UL 393-2005 UL Standard for Safety Indicating Pressure Gauges for Fire-Protection Service (Eighth Edition Reprint with Revisions through and Including March 31 2009)《消防设备用压力指示计》.pdf

上传人:刘芸 文档编号:1068111 上传时间:2019-04-02 格式:PDF 页数:22 大小:193.06KB
下载 相关 举报
UL 393-2005 UL Standard for Safety Indicating Pressure Gauges for Fire-Protection Service (Eighth Edition Reprint with Revisions through and Including March 31 2009)《消防设备用压力指示计》.pdf_第1页
第1页 / 共22页
UL 393-2005 UL Standard for Safety Indicating Pressure Gauges for Fire-Protection Service (Eighth Edition Reprint with Revisions through and Including March 31 2009)《消防设备用压力指示计》.pdf_第2页
第2页 / 共22页
UL 393-2005 UL Standard for Safety Indicating Pressure Gauges for Fire-Protection Service (Eighth Edition Reprint with Revisions through and Including March 31 2009)《消防设备用压力指示计》.pdf_第3页
第3页 / 共22页
UL 393-2005 UL Standard for Safety Indicating Pressure Gauges for Fire-Protection Service (Eighth Edition Reprint with Revisions through and Including March 31 2009)《消防设备用压力指示计》.pdf_第4页
第4页 / 共22页
UL 393-2005 UL Standard for Safety Indicating Pressure Gauges for Fire-Protection Service (Eighth Edition Reprint with Revisions through and Including March 31 2009)《消防设备用压力指示计》.pdf_第5页
第5页 / 共22页
点击查看更多>>
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL 393Indicating Pressure Gauges forFire-Protection ServiceUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT

2、HORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUnderwriters Laboratories Inc. (UL)333 Pfingsten RoadNorthbrook, IL 60062-2096UL Standard for Safety for Indicating Pressure Gauges for Fire-Protection Service, UL 393Eighth Edition, Dated March 17, 2005Revisions: This Standar

3、d contains revisions through and including March 31, 2009.SUMMARY OF TOPICSThe following changes in requirements to the Standard for Indicating Pressure Gauges forFire-Protection Service, UL 393, are included in these revisions:1. Additional dial pressure range for Table 7.1Text that has been change

4、d in any manner is marked with a vertical line in the margin. Changes inrequirements are marked with a vertical line in the margin and are followed by an effective date noteindicating the date of publication or the date on which the changed requirement becomes effective.The new and revised requireme

5、nts are substantially in accordance with ULs Proposal(s) on this subjectdated February 13, 2009.The revisions dated March 31, 2009 include a reprinted title page (page1) for this Standard.The UL Foreword is no longer located within the UL Standard. For information concerning the use andapplication o

6、f the requirements contained in this Standard, the current version of the UL Foreword islocated on ULStandardsInfoNet at: http:/ master for this Standard at ULs Northbrook Office is the official document insofar as it relates to aUL service and the compliance of a product with respect to the require

7、ments for that product and service,or if there are questions regarding the accuracy of this Standard.ULs Standards for Safety are copyrighted by UL. Neither a printed copy of a Standard, nor the distributiondiskette for a Standard-on-Diskette and the file for the Standard on the distribution diskett

8、e should bealtered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding thoseStandards shall remain the sole and exclusive property of UL.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by an

9、y means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.Revisions of UL Standards for Safety are issued from time to time. A UL Standard for Safety is currentonly if it incorporates the most recently adopted revisions.UL provides this Standard as is withou

10、t warranty of any kind, either expressed or implied, including butnot limited to, the implied warranties of merchantability or fitness for any purpose.MARCH 31, 2009 UL 393 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULIn no event will UL

11、 be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this Standard, even if UL or an authorized UL representative has been advised of thepossibil

12、ity of such damage. In no event shall ULs liability for any damage ever exceed the price paid forthis Standard, regardless of the form of the claim.UL will attempt to answer support requests concerning electronic versions of its Standards. However, thissupport service is offered on a reasonable effo

13、rts basis only, and UL may not be able to resolve everysupport request. UL supports the electronic versions of its Standards only if they are used under theconditions and operating systems for which it is intended. ULs support policies may change fromtime-to-time without notification.UL reserves the

14、 right to change the format, presentation, file types and formats, delivery methods andformats, and the like of both its printed and electronic Standards without prior notice.Purchasers of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and holdUL harmless from and ag

15、ainst any loss, expense, liability, damage, claim, or judgement (includingreasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing anelectronic Standard on the purchasers computer system.If a single-user version electronic Standard was purchased, one cop

16、y of this Standard may be stored onthe hard disk of a single personal computer, or on a single LAN file-server or the permanent storagedevice of a multiple-user computer in such a manner that this Standard may only be accessed by one userat a time and for which there is no possibility of multiple co

