor grounding requirements in new temporary lighting strings with non-replaceable LED light sources.The potential risk of electric shock is addressed in ANSI/UL 1088 / CAN/ULC-S1088 by multiple layers ofconstruction requirements including minimum spacings, adequacy of insulation, grounding and bo

9、nding,as well as testing requirements including abnormal operation, dielectric voltage withstand and continuitytests.However, regardless of construction design Clause 18.1.4 of the standard requires all temporary lightingstrings provided with metal guards to have the guard bonded to the equipment gr

10、ounding conductor(EGC). This is to further mitigate the potential risk of electric shock even during relamping when the guardcould inadvertently become energized from an exposed screwshell. The standard did not anticipate newconstructions of temporary lighting strings with non-replaceable LEDs where

11、 a metallic lamp guard maybe provided as a decorative feature only.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULThe Canadian standards for portable luminaires CSA C22.2 No. 250.4, which also covers temporarylighting strings, and the US stan

12、dard for portable luminaires ANSI/UL 153 both have provisions to allowaccessible non-current carrying parts that are suitably insulated and not likely to become energized to beprovided without being bonded to the EGC.An equivalent provision is needed in ANSI/UL 1088 / CAN/ULC-S1088 to accommodate ex

13、posed metalparts of temporary lighting strings that are unlikely to contact live parts under any condition of use,including during installation and servicing.This proposal is intended to accommodate such temporary lighting string designs while maintaining thesame level of safety anticipated for meta

14、l guards of temporary lighting strings employing Edison screwbase lampholders.The revision to 4.2.5.2.3 corrects a discrepancy between the stated minimum distance of 365.8 mm thatmust exist between convenience receptacles and the equivalent value of 12 ft. shown in parenthesis. Therequirement was in

15、troduced in the 15th Edition of UL 48 to align with section 210.52(A)(1) of the NEC thatpermits up to 12 feet of space horizontally between receptacles along a floor line (i.e. 6 ft. in eitherdirection from a center point). However the stated value of 365.8 mm does not convert to 12 ft. Addingthe co

16、rrect metric value of 3.66 m will correct this discrepancy.The revisions to 4.3.5.1.3 and 4.3.5.2.2 will fix the cross-reference paragraph numbers to point the correctmarkings for dedicated and convenience receptacles in section 7 of the standard.Copyright 2018 UL LLCUL LLC, in performing its functi

17、ons in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the opinion of UL LLC. in practically applying therequirements of the s

18、tandard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Decisions by anyone. UL LLC shall not incur anyobligation or liability

19、 for damages, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 1088 -2-

展开阅读全文
相关资源
猜你喜欢
  • NF T57-211-1994 Plastics piping sytems Glass-reinforced thermosetting plastics (grp) pipes and fittings Methods for regression analysis and their use 《塑料管道系统 玻璃纤维增强式热固性塑料管件和配件 回归分析.pdf NF T57-211-1994 Plastics piping sytems Glass-reinforced thermosetting plastics (grp) pipes and fittings Methods for regression analysis and their use 《塑料管道系统 玻璃纤维增强式热固性塑料管件和配件 回归分析.pdf
  • NF T57-212-1994 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination of the creep factor dry conditions 《塑料管道系统 玻璃纤维增强式热固性管件 蠕变系数干燥条件的测定》.pdf NF T57-212-1994 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination of the creep factor dry conditions 《塑料管道系统 玻璃纤维增强式热固性管件 蠕变系数干燥条件的测定》.pdf
  • NF T57-216-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes and fittings Determination of the resistance to chemical attack from the inside of a sec.pdf NF T57-216-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes and fittings Determination of the resistance to chemical attack from the inside of a sec.pdf
  • NF T57-218-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Test method to prove the resistance to initial ring deflection 《塑料管道系统 玻璃纤维增强式热固塑料管件 检验初.pdf NF T57-218-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Test method to prove the resistance to initial ring deflection 《塑料管道系统 玻璃纤维增强式热固塑料管件 检验初.pdf
  • NF T57-220-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination of initial specific ring stiffness 《塑料管道系统 玻璃纤维增强式热固性塑料管件 初始特定劲度的测定》.pdf NF T57-220-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination of initial specific ring stiffness 《塑料管道系统 玻璃纤维增强式热固性塑料管件 初始特定劲度的测定》.pdf
  • NF T57-221-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes and fittings Test methods to prove the leaktightness of the wall under short-term intern.pdf NF T57-221-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes and fittings Test methods to prove the leaktightness of the wall under short-term intern.pdf
  • NF T57-222-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination of initial longitudinal tensile properties 《塑料管道系统 玻璃纤维增强式热固塑料管件 初始纵向拉伸性能的.pdf NF T57-222-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination of initial longitudinal tensile properties 《塑料管道系统 玻璃纤维增强式热固塑料管件 初始纵向拉伸性能的.pdf
  • NF T57-223-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination O the apparent initial circumferential tensile strength 《塑料管道系统 玻璃增强式热固性塑料.pdf NF T57-223-1996 Plastics piping systems Glass-reinforced thermosetting plastics (grp) pipes Determination O the apparent initial circumferential tensile strength 《塑料管道系统 玻璃增强式热固性塑料.pdf
  • NF T57-227-1997 Plastics piping systems Glass-reinforced thermosetting plastics (GRP) pipes Test method for the effects of cyclic internal pressure 《塑料管道系统 玻璃纤维增强式热固性塑料管件 周期性内压效应的试.pdf NF T57-227-1997 Plastics piping systems Glass-reinforced thermosetting plastics (GRP) pipes Test method for the effects of cyclic internal pressure 《塑料管道系统 玻璃纤维增强式热固性塑料管件 周期性内压效应的试.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1