IEC 60457-3-1980 Rigid precision coaxial lines and their associated precision connectors Part 3 14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial .pdf

上传人:cleanass300 文档编号:1234593 上传时间:2019-08-24 格式:PDF 页数:18 大小:1,022KB
下载 相关 举报
IEC 60457-3-1980 Rigid precision coaxial lines and their associated precision connectors Part 3  14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial .pdf_第1页
第1页 / 共18页
IEC 60457-3-1980 Rigid precision coaxial lines and their associated precision connectors Part 3  14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial .pdf_第2页
第2页 / 共18页
IEC 60457-3-1980 Rigid precision coaxial lines and their associated precision connectors Part 3  14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial .pdf_第3页
第3页 / 共18页
IEC 60457-3-1980 Rigid precision coaxial lines and their associated precision connectors Part 3  14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial .pdf_第4页
第4页 / 共18页
IEC 60457-3-1980 Rigid precision coaxial lines and their associated precision connectors Part 3  14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial .pdf_第5页
第5页 / 共18页
点击查看更多>>
资源描述

1、NORME INTERNATIONALE INTERNATIONAL STANDARD CE1 IEC 60457-3 Deuxime dition Second edition 1980-01 Lignes coaxiales rigides de prcision et leurs connecteurs de prcision associs Troisime partie: Ligne coaxiale rigide de prcision de 14 mm et connecteur coaxial de prcision hermaphrodite associ - Impdanc

2、es caractristiques 50 ohms et 75 ohms Rigid precision coaxial lines and their associated precision connectors Part 3: 14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial connector - Characteristic impedances 50 ohms and 75 ohms Numro de rfrence Reference number CEI/IEC

3、 60457-3: 1980 Numros des publications Depuis le ler janvier 1997, les publications de la CE1 sont numrotes partir de 60000. Publications consolides Les versions consolides de certaines publications de la CE1 incorporant les amendements sont disponibles. Par exemple, les numros ddition 1.0, 1.1 et 1

4、.2 indiquent respectivement la publication de base, la publication de base incorporant lamendement 1, et la publication de base incorporant les amendements 1 et 2. Validit de la prsente publication Le contenu technique des publications de la CE1 est constamment revu par la CE1 afin quil reflte ltat

5、actuel de la technique. Des renseignements relatifs la date de reconfirmation de la publication sont disponibles dans le Catalogue de la CEI. Les renseignements relatifs des questions ltude et des travaux en cours entrepris par le comit technique qui a tabli cette publication, ainsi que la liste des

6、 publications tablies, se trouvent dans les documents ci- dessous: Site web, de la CEl* Catalogue des publications de la CE1 Publi annuellement et mis jour rgulirement (Catalogue en ligne) Disponible la fois au site web de la CEI et comme priodique imprim Bulletin de la CE1 Terminologie, symboles gr

7、aphiques et littraux En ce qui concerne la terminologie gnrale, le lecteur se reportera la CE1 60050: Vocabulaire Electro- technique International (VEI). Pour les symboles graphiques, les symboles littraux et les signes dusage gnral approuves par la CEI, le lecteur consultera la CE1 60027: Symboles

8、littraux A utiliser en lectrotechnique, la CE1 6041 7: Symboles graphiques utilisables sur le matriel. Index, relev et compilation des feuilles individuelles, et la CE1 60617: Symboles graphiques pour schmas. * Voir adresse 4te web sur la page de titre. Numbering As from 1 January 1997 all IEC publi

9、cations are issued with a designation in the 60000 series. Consolidated publications Consolidated versions of some IEC publications including amendments are available. For example, edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the base publication incorporating amend

10、ment 1 and the base publication incorporating amendments 1 and 2. Validity of this publication The technical content of IEC publications is kept under constant review by the IEC, thus ensuring that the content reflects current technology. Information relating to the date of the reconfirmation of the

11、 publication is available in the IEC catalogue. Information on the subjects under consideration and work in progress undertaken by the technical committee which has prepared this publication, as well as the list of publications issued, is to be found at the following IEC sources: IEC web site* Catal