17、ncurrent access.If a multiple-user version electronic Standard was purchased, one copy of the Standard may be stored ona single LAN file-server, or on the permanent storage device of a multiple-user computer, or on an Intranetserver. The number of concurrent users shall not exceed the number of user

18、s authorized.Electronic Standards are intended for on-line use, such as for viewing the requirements of a Standard,conducting a word search, and the like. Only one copy of the Standard may be printed from eachsingle-user version of an electronic Standard. Only one copy of the Standard may be printed

19、 for eachauthorized user of a multiple-user version of an electronic Standard. Because of differences in thecomputer/software/printer setup used by UL and those of electronic Standards purchasers, the printedcopy obtained by a purchaser may not look exactly like the on-line screen view or the printe

20、d Standard.An employee of an organization purchasing a UL Standard can make a copy of the page or pages beingviewed for their own fair and/or practical internal use.The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, figures,and/or other elements of th

21、e Standard having future effective dates as indicated in the note following theaffected item. The prior text for requirements that have been revised and that have a future effective dateare located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice.New product submittals made p

22、rior to a specified future effective date will be judged under all of therequirements in this Standard including those requirements with a specified future effective date, unlessthe applicant specifically requests that the product be judged under the current requirements. However, ifthe applicant el

23、ects this option, it should be noted that compliance with all the requirements in thisStandard will be required as a condition of continued Listing, Recognized, and Follow-Up Services afterthe effective date, and understanding of this should be signified in writing.Copyright 2009 Underwriters Labora

24、tories Inc.MARCH 31, 2009 UL 393tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULThis Standard consists of pages dated as shown in the following checklist:Page Date1March 31, 20092-5March 17, 20056-6B.March 31, 20097-14 .March 17, 2005MARCH

25、31, 2009 UL 393 tr3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMARCH 31, 2009 UL 393tr4No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMARCH 17, 2005(Title Page R

26、eprinted: March 31, 2009)1UL 393Standard for Indicating Pressure Gauges for Fire-Protection ServiceFirst Edition October, 1921Second Edition March, 1967Third Edition March, 1973Fourth Edition June, 1979Fifth Edition July, 1985Sixth Edition January, 1991Seventh Edition June, 1996Eighth EditionMarch 1

27、7, 2005Comments or proposals for revisions on any part of the Standard may besubmitted to UL at any time. Proposals should be submitted via a ProposalRequest in ULs On-Line Collaborative Standards Development System (CSDS)at http:/.ULs Standards for Safety are copyrighted by UL. Neither a printed no

28、r electroniccopy of a Standard should be altered in any way. All of ULs Standards and allcopyrights, ownerships, and rights regarding those Standards shall remain thesole and exclusive property of UL.COPYRIGHT 2009 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPR

29、ODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMARCH 17, 2005INDICATING PRESSURE GAUGES FOR FIRE-PROTECTION SERVICE - UL 3932No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Components 43 U

30、nits of Measurement .54 Undated References 5CONSTRUCTION5 General 56 Sizes 57 Dials 58 Pointers 79 Windows .710 Elastic Elements .711 Materials 812 Pointers 8PERFORMANCE13 General .814 Nonmetallic Components .814.1 General 814.2 Light and water test 914.3 Air-oven aging test 914.4 Low temperature ex

31、posure 1015 Accuracy Test 1016 Operation Test .1117 Vibration Test 1118 Excess Pressure Test .1219 Hydrostatic Strength Test 1220 Falling Ball Impact Test 1221 Window Impact Strength Test 13MARKING22 General 13MARCH 17, 2005 INDICATING PRESSURE GAUGES FOR FIRE-PROTECTION SERVICE - UL 393 3UL COPYRIG

32、HTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover indicating pressure gauges of the elastic element type intended for usewith sprinkler or standpipe equipment for fire-protection service.1.2 These requiremen

33、ts cover gauges of trade sizes 3-1/2 to 4-1/2 inches (90 to 115 mm), inclusive.1.3 The gauges covered by these requirements are intended for installation and use according to thefollowing Standards of the National Fire Protection Association:a) Standard for Installation of Sprinkler Systems, NFPA 13

34、;b) Standard for Installation of Standpipe and Hose Systems, NFPA 14;c) Standard for Installation of Private Fire Service Mains and Their Appurtenances, NFPA 24;andd) Standard for Installation of Stationary Fire Pumps for Fire Protection, NFPA 20.2 Components2.1 Except as indicated in 2.2, a compone

35、nt of a product covered by this standard shall comply with therequirements for that component.2.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this standard, or

36、b) Is superseded by a requirement in this standard.2.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.4 Specific components are incomplete in construction features or restricted in performance capabilities.Such components are intended for use

37、only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.MARCH 17, 2005INDICATING PRESSURE GAUGES FOR FIRE-PROTECTION SERVICE - UL 3934UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTI

38、ON WITHOUT PERMISSION FROM UL3 Units of Measurement3.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.4 Undated References4.1 Any undated reference to a code or standard appearing in the requirements of this standard shall beint

39、erpreted as referring to the latest edition of that code or standard.CONSTRUCTION5 General5.1 Pressure connections shall be tapered pipe threads in the 1/4 inch-18 size conforming with theStandard for Pipe Threads, General Purpose (Inch), ANSI/ASME B1.20.1.6 Sizes6.1 The size of a gauge enclosed in

40、a cylindrical case is to be the inside diameter of the case, in inches,measured at the face of the dial.6.2 The dimensions of a flush or surface mounted pressure gauge shall be as specified in Table 6.1.Table 6.1Flush and surface mounted gauge dimensionsGauge size, Mounting bolt circle diameter Case

41、 bolt hole diameter Outside diameter of flushmounted case, maximuminches inches (mm) inches (mm) inches (mm)3-1/2 4.25 (108) 0.22 (5.6) 3.75 (95.3)4-1/2 5.38 (137) 0.22 (5.6) 4.88 (124)7 Dials7.1 The range of a gauge dial shall be as specified in Table 7.1.MARCH 17, 2005 INDICATING PRESSURE GAUGES F

42、OR FIRE-PROTECTION SERVICE - UL 393 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 7.1Dial rangesTable 7.1 revised March 31, 2009Psia(kPa)-30 Inches Hg 150 (Compound type) (-100 (vacuum) 1000)0 45 to 150 (Retard Type) (0 300 to 1000)0

43、80 to 250 or 300 (Retard Type) (0 600 to 1800 or 2000)0 100 (0 600)0 150 (0 1000)0 250 (0 1600)0 300 (0 2500)0 400 (0 - 2800)0 600 (0 4000)aUnless otherwise noted7.2 The values of the minor, or smallest, graduations on the dial shall be those specified in Table 7.2.Table 7.2Value of smallest graduat

44、ionsTable 7.2 revised March 31, 2009Range GraduationsHg, inch psi (kPa) psi (kPa) Hg, inch-30 to 0 0 to 150(Compound Type)(-10001000) 5 (25) 1/2 0 to 45 (RetardType)(0 300) 1 (5) 0 to 80 (RetardType)(0 600) 2 (10) 0 to 100 (0 600) 2 (10) 0 to 150 (0 1000) 2 (10) 0 to 250 (0 1600) 5 (25) 0 to 300 (0

45、2500) 5 (25) 0 to 400 (0 2800) 10 (50) 0 to 600 (0 4000) 10 (50) 7.3 Graduations and numerals on the dial shall be sharp and legible, as produced by silvering andlacquering, etching and filling, photographic, lithographic, and other equivalent processes.7.4 Graduation lines shall be radial to the ce

46、nter of rotation of the pointer and shall project beyond thearc described by the end of the pointer. Major and intermediate graduation lines shall be emphasized.Graduations shall not extend beyond the calibrated portion of the scale.Exception: Graduation lines on a mirror dial are not required to pr

47、oject beyond the arc described by theend of the pointer.MARCH 31, 2009INDICATING PRESSURE GAUGES FOR FIRE-PROTECTION SERVICE - UL 3936UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.5 Numerals provided shall enable the operator to accurately

48、 and quickly identify any pressure on thescale. Numerals shall not obscure or crowd graduations or markings. Numerals shall not extend beyondthe calibrated portion of the scale.MARCH 31, 2009 INDICATING PRESSURE GAUGES FOR FIRE-PROTECTION SERVICE - UL 393 6AUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR

49、 FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMARCH 31, 2009INDICATING PRESSURE GAUGES FOR FIRE-PROTECTION SERVICE - UL 3936BNo Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7.6 The graduated scale shall be 270 degrees.7.7 See General, Section 22 for additional marking requirements for gauges.8 Pointers8.1 A pointer

