UL 2395-2002 UL Standard for Safety Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials《加热和冷却设备上固定热绝缘材料用胶粘剂》.pdf

上传人:proposalcash356 文档编号:1067916 上传时间:2019-04-02 格式:PDF 页数:16 大小:37.63KB
下载 相关 举报
UL 2395-2002 UL Standard for Safety Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials《加热和冷却设备上固定热绝缘材料用胶粘剂》.pdf_第1页
第1页 / 共16页
UL 2395-2002 UL Standard for Safety Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials《加热和冷却设备上固定热绝缘材料用胶粘剂》.pdf_第2页
第2页 / 共16页
UL 2395-2002 UL Standard for Safety Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials《加热和冷却设备上固定热绝缘材料用胶粘剂》.pdf_第3页
第3页 / 共16页
UL 2395-2002 UL Standard for Safety Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials《加热和冷却设备上固定热绝缘材料用胶粘剂》.pdf_第4页
第4页 / 共16页
UL 2395-2002 UL Standard for Safety Adhesives for Use in Heating and Cooling Appliances to Secure Thermal Insulation Materials《加热和冷却设备上固定热绝缘材料用胶粘剂》.pdf_第5页
第5页 / 共16页
点击查看更多>>
资源描述

1、UL 2395ISBN 0-7629-0837-8Adhesives for Use in Heatingand Cooling Appliances toSecure Thermal InsulationMaterialsUnderwriters Laboratories Inc. (UL)333 Pfingsten RoadNorthbrook, IL 60062-2096UL Standard for Safety for Adhesives for Use in Heating and Cooling Appliances to Secure ThermalInsulation Mat

2、erials, UL 2395First Edition, Dated December 27, 2002SUMMARY OF TOPICSThis is the first edition of the Standard for Adhesives for Use in Heating and Cooling Appliancesto Secure Thermal Insulation Materials, UL 2395.The new requirements are substantially in accordance with ULs Bulletin(s) on this sub

3、ject dated May 30,2002. The bulletin(s) is now obsolete and may be discarded.The master for this Standard at ULs Northbrook Office is the official document insofar as it relates to aUL service and the compliance of a product with respect to the requirements for that product and service,or if there a

4、re questions regarding the accuracy of this Standard.ULs Standards for Safety are copyrighted by UL. Neither a printed copy of a Standard, nor the distributiondiskette for a Standard-on-Diskette and the file for the Standard on the distribution diskette should bealtered in any way. All of ULs Standa

5、rds and all copyrights, ownerships, and rights regarding thoseStandards shall remain the sole and exclusive property of UL.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, re

6、cording, or otherwisewithout prior permission of UL.Revisions of UL Standards for Safety are issued from time to time. A UL Standard for Safety is currentonly if it incorporates the most recently adopted revisions.UL provides this Standard as is without warranty of any kind, either expressed or impl

7、ied, including butnot limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the

8、use of or theinability to use this Standard, even if UL or an authorized UL representative has been advised of thepossibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid forthis Standard, regardless of the form of the claim.UL will attempt to answer supp

9、ort requests concerning electronic versions of its Standards. However, thissupport service is offered on a reasonable efforts basis only, and UL may not be able to resolve everysupport request. UL supports the electronic versions of its Standards only if they are used under theconditions and operati

10、ng systems for which it is intended. ULs support policies may change fromtime-to-time without notification.UL reserves the right to change the format, presentation, file types and formats, delivery methods andformats, and the like of both its printed and electronic Standards without prior notice.DEC

11、EMBER 27, 2002 UL 2395 tr1Purchasers of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and holdUL harmless from and against any loss, expense, liability, damage, claim, or judgement (includingreasonable attorneys fees) resulting from any error or deviation introduced

12、 while purchaser is storing anelectronic Standard on the purchasers computer system.If a single-user version electronic Standard was purchased, one copy of this Standard may be stored onthe hard disk of a single personal computer, or on a single LAN file-server or the permanent storagedevice of a mu

13、ltiple-user computer in such a manner that this Standard may only be accessed by one userat a time and for which there is no possibility of multiple concurrent access.If a multiple-user version electronic Standard was purchased, one copy of the Standard may be stored ona single LAN file-server, or o

14、n the permanent storage device of a multiple-user computer, or on an Intranetserver. The number of concurrent users shall not exceed the number of users authorized.Electronic Standards are intended for on-line use, such as for viewing the requirements of a Standard,conducting a word search, and the

15、like. Only one copy of the Standard may be printed from eachsingle-user version of an electronic Standard. Only one copy of the Standard may be printed for eachauthorized user of a multiple-user version of an electronic Standard. Because of differences in thecomputer/software/printer setup used by U