12、ogue of IEC publications Published yearly with regular updates (On-line catalogue)* Available both at the IEC web site* and as a printed periodical IEC Bulletin Terminology, graphical and letter symbols For general terminology, readers are referred to I EC 60050: International Electrotechnical Vocab

13、ulary (IEV). For graphical symbols, and letter symbols and signs approved by the IEC for general use, readers are referred to publications IEC 60027: Letter symbols to be used in electrical technology3 IEC 60417: Graphical symbols for use on equipment. Index, survey and compilation of the single she

14、ets and IEC 60617: Graphical symbols for diagrams. * See web site address on title page. NORME INTERNATIONALE INTERNATIONAL STANDARD CE1 IEC 60457-3 Deuxime dition Second edition 1980-01 Lignes coaxiales rigides de prcision et leurs connecteurs de prcision associs Troisime partie: Ligne coaxiale rig

15、ide de prcision de 14 mm et connecteur coaxial de prcision hermaphrodite associ - Impdances caractristiques 50 ohms et 75 ohms Rigid precision coaxial lines and their associated precision connectors Part 3: 14 mm rigid precision coaxial line and associated hermaphroditic precision coaxial connector

16、- Characteristic impedances 50 ohms and 75 ohms O IEC 1980 Droits de reproduction rservs - Copyright - all rights reserved Aucune partie de cette publication ne peut tre reproduite ni No part of this publication may be reproduced or utilized in utilise sous quelque forme que ce soit et par aucun any

17、 form or by any means, electronic or mechanical, procd, lectronique ou mcanique, y compris la photo- including photocopying and microfilm. without permission in copie et les microfilms, sans laccord crit de Iditeur. writing from the publisher. international Electrotechnical Commission Telefax: +41 2

18、2 919 0300 3, rue de Varemb Geneva, Switzerland IEC web site http: /www.iec.ch e-mail: inmailiec.ch G CODE PRIX PRICE CODE Pour prix, voir catalogue en vigueur For price, see current catalogue Commission Electrotechnique Internationale International Electrotechnical Commission MemnvHaponHafi 3nenpor

19、exnrecnan HOMHCCHR O -2- COMMISSION LECTROTECHNIQUE INTERNATIONALE LIGNES COAXIALES RIGIDES DE PRCISION ET LEURS CONNECTEURS DE PRCISION ASSOCIS Troisime partie : Ligne coaxiale rigide de prcision de 14 mm et connecteur coaxial de prcision hermaphrodite associ - Impdances caractristiques 50 ohms et

20、75 ohms PRAMBULE 1) Les dcisions ou accords officiels de la CE1 en ce qui ccncerne les questicns techniques, prpars par des Comits #Etudes o sont reprsents tous les Comits nationaux sintressant ces questions, expriment dans la plus grande mesure possible un accord international sur les sujets examin

21、s. 2) Ces dcisions constituent des recommandations internationales et sont agres comme telles par les Comits nationaux. 3) Dans le but dencourager Iunificaticn internationale, la CE1 exprime le vu que tous les Comits nationaux adoptent dans leurs rgles nationales le texte de la reccmmandation de la

22、CEI, dans la mesure O les conditions nationales le permettent. Toute divergence entre la reccmmandation de la CE1 et la rgle nationale correspondante doit, dans la mesure du possible, tre indique en termes clairs dans cette dernire. PRFACE La prsente norme a t prpare par le Sous-Comit 46D: Connecteu

23、rs pour cbles pour frquences radiolectriques, du Comit dEtudes NO 46 de la CE I : Cbles, fils et guides dondes pour quipements de tlcommunications. Elle constitue la troisime partie: Ligne coaxiale rigide de prcision de 14 mm et connecteur coaxial de prcision hermaphrodite associ - Impdances caractr

24、istiques 50 R et 75 R, de la norme complte sur les lignes coaxiales rigides de prcision et leurs connecteurs de prcision associs, et il convient de lutiliser avec la premire partie : Rgles gnrales et mthodes de mesure. La deuxime dition est un complment la premire dition qui ne sappliquait qu un con

25、necteur dimpdance caractristique 50 IR ; ce complment concerne un connecteur de mme caractristique mais dont limpdance caractristique est gale 75 IR. Un premier projet pour la version 75 IR fut examin lors de la runion tenue Florence en 1978. A la suite de cette runion, un projet, document 46D(Burea

26、u Central)%, fut soumis lapprobation des Comits nationaux suivant la Rgle des Six Mois en dcembre 1978. Les Comits nationaux des pays suivants se sont prononcs explicitement en faveur de la publication: Allemagne Autriche Belgique Core (Rpublique de) Espagne Etats-Unis dAmrique EuPte France Italie J

27、apon Roumanie Sude Suisse Turquie Autre publication de la CE I citie dans la prsente norme : Publication no 68-1 : Essais fondamentaux climatiques et de robustesse mcanique, Premire partie: Gnralits. -3- INTERNATIONAL ELECTROTECHNICAL COMMISSION RIGID PRECISION COAXIAL LINES AND TKEIR ASSOCIATED PRE

28、CISION CONNECTORS Part 3 : 14 mm rigid precision coaxial line impedances 50 ohms and 75 ohms and associated hermaphroditic precision coaxial connector - Characteristic FOREWORD The formal decisions or agreements of tha IEC on technical matters, prepared by Technical Committees on which all the Natio

29、nal Committees having a sprcial interest thrrein are represented, express, as nearly as possible, an international consensus of opinion on the subjects dealt with. They have the form of recommendations for international use and they are accepted by the National Committees in that sense. In order to

30、promote international unification, the IEC expresses the wish that all National Committees should adopt the text of the IEC recommendation for their national rules in so far as nation31 conditions will permit. Any divergence between the IEC recommendation and the corresponding national rules should,

31、 as far as possible, be clearly indicated in the latter. PREFACE This standard has been prepared by Sub-committee 46D: Connectors for R.F. Cables, of I E C Technical Committee No. 46 : Cables, Wires and Waveguides for Telecommunication Equipment. It forms Part 3 : 14 mm Rigid Precision Coaxial Line

32、and Associated Hermaphroditic Precision Coaxial Connector - Characteristic Impedances 50 R and 75 R, of the complete standard on rigid precision coaxial lines and their associated precision connectors, and is intended to be used in conjunction with Part 1 : General Requirements and Measuring Methods

33、. The second edition resulted from the addition to the first edition, which was restricted to a connector with a characteristic impedance of 50 R, of a connector of the same general design but with a characteristic impedance of 75 R. A first draft for the 75 !2 version was discussed at the meeting h

34、eld in Florence in 1978. As a result of this meeting, a draft, Document 46D(Central Office)%, was submitted to the National Committees for approval under the Six Months Rule in December 1978. The National Committees of the following countries voted explicitly in favour of publication : Austria Korea

35、 (Republic of) Belgium Romania Egypt Spain France Sweden Germany Switzerland Italy Turkey Japan United States of America Other IEC publication quoted in this standard: Publication No. 68-1 : Basic Environmental Testing Procedures, Part 1 : General. -4- LIGNES COAXIALES RIGIDES DE PRCISION ET LEURS C

36、ONNECTEURS DE PRCISION ASSOCIS Troisime partie : Ligne coaxiale rigide de prcision de 14 mm et connecteur coaxial de prcision hermaphrodite associ - Impdances caractristiques 50 ohms et 75 ohms Article et paragraphe de la Publication de la CE1 457-1 3.1.7.2 3.1.15 4. 5. 22. 23. Dsignation Frquence m

37、aximule La frquence maximale laquelle le facteur de rflexion et laffaiblissement sont mesurs est: - pour 50 SZ: 8,5 GHz; - pour 75 !2: 9,5 GHz. Longueur lectrique La longueur lectrique, exprime en millimtres, dune paire de connecteurs doit tre spcifie par le fabricant. Limprcision de la mesure ne do

38、it pas tre suprieure 0,05 mm (0,002 in). Dsignation de type A ltude. Conditions atmosphriques normales dessais En fonctionnement Les performances des dispositifs dassemblage doivent tre conformes aux exigences lectriques spcifies dans toute la gamme des conditions denvironnement de la Publication 68

39、-1 de la CE I: Essais fondamentaux climatiques et de robustesse mcanique, Premire partie: Gnralits, paragraphe 5.3. Prescriptions climatiques Chaleