1、05-10 06 20 00 - 1 SECTION 06 20 00 FINISH CARPENTRY SPEC WRITER NOTES: 1. Delete between /_/ if not applicable to project. Also delete any other item or paragraph not applicable in the section and renumber the paragraphs. 2. Use terminology as listed and coordinate drawings to use the same term. 3.
2、 This section includes custom fabricated architectural woodwork or millwork. 4. List additional items required by the project. 5. See VA standard details, identified in list in parenthesis following item; delete detail reference from project specification. PART 1 - GENERAL 1.1 DESCRIPTION A. This se
3、ction specifies exterior and interior millwork. B. Items specified. - Seats and benches - Communication Center Counter - Folding Shelf: Dressing (Make-Up) - Counter Shelf - Interview Booth - Counter or Work Tops - Wall Paneling - Pegboard (Perforated Hardboard) - Mounting Strips, Shelves, and Rods S
4、PEC WRITER NOTE: The following items do not occur frequently and require specification paragraphs developed for project conditions. - Chair Rail - Moldings and Staff Beads - Base - Wood Bumpers 1.2 RELATED WORK A. Fabricated Metal brackets, bench supports and countertop legs: Section 05 50 00, METAL
5、 FABRICATIONS. B. Framing, furring and blocking: Section 06 10 00, ROUGH CARPENTRY. C. Wood doors: Section 08 14 00, WOOD DOORS. D. Color and texture of finish: Section 09 06 00, SCHEDULE FOR FINISHES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
6、05-10 06 20 00 - 2 E. Stock Casework: Section 12 32 00, MANUFACTURED WOOD CASEWORK. F. Other Countertops: Division 11, EQUIPMENT and Division 12, FURNISHINGS. G. Electrical light fixtures and duplex outlets: Division 26, ELECTRICAL. 1.3 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP
7、DRAWINGS, PRODUCT DATA, AND SAMPLES. B. Shop Drawings: 1. Millwork items Half full size scale for sections and details 1:50 (1/4-inch) for elevations and plans. 2. Show construction and installation. C. Samples: Plastic laminate finished plywood or particleboard, 150 mm by 300 mm (six by twelve inch
8、es). D. Certificates: 1. Indicating / preservative treatment / fire retardant treatment / of materials meet the requirements specified. 2. Indicating moisture content of materials meet the requirements specified. E. List of acceptable sealers for fire retardant and preservative treated materials. F.
9、 Manufacturers literature and data: 1. Finish hardware 2. Sinks with fittings 3. Electrical components 1.4 DELIVERY, STORAGE AND HANDLING A. Protect lumber and millwork from dampness, maintaining moisture content specified both during and after delivery at site. B. Store finishing lumber and millwor
10、k in weathertight well ventilated structures or in space in existing buildings designated by Resident Engineer. Store at a minimum temperature of 210C (700F) for not less than 10 days before installation. C. Pile lumber in stacks in such manner as to provide air circulation around surfaces of each p
11、iece. 1.5 APPLICABLE PUBLICATIONS A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only. B. American Society of Testing and Materials (ASTM): A36/A36M-08 Structural Steel A53-07 . Pipe, S
12、teel, Black and Hot-Dipped Zinc Coated, Welded and Seamless Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 3 A167-99 (R2009) Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip B26/B26M-09 Aluminum-Alloy Sand
13、Castings B221-08 Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes E84-09 . Surface Burning Characteristics of Building Materials C. American Hardboard Association (AHA): A135.4-04 Basic Hardboard D. Builders Hardware Manufacturers Association (BHMA): A156.9-03 Cabinet Hardw
14、are A156.11-04 . Cabinet Locks A156.16-02 . Auxiliary Hardware E. Hardwood Plywood and Veneer Association (HPVA): HP1-09 . Hardwood and Decorative Plywood F. National Particleboard Association (NPA): A208.1-99 Wood Particleboard G. American Wood-Preservers Association (AWPA): AWPA C1-03 . All Timber
15、 Products Preservative Treatment by Pressure Processes H. Architectural Woodwork Institute (AWI): AWI-99 . Architectural Woodwork Quality Standards and Quality Certification Program I. National Electrical Manufacturers Association (NEMA): LD 3-05 High-Pressure Decorative Laminates J. U.S. Department
16、 of Commerce, Product Standard (PS): PS20-05 American Softwood Lumber Standard K. Military Specification (Mil. Spec): MIL-L-19140E . Lumber and Plywood, Fire-Retardant Treated L. Federal Specifications (Fed. Spec.): A-A-1922A Shield Expansion A-A-1936 . Contact Adhesive FF-N-836D Nut, Square, Hexago
17、n Cap, Slotted, Castle FF-S-111D(1) . Screw, Wood MM-L-736(C) Lumber, Hardwood PART 2 - PRODUCTS 2.1 LUMBER A. Grading and Marking: 1. Lumber shall bear the grade mark, stamp, or other identifying marks indicating grades of material. Provided by IHSNot for ResaleNo reproduction or networking permitt
18、ed without license from IHS-,-,-05-10 06 20 00 - 4 2. Such identifying marks on a material shall be in accordance with the rule or standard under which the material is produced, including requirements for qualifications and authority of the inspection organization, usage of authorized identification
19、, and information included in the identification. 3. The inspection agency for lumber shall be approved by the Board of Review, American Lumber Standards Committee, to grade species used. B. Sizes: 1. Lumber Size references, unless otherwise specified, are nominal sizes, and actual sizes shall be wi
20、thin manufacturing tolerances allowed by the standard under which product is produced. 2. Millwork, standing and running trim, and rails: Actual size as shown or specified. C. Hardwood: MM-L-736, species as specified for each item. D. Softwood: PS-20, exposed to view appearance grades: 1. Use C sele
21、ct or D select, vertical grain for transparent finish including stain transparent finish. 2. Use Prime for painted or opaque finish. E. Use edge grain Wood members exposed to weather. 2.2 PLYWOOD A. Softwood Plywood: 1. Prod. Std. 2. Grading and Marking: a. Each sheet of plywood shall bear the mark
22、of a recognized association or independent inspection agency that maintains continuing control over the quality of the plywood. b. The mark shall identify the plywood by species group or identification index, and shall show glue type, grade, and compliance with PS1. 3. Plywood, 13 mm (1/2 inch) and
23、thicker; not less than five ply construction, except 32 mm (1-1/4 inch) thick plywood not less than seven ply. 4. Plastic Laminate Plywood Cores: a. Exterior Type, and species group. b. Veneer Grade: A-C. 5. Shelving Plywood: a. Interior Type, any species group. b. Veneer Grade: A-B or B-C. 6. Other
24、: As specified for item. B. Hardwood Plywood: 1. HPVA: HP.1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 5 2. Species of face veneer shall be as shown or as specified in connection with each particular item. 3. Inside of Building:
25、 a. Use Type II (interior) A grade veneer for transparent finish. b. Use Type II (interior) Sound Grade veneer for paint finish. 4. On Outside of Building: a. Use Type I, (exterior) A Grade veneer for natural or stained and varnish finish. b. Use Type I, (exterior) Sound Grade veneer for paint finis
26、h. 5. Use plain sliced red oak / rotary cut white birch / unless specified otherwise. 2.3 PARTICLEBOARD A. NPA A208.1 B. Plastic Laminate Particleboard Cores: 1. Use Type 1, Grade 1-M-3, or Type 2, Grade 2-M-2, unless otherwise specified. 2. Use Type 2, Grade 2-M-2, exterior bond, for tops with sink
27、s. C. General Use: Type 1, Grade 1-M-3 or Type 2, Grade 2-M-2. 2.4 PLASTIC LAMINATE A. NEMA LD-3. B. Exposed decorative surfaces including countertops, both sides of cabinet doors, and for items having plastic laminate finish. General Purpose, Type HGL. C. Cabinet Interiors including Shelving: Both
28、of following options to comply with NEMA, CLS as a minimum. 1. Plastic laminate clad plywood or particle board. 2. Resin impregnated decorative paper thermally fused to particle board. D. Backing sheet on bottom of plastic laminate covered wood tops: Backer, Type HGP. E. Post Forming Fabrication, De
29、corative Surfaces: Post forming, Type HGP. 2.5 BUILDING BOARD (HARDBOARD) A. ANSI/AHA A135.4, 6 mm (1/4 inch) thick unless specified otherwise. B. Perforated hardboard (Pegboard): Type 1, Tempered perforated 6 mm (1/4 inch) diameter holes, on 25 mm (1 inch) centers each way, smooth surface one side.