16、L and those of electronic Standards purchasers, the printedcopy obtained by a purchaser may not look exactly like the on-line screen view or the printed Standard.An employee of an organization purchasing a UL Standard can make a copy of the page or pages beingviewed for their own fair and/or practic

17、al internal use.The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, figures,and/or other elements of the Standard having future effective dates as indicated in the note following theaffected item. The prior text for requirements that have been revised

18、and that have a future effective dateare located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice.New product submittals made prior to a specified future effective date will be judged under all of therequirements in this Standard including those requirements with a specified

19、future effective date, unlessthe applicant specifically requests that the product be judged under the current requirements. However, ifthe applicant elects this option, it should be noted that compliance with all the requirements in thisStandard will be required as a condition of continued Classific

20、ation and Follow-Up Services after theeffective date, and understanding of this should be signified in writing.Copyright 2002 Underwriters Laboratories Inc.This Standard consists of pages dated as shown in the following checklist:Page Date1-12 .December 27, 2002DECEMBER 27, 2002 UL 2395tr2December 2

21、7, 20021UL 2395Standard for Adhesives for Use in Heating and Cooling Appliances toSecure Thermal InsulationFirst EditionDecember 27, 2002An effective date included as a note immediately following certain requirementsis one established by Underwriters Laboratories Inc.Revisions of this Standard will

22、be made by issuing revised or additional pagesbearing their date of issue. A UL Standard is current only if it incorporates themost recently adopted revisions, all of which are itemized on the transmittal noticethat accompanies the latest set of revised requirements.ISBN 0-7629-0837-8COPYRIGHT 2002

23、UNDERWRITERS LABORATORIES INC.DECEMBER 27, 2002UL 23952No Text on This PageCONTENTSFOREWORD 4INTRODUCTION1 Scope .52 Glossary .53 Units of Measurement .54 Undated References 5PERFORMANCE5 General 56 Sample Requirements for Peel Test .67 Conditioning Requirements for Peel Test 68 Peel Test 79 Identif

24、ication Tests 79.1 General .79.2 Method for determination of ash content in solid samples .89.3 Method for determination of ash content in liquid samples .89.4 Method for determination of solid content .109.5 Determination of weight per gallon .119.6 Qualitative infrared analysis .1110 Sample Requir

25、ements for Flame Spread and Smoke Developed Test .1111 Flame Spread and Smoke Developed Test 12MARKING12 General 12DECEMBER 27, 2002 UL 2395 3FOREWORDA. This Standard contains basic requirements for products covered by Underwriters Laboratories Inc. (UL)under its Follow-Up Service for this category

26、within the limitations given below and in the Scope sectionof this Standard. These requirements are based upon sound engineering principles, research, records oftests and field experience, and an appreciation of the problems of manufacture, installation, and usederived from consultation with and inf

27、ormation obtained from manufacturers, users, inspection authorities,and others having specialized experience. They are subject to revision as further experience andinvestigation may show is necessary or desirable.B. The observance of the requirements of this Standard by a manufacturer is one of the

28、conditions of thecontinued coverage of the manufacturers product.C. A product which complies with the text of this Standard will not necessarily be judged to comply withthe Standard if, when examined and tested, it is found to have other features which impair the level ofsafety contemplated by these

29、 requirements.D. A product that contains features, characteristics, components, materials, or systems new or differentfrom those covered by the requirements in this standard, and that involves a risk of fire or of electric shockor injury to persons shall be evaluated using appropriate additional com

30、ponent and end-productrequirements to maintain the level of safety as originally anticipated by the intent of this standard. Aproduct whose features, characteristics, components, materials, or systems conflict with specificrequirements or provisions of this standard does not comply with this standar

31、d. Revision of requirementsshall be proposed and adopted in conformance with the methods employed for development, revision, andimplementation of this standard.E. UL, in performing its functions in accordance with its objectives, does not assume or undertake todischarge any responsibility of the man

32、ufacturer or any other party. The opinions and findings of ULrepresent its professional judgment given with due consideration to the necessary limitations of practicaloperation and state of the art at the time the Standard is processed. UL shall not be responsible to anyonefor the use of or reliance

33、 upon this Standard by anyone. UL shall not incur any obligation or liability fordamages, including consequential damages, arising out of or in connection with the use, interpretation of,or reliance upon this Standard.F. Many tests required by the Standards of UL are inherently hazardous and adequat

34、e safeguards forpersonnel and property shall be employed in conducting such tests.DECEMBER 27, 2002UL 23954INTRODUCTION1 Scope1.1 These requirements describe the test methods used to determine the adhesion qualities of, and therisk of fire associated with, adhesives used in heating and cooling appli