展开阅读全文
相关资源
猜你喜欢
  • FORD WSK-M97D2-A-2006 PHENOLIC (PF) 40 % GLASS FIBER REINFORCED SHEET  TO BE USED WITH FORD WSS-M99P111-A 《40%玻璃纤维增强的酚醛树脂(PF)板  与标准FORD WSSS-M99P111-A一起使用 》.pdf FORD WSK-M97D2-A-2006 PHENOLIC (PF) 40 % GLASS FIBER REINFORCED SHEET TO BE USED WITH FORD WSS-M99P111-A 《40%玻璃纤维增强的酚醛树脂(PF)板 与标准FORD WSSS-M99P111-A一起使用 》.pdf
  • FORD WSK-M97G5-A-1989 GASKET COATING COMPOUND《涂层垫片[替代 FORD SS-M98D9780-A]》.pdf FORD WSK-M97G5-A-1989 GASKET COATING COMPOUND《涂层垫片[替代 FORD SS-M98D9780-A]》.pdf
  • FORD WSK-M98D23-A-2006 PVC METALLIZED POLYESTER FILM PVC LAMINATE DECORATIVE COEXTRUSION MOLDING  TO BE USED WITH FORD WSS-M99P1111-A 《装饰性聚氯乙烯(PVC) 金属涂覆的聚酯薄膜 聚氯乙烯(PVC)层压板共挤压成型料  与标.pdf FORD WSK-M98D23-A-2006 PVC METALLIZED POLYESTER FILM PVC LAMINATE DECORATIVE COEXTRUSION MOLDING TO BE USED WITH FORD WSS-M99P1111-A 《装饰性聚氯乙烯(PVC) 金属涂覆的聚酯薄膜 聚氯乙烯(PVC)层压板共挤压成型料 与标.pdf
  • FORD WSK-M98D24-A1-2006 FLUOROPOLYMER (PVDF) ALLOY FILM EXTERIOR  TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用含氟聚合物(PVDF)合金薄膜  与标准FORD WSS-M99P1111-A一起使用 》.pdf FORD WSK-M98D24-A1-2006 FLUOROPOLYMER (PVDF) ALLOY FILM EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用含氟聚合物(PVDF)合金薄膜 与标准FORD WSS-M99P1111-A一起使用 》.pdf
  • FORD WSK-M98D24-A2-2006 FLUOROPOLYMER (PVDF) ALLOY FILM ADHESIVE COATED EXTERIOR  TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用胶粘剂涂覆的含氟聚合物(PVDF)合金薄膜 与标准FORD WSS-M99P1111-A一起使用 列于标准WSK.pdf FORD WSK-M98D24-A2-2006 FLUOROPOLYMER (PVDF) ALLOY FILM ADHESIVE COATED EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用胶粘剂涂覆的含氟聚合物(PVDF)合金薄膜 与标准FORD WSS-M99P1111-A一起使用 列于标准WSK.pdf
  • FORD WSK-M98D24-A3-2006 FLUOROPOLYMER (PVDF) ALLOY FILM PVC FILM LAMINATE EXTERIOR  TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用含氟聚合物(PVDF)合金薄膜 聚氯乙烯(PVC)层合薄膜 与标准FORD WSS-M99P1111-A一起.pdf FORD WSK-M98D24-A3-2006 FLUOROPOLYMER (PVDF) ALLOY FILM PVC FILM LAMINATE EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用含氟聚合物(PVDF)合金薄膜 聚氯乙烯(PVC)层合薄膜 与标准FORD WSS-M99P1111-A一起.pdf
  • FORD WSK-M98D24-A4-2006 POLYVINYL FLUORIDE (PVF) FILM POLYESTER FILM PVC FILM LAMINATE EXTERIOR  TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用聚氟乙烯(PVF)薄膜 聚酯薄膜 聚氯乙烯(PVC)层合薄膜 与标准FORD WS.pdf FORD WSK-M98D24-A4-2006 POLYVINYL FLUORIDE (PVF) FILM POLYESTER FILM PVC FILM LAMINATE EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A 《汽车外部用聚氟乙烯(PVF)薄膜 聚酯薄膜 聚氯乙烯(PVC)层合薄膜 与标准FORD WS.pdf
  • FORD WSK-M98D25-A-2006 POLYPROPYLENE (PP) SHEET 50% WOOD FLOUR FILLED  TO BE USED WITH FORD WSS-M99P1111-A 《50%木屑填充的聚丙烯(PP)板 与标准FORD WSS-M99P1111-A一起使用》.pdf FORD WSK-M98D25-A-2006 POLYPROPYLENE (PP) SHEET 50% WOOD FLOUR FILLED TO BE USED WITH FORD WSS-M99P1111-A 《50%木屑填充的聚丙烯(PP)板 与标准FORD WSS-M99P1111-A一起使用》.pdf
  • FORD WSK-M98D25-A2-2006 MODIFIED POLYPROPYLENE (PP) EPDM MODIFIED SHEET 25% WOOD FLOUR FILLED VIRGIN AND OR RECYCLED POLYMER MATRIX  TO BE USED WITH FORD WSS-M99P1111-A 《使用新的和 或再生聚.pdf FORD WSK-M98D25-A2-2006 MODIFIED POLYPROPYLENE (PP) EPDM MODIFIED SHEET 25% WOOD FLOUR FILLED VIRGIN AND OR RECYCLED POLYMER MATRIX TO BE USED WITH FORD WSS-M99P1111-A 《使用新的和 或再生聚.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1