UL 60335-2-24 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf

上传人:刘芸 文档编号:1068396 上传时间:2019-04-02 格式:PDF 页数:2 大小:30.75KB
下载 相关 举报
UL 60335-2-24 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf_第1页
第1页 / 共2页
UL 60335-2-24 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(

2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): SHZZ, SHMRStandard Number: UL 60335-2-24Standard Title: Standard for Household and Similar Electrical Appliances - Safety -Part 2-24: Particular Requirements for Refrigerating Appliances, Ice-CreamApp

3、liances and Ice-MakersEdition Date: April 28, 2017Edition Number: 2Section / Paragraph Reference: 22.118DVSubject: Refrigerant Tubing ProtectionDECISION:22.118DV D2 Addition of Clauses 22.118DV.1 and 22.118DV.2 to the Part 2:22.118DV.1 Compression-type appliances which use flammable refrigerants sha

4、ll not be constructed withrefrigerant tubing on the exterior of the refrigerator such that it could be grasped or handled during movingof the appliance.Refrigerant tubing on a refrigerator employing a flammable refrigerant shall be protectedor enclosed to avoid mechanical damage and damage that coul

5、d occur during moving of the product.22.118DV.1.1 Refrigerant tubing located within the confines of the cabinet and tubing that does notprotrude from the compressor compartment is considered to be protected from mechanical damage.22.118DV.1.2 A static condenser coil mounted on the outside of a refri

6、gerator is considered to beprotected against mechanical damage if it complies with all of the following:- The return bends of the condenser are covered such that they cannot be grasped or handledduring moving of the product. The return bends are considered to be adequately covered if theycannot be g

7、rasped with test probe B applied with a force of 20 N.- The other edges of the condenser are covered or secured to prevent damage during movingof the product. They are considered adequately secured if they meet the pull force requirementsof clause 22.11 without deformation of the tubing or loosening

8、 of the condenser from therefrigerator.- All other tubing in the condenser is adequately protected by the fill wire. The tubing isconsidered adequately protected if any single tube cannot be grasped with test probe B appliedwith a force of 20 N.RATIONALE FOR DECISION:The flammable refrigerant requir

9、ements in UL 250 and UL 60335-2-24 1st edition were written such thatrefrigeration tubing should be protected to the greatest extent possible. This includes the protection ofrefrigerant tubing on the exterior of the refrigerator as well as the interior. Clause 22.117DV.3 of Edition1 contained relati

10、vely clear requirements regarding the exterior tubing. Clause 22.118DV.1 of the 2ndedition of UL 60335-2-24 is not very clear as to how this protection is to be achieved, so it has beenre-written for clarity.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMI

11、SSION FROM ULCopyright 2018 UL LLCUL LLC, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the o

12、pinion of UL LLC. in practically applying therequirements of the standard. They do not represent formal interpretations of the standard underAmerican National Standards Institute (ANSI) processes. UL LLC shall not be responsible to anyone forthe use of or reliance upon Certification Requirement Deci

13、sions by anyone. UL LLC shall not incur anyobligation or liability for damages, including consequential damages, arising out of or in connection withthe use or reliance upon Certification Requirement Decisions. The electronic version of the CertificationRequirement Decision is the current version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 60335-2-24 -2-

展开阅读全文
相关资源
猜你喜欢
  • BS EN ISO 4524-6-1989 Metallic coatings - Test methods for electrodeposited gold and gold alloy coatings - Determination of the presence of residual salts《金属镀层 电镀金和金合金镀层测试方法 残留盐类测定.pdf BS EN ISO 4524-6-1989 Metallic coatings - Test methods for electrodeposited gold and gold alloy coatings - Determination of the presence of residual salts《金属镀层 电镀金和金合金镀层测试方法 残留盐类测定.pdf
  • BS EN ISO 4527-2003 Metallic coatings Autocatalytic (electroless) nickel-phosphorus alloy coatings Specification and test methods《金属覆层 自催化(无电镀)镍磷合金覆层 规范和试验方法》.pdf BS EN ISO 4527-2003 Metallic coatings Autocatalytic (electroless) nickel-phosphorus alloy coatings Specification and test methods《金属覆层 自催化(无电镀)镍磷合金覆层 规范和试验方法》.pdf
  • BS EN ISO 4528-2015 Vitreous and porcelain enamel finishes Guide to selection of test methods for vitreous and porcelain enamelled areas of articles《釉瓷和搪瓷精饰 制件的釉瓷和搪瓷区域用试验方法的选择》.pdf BS EN ISO 4528-2015 Vitreous and porcelain enamel finishes Guide to selection of test methods for vitreous and porcelain enamelled areas of articles《釉瓷和搪瓷精饰 制件的釉瓷和搪瓷区域用试验方法的选择》.pdf
  • BS EN ISO 4534-2010 Vitreous and porcelain enamels Determination of fluidity behaviour Fusion flow test《釉瓷和搪瓷 流动性测试 熔流法》.pdf BS EN ISO 4534-2010 Vitreous and porcelain enamels Determination of fluidity behaviour Fusion flow test《釉瓷和搪瓷 流动性测试 熔流法》.pdf
  • BS EN ISO 4536-1986 Metallic and non-organic coatings on metallic substrates - Saline droplets corrosion test (SD test)《金属基片上的金属覆层和无机覆层 盐滴腐蚀试验(SD试验)》.pdf BS EN ISO 4536-1986 Metallic and non-organic coatings on metallic substrates - Saline droplets corrosion test (SD test)《金属基片上的金属覆层和无机覆层 盐滴腐蚀试验(SD试验)》.pdf
  • BS EN ISO 4541-1979 Metallic and other non-organic coatings - Corrodkote test (CORR test)《金属和其它无机物覆层 涂膏耐蚀试验(CORR试验)》.pdf BS EN ISO 4541-1979 Metallic and other non-organic coatings - Corrodkote test (CORR test)《金属和其它无机物覆层 涂膏耐蚀试验(CORR试验)》.pdf
  • BS EN ISO 4543-1995 Metallic and other non-organic coatings - General rules for corrosion tests applicable for storage conditions《金属镀层和其它无机物涂层 储存腐蚀试验一般规程》.pdf BS EN ISO 4543-1995 Metallic and other non-organic coatings - General rules for corrosion tests applicable for storage conditions《金属镀层和其它无机物涂层 储存腐蚀试验一般规程》.pdf
  • BS EN ISO 4566-1995 Small craft with inboard engine - Propeller shaft ends and bosses with 1 10 taper《舱内机小艇 锥度为1 10螺旋浆轴端和轴毂》.pdf BS EN ISO 4566-1995 Small craft with inboard engine - Propeller shaft ends and bosses with 1 10 taper《舱内机小艇 锥度为1 10螺旋浆轴端和轴毂》.pdf
  • BS EN ISO 4577-1999 Plastics - Polypropylene and propylene-copolymers - Determination of thermal oxidative stability in air - Oven method《塑料 聚丙烯和丙烯共聚物 空气中热氧化稳定性的测定 烘箱法》.pdf BS EN ISO 4577-1999 Plastics - Polypropylene and propylene-copolymers - Determination of thermal oxidative stability in air - Oven method《塑料 聚丙烯和丙烯共聚物 空气中热氧化稳定性的测定 烘箱法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1