35、ances to secure insulation.1.2 Requirements for insulation adhesive testing procedures are included in the Standard for Test forSurface Burning Characteristics of Building Materials, UL 723. Requirements for insulation adhesivesample preparation are included in the Test Method for Peel or Stripping

36、Strength of Adhesive Bonds,ASTM D903.2 Glossary2.1 For the purpose of this standard, the following definitions apply.2.2 ADHESIVE A substance used to bond two or more solids so that they act or can be used as asingle piece; examples are: resins, formaldehydes, glue, paste, cement, putty, and polyvin

37、yl resinemulsions.2.3 INSULATION Material used in walls, ceilings, and floors to retard the passage of heat and sound.3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated r

38、eference to a code or standard appearing in the requirements of this standard shall beinterpreted as referring to the latest edition of that code or standard.PERFORMANCE5 General5.1 Adhesives used in heating and cooling appliances to secure insulation shall comply with theapplicable test requirement

39、s in Sections611.DECEMBER 27, 2002 UL 2395 56 Sample Requirements for Peel Test6.1 Each sample is to be prepared in accordance with 6.2 6.4. The specimens supplied for testing areto be representative samples of the various thermal insulation materials and metallic substrates.6.2 Each test specimen s

40、hall be as described in the Test Method for Peel or Stripping Strength ofAdhesive Bonds, ASTM D903.6.3 Each test specimen is to be of one piece of thermal insulation having a 16 kg/m3 24 kg/m3(1 1-1/2pound/feet3) density and a thickness of 25 mm (1 inch), measuring 25 mm (1 inch) by 305 mm (12 inche

41、s).Forty test specimens shall be prepared for each substrate in 6.4 (a) (d).6.4 Each specimen shall be bonded at the adhesive manufacturers maximum recommended coveragerate (minimum thickness) for 152 mm (6 inches) at one end, to a 25 mm (1 inch) by 203 mm (8 inch) byno less than 0.79 mm (1/32 inch)

42、 piece of each of the following:a) Steel painted with acrylic paint;b) Steel painted with alkyd paint;c) Cold-rolled steel; andd) Galvanized steel.7 Conditioning Requirements for Peel Test7.1 Five test samples from each metallic substrate in Section 6, Sample Requirements for Peel Test, areto be sub

43、jected to tests described in Section 8, Peel Test, without undergoing conditioning.7.2 Five test samples from each metallic substrate described in Section 6 are to be conditioned asspecified in 7.4 7.8.7.3 Two separate batches of five samples are required where concurrent conditioning durations of 3

44、0 and60 days are specified.7.4 The samples are to undergo a 24 hour low temperature conditioning at -20F (-29C).7.5 The samples are to undergo a 30 and 60 day conditioning period at an elevated temperature of 50C(90F) above the maximum normal use temperature, as specified by the manufacturer, of the

45、 adhesives.7.6 The samples are to undergo a 30 and 60 day conditioning period at 140F (60C) and 97 3 percentrelative humidity.7.7 The samples are to undergo a 7 hour conditioning period at the maximum abnormal temperature, asspecified by the manufacturer, of the adhesive.DECEMBER 27, 2002UL 239567.8

46、 The samples are to be cycled 5 times in accordance with the following:a) 24 hours at the maximum operating temperature, as designated by the manufacturer, of theadhesive;b) 1 hour at 73F (23C) and 50 percent relative humidity; andc) 24 hours at 140F (60C) and 97 3 percent relative humidity.8 Peel T

47、est8.1 Each metallic substrate is to be held stationary while the unbonded end of the thermal insulationspecimen is slowly pulled at an angle of 180 degrees to the metal strip.8.2 After peeling the thermal insulation from the metal strip, each specimen is to be examined todetermine if separation of

48、the adhesive bond and thermal insulation occurs.8.3 The strength of the adhesive bond shall be stronger than the physical or mechanical strength of theinsulation for each specimen.9 Identification Tests9.1 General9.1.1 Identification tests are to include the following:a) Method of determination of a

49、sh content in solid samples, 9.2, or Method for determination ofash content in liquid samples, 9.3;b) Method for determination of solid content, 9.4;c) Determination of weight per gallon, 9.5, and;d) The qualitative infrared analysis, 9.6.9.1.2 A portion of a pint sample of the adhesive is to be used for each of the identification tests in 9.2 9.6.9.1.3 A Material Safety Data Sheet (MSDS) is to be provided with the adhesive.DECEMBER 27, 2002 UL 2395 79.2 Method for determination of ash content in solid samples9.2.1 The method for determination