UL 935 CRD-2012 UL Standard for Safety Fluorescent-Lamp Ballasts - Section Paragraph Reference Supplement SC (new) Subject Ballasts intended to be dimmed using solid-state dimming e .pdf

上传人:arrownail386 文档编号:1069063 上传时间:2019-04-02 格式:PDF 页数:4 大小:25.82KB
下载 相关 举报
UL 935 CRD-2012 UL Standard for Safety Fluorescent-Lamp Ballasts - Section Paragraph Reference Supplement SC (new) Subject Ballasts intended to be dimmed using solid-state dimming e .pdf_第1页
第1页 / 共4页
UL 935 CRD-2012 UL Standard for Safety Fluorescent-Lamp Ballasts - Section Paragraph Reference Supplement SC (new) Subject Ballasts intended to be dimmed using solid-state dimming e .pdf_第2页
第2页 / 共4页
UL 935 CRD-2012 UL Standard for Safety Fluorescent-Lamp Ballasts - Section Paragraph Reference Supplement SC (new) Subject Ballasts intended to be dimmed using solid-state dimming e .pdf_第3页
第3页 / 共4页
UL 935 CRD-2012 UL Standard for Safety Fluorescent-Lamp Ballasts - Section Paragraph Reference Supplement SC (new) Subject Ballasts intended to be dimmed using solid-state dimming e .pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a

2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): FKVS, FKVS7Standard Number: UL 935Edition Date: May 21, 2001Edition Number: 10Section / Paragraph Reference: Supplement SC (new)Subject: Ballasts intended to

3、 be dimmed using solid-state dimming controlselectrically wired in series with the mains supplyDECISION:SC - LINE-DIMMABLE FLUORESCENT BALLASTSSC1 ScopeSC1.1 The requirements in this supplement are applicable to ballasts that are marked or otherwiseindicated to be dimmable using a solid-state dimmin

4、g control electrically wired in series with the mainssupply.SC1.2 Ballasts with integral dimming functions controlled by external sources that do not affect the mainsvoltage powering the ballast (such as 0-10 volt dimmers, RF/carrier wave signals, etc.) shall additionallybe evaluated to the requirem

5、ents of Supplement SB.SC1.3 These requirements are not to be solely used in judging the acceptability of line-dimmable ballasts.The requirements in the main body of this Standard also apply, except as superseded by a requirementin this supplement.SC2 Normal Temperature and Abnormal Temperature Tests

6、SC2.1 The Normal Temperature test in clause 25 and the Abnormal Temperature test in clause 26, whenconducted, shall be conducted using the input power supply sources described below, in turn:a) The ballast shall be operated directly from the mains supply as required by clauses 21.6,21.7 and 21.9.b)

7、The ballast shall be operated with a single, appropriately rated semiconductor diode in series(half-wave rectification) with the ungrounded conductor of the supply described in (a).c) The ballast shall be operated with an adjustable dimmer electrically wired in series with thesupply described in (a)

8、. This dimmer shall have the following characteristics:1) It shall be an adjustable phase-cut type that does not contain any components in itsoutput circuitry for waveform smoothing,2) It shall produce an output waveform with a variable conduction angle similar to thatdepicted in Figure SC1, to be c

9、onfirmed by observing the input supply waveform to theballast using an oscilloscope; andUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3) It shall be adjusted so the input current to the ballast is at the maximum RMS valuethat the ballast can

10、 draw.Exception: A ballast marked or otherwise identified for use only with specific dimmers shall be tested withthese specified dimmers in lieu of (b) and (c). The dimmers shall be adjusted so the input current to theballast is at the maximum RMS value that the ballast can draw.This is generated te

11、xt for figtxt.SC2.2 The input and output supply conditions for each of the tests performed, including the waveform, areto be recorded. Where practical, the same sample shall be used for all tests.SC2.3 If, during any test, there are indicators of a possible fault condition (i.e.: buzzing, arcing,ove

12、rheating, smoke, smell, etc.) then that test method shall be repeated as part of the fault condition testapplicable to the ballast.SC3 MarkingsSC3.1 Ballasts that have been evaluated as dimmable in accordance with SC2 are permitted to bemarked as such on the label, instructions or both. Where evalua

13、ted only with specific dimmers, the ballastshall be clearly identified as suitable only for use with these specific dimmers, in the same location as thedimmable marking.Figure SC1Phase-cut type dimmer output waveform(See Clause SC2.1.c.2)STANDARD NUMBER: UL 935 -2-UL COPYRIGHTED MATERIAL NOT AUTHORI