30、 C. Wall paneling at gas chain rack: Type 1, tempered, Fire Retardant treated, smooth surface on side. 2.6 ADHESIVE A. For Plastic Laminate: Fed. Spec. A-A-1936. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 6 B. For Interior Millw
31、ork: Unextended urea resin, unextended melamine resin, phenol resin, or resorcinol resin. C. For Exterior Millwork: Unextended melamine resin, phenol resin, or resorcinol resin. 2.7 STAINLESS STEEL ASTM A167, Type 302 or 304. 2.8 ALUMINUM CAST ASTM B26 2.9 ALUMINUM EXTRUDED ASTM B221 2.10 HARDWARE A
32、. Rough Hardware: 1. Furnish rough hardware with a standard plating, applied after punching, forming and assembly of parts; galvanized, cadmium plated, or zinc-coated by electric-galvanizing process. Galvanized where specified. 2. Use galvanized coating on ferrous metal for exterior work unless non-
33、ferrous metals or stainless is used. 3. Fasteners: a. Bolts with Nuts: FF-N-836. b. Expansion Bolts: A-A-1922A. c. Screws: Fed. Spec. FF-S-111. SPEC WRITER NOTE: Add additional finish hardware when required from ANSI A156.9 and A156.16. B. Finish Hardware 1. Cabinet Hardware: ANSI A156.9. a. Door/Dr
34、awer Pulls: B02011. Door in seismic zones: B03182. b. Drawer Slides: B05051 for drawers over 150 mm (6 inches) deep, B05052 for drawers 75 mm to 150 mm 3 to 6 inches) deep, and B05053 for drawers less than 75 mm (3 inches) deep. c. Sliding Door Tracks: B07063. d. Adjustable Shelf Standards: B4061 wi
35、th shelf rest B04083. e. Concealed Hinges: B1601, minimum 110 degree opening. f. Butt Hinges: B01361, for flush doors, B01381 for inset lipped doors, and B01521 for overlay doors. g. Cabinet Door Catch: B0371 or B03172. h. Vertical Slotted Shelf Standard: B04103 with shelf brackets B04113, sized for
36、 shelf depth. 2. Cabinet Locks: ANSI A156.11. a. Drawers and Hinged Door: E07262. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 7 b. Sliding Door: E07162. 3. Auxiliary Hardware: ANSI A156.16. a. Shelf Bracket: B04041, japanned or e
37、nameled finish. b. Combination Garment rod and Shelf Support: B04051 japanned or enamel finish. c. Closet Bar: L03131 chrome finish of required length. d. Handrail Brackets: L03081 or L03101. 1) Cast Aluminum, satin polished finish. 2) Cast Malleable Iron, japanned or enamel finish. 4. Steel Channel
38、 Frame and Leg supports for Counter top. Fabricated under Section 05 50 00, METAL FABRICATIONS. 5. Pipe Bench Supports: a. Pipe: ASTM A53. 6. Fabricated Wall Bench Supports: a. Steel Angles: ASTM A36 steel with chrome finish, or ASTM A167, stainless steel with countersunk wood screws, holes at 64 mm
39、 (2-1/2 inches) on center on horizontal member. b. Use 38 mm by 38 mm by 5 mm (1-1/2 by 1-1/2 by 3/16 inch) angle thick drilled for screw and bolt holes unless shown otherwise. Drill 6 mm (1/4 inch) holes for anchors on vertical member, not more than 200 mm (8 inches) on center between ends or corne
40、rs. c. Stainless steel bars brackets: ASTM A167, fabricated to shapes shown, Number 4 finish. Use 50 mm by 5 mm (2 inch by 3/16 inch) bars unless shown otherwise. Drill for anchors and screws. Drill countersunk wood screw holes at 64 mm (2-1/2 inches) on center on horizontal members and not less tha
41、n two 13 mm (1/4 inch) hole for anchors on vertical member. 7. Thru-Wall Counter Brackets: a. Steel angles drilled for fasteners on 100 mm (4 inches) centers. b. Baked enamel prime coat finish. 8. Folding Shelf Bracket: a. Steel Shelf bracket, approximately 400 mm by 400 mm (16 by 16 inches), foldin
42、g type with baked gray enamel finish or chrome plated finish. b. Bracket legs shall be approximately 28 mm (1-1/8 inches) wide. c. Distance from center line of hinge pin to back of vertical leg shall be 44 mm (1-3/4 inches) or provide for wood spacer if hinge line is at joint of vertical and horizon
43、tal leg. d. Distance from face to face of bracket when closed shall be 50 mm (2 inches). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-05-10 06 20 00 - 8 e. Brackets shall automatically lock when counter is raised parallel to floor and shall unlock
44、 manually. f. Each bracket shall support not less than 68 Kg (150 pounds) evenly distributed. 9. Edge Strips Moldings: a. Driven type “T“ shape with serrated retaining stem; vinyl plastic to match plastic laminate color, stainless steel, or 3 mm (1/8 inch) thick extruded aluminum. b. Stainless steel
45、 or extruded aluminum channels. c. Stainless steel, number 4 finish; aluminum, mechanical applied medium satin finish, clear anodized 0.1 mm (0.4 mils) thick. 10. Rubber or Vinyl molding a. Rubber or vinyl standard stock and in longest lengths practicable. b. Design for closures at joints with walls
46、 and adhesive anchorage. c. Adhesive as recommended by molding manufacturer. 11. Primers: Manufacturers standard primer for steel providing baked enamel finish. 2.11 MOISTURE CONTENT A. Moisture content of lumber and millwork at time of delivery to site. 1. Interior finish lumber, trim, and millwork
47、 32 mm (1-1/4 inches) or less in nominal thickness: 12 percent on 85 percent of the pieces and 15 percent on the remainder. 2. Exterior treated or untreated finish lumber and trim 100 mm (4 inches) or less in nominal thickness: 15 percent. 3. Moisture content of other materials shall be in accordanc
48、e with the standards under which the products are produced. SPEC WRITER NOTE: Clearly identify in the text items or parts to receive fire retardant treatment. Verify species specified is possible to be treated; many can not. 2.12 FIRE RETARDANT TREATMENT A. Where wood members and plywood are specifi
49、ed to be fire retardant treated, the treatment shall be in accordance with Mil. Spec. MIL-L19140. B. Treatment and performance inspection shall be by an independent and qualified testing agency that establishes performance ratings. C. Each piece of treated material shall bear identification of the testing agency and shall indicate performance in accordance with such rating o