14、ZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULRATIONALE FOR DECISION:This CRD provides evaluation and testing requirements when ballasts are marked or otherwise indicatedby the manufacturer to be dimmable using solid-state dimming controls electrically wired in series with th

15、emains supply.When solid-state dimming controls are used to regulate the applied voltage to ballasts, different inputvoltage waveforms (non-sinusoidal 60 Hz) may influence the outcome of certain tests required by thisstandard. Specifically, these waveforms may influence heating of components integra

16、l to the ballast. Toaddress this concern, clause SC2 provides specific criteria for the supply sources used during both normaland abnormal temperature testing.This CRD substantially follows the requirements for self-ballasted lamps - UL 1993, 3rd Edition, clause8.12 (tests of dimmer circuits).Copyri

17、ght 2012 Underwriters Laboratories Inc.UL, in performing its functions in accordance with its objectives, does not guarantee or warrant thecorrectness of Certification Requirement Decisions it may issue or that they will be recognized or adoptedby anyone. Certification Requirement Decisions are the

18、opinion of Underwriters Laboratories Inc. inpractically applying the requirements of the standard. They do not represent formal interpretations of thestandard under American National Standards Institute (ANSI) processes. UL shall not be responsible toanyone for the use of or reliance upon Certificat

19、ion Requirement Decisions by anyone. UL shall not incurany obligation or liability for damages, including consequential damages, arising out of or in connectionwith the use or reliance upon Certification Requirement Decisions. The electronic version of theCertification Requirement Decision is the cu

20、rrent version and previously printed copies may be outdated.This document is published as a service to ULs certification customersSTANDARD NUMBER: UL 935 -3-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSTANDARD NUMBER: UL 935 -4-No Text on This Page

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2729-2009(2015) Standard Practice for Rectification of Spectrophotometric Bandpass Differences《光谱光度测量的带通差异调整的标准实践规程》.pdf ASTM E2729-2009(2015) Standard Practice for Rectification of Spectrophotometric Bandpass Differences《光谱光度测量的带通差异调整的标准实践规程》.pdf
  • ASTM E2729-2016 Standard Practice for Rectification of Spectrophotometric Bandpass Differences《光谱光度测量的带通差异调整的标准实施规程》.pdf ASTM E2729-2016 Standard Practice for Rectification of Spectrophotometric Bandpass Differences《光谱光度测量的带通差异调整的标准实施规程》.pdf
  • ASTM E2730-2010 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《用于电子参比端补偿电路.pdf ASTM E2730-2010 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《用于电子参比端补偿电路.pdf
  • ASTM E2730-2010(2015)e1 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《用于电.pdf ASTM E2730-2010(2015)e1 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《用于电.pdf
  • ASTM E2730-2010(2015)e2 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《校准和.pdf ASTM E2730-2010(2015)e2 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《校准和.pdf
  • ASTM E2732-2011 Standard Practice for Responder Family Support Service《家庭支援服务应答机的标准操作规程》.pdf ASTM E2732-2011 Standard Practice for Responder Family Support Service《家庭支援服务应答机的标准操作规程》.pdf
  • ASTM E2733-2010 Standard Guide for Investigation of Equipment Problems and Releases for Petroleum Underground Storage Tank Systems《地下石油储罐系统用设备问题调查和解除的标准指南》.pdf ASTM E2733-2010 Standard Guide for Investigation of Equipment Problems and Releases for Petroleum Underground Storage Tank Systems《地下石油储罐系统用设备问题调查和解除的标准指南》.pdf
  • ASTM E2733-2010(2015) Standard Guide for Investigation of Equipment Problems and Releases for Petroleum Underground Storage Tank Systems《调查石油地下储罐系统用设备问题和发布的标准指南》.pdf ASTM E2733-2010(2015) Standard Guide for Investigation of Equipment Problems and Releases for Petroleum Underground Storage Tank Systems《调查石油地下储罐系统用设备问题和发布的标准指南》.pdf
  • ASTM E2734 E2734M-2010 Standard Specification for Dimensions of Knife-Edge Flanges《刀口法兰的尺寸用标准规范》.pdf ASTM E2734 E2734M-2010 Standard Specification for Dimensions of Knife-Edge Flanges《刀口法兰的尺寸用标准规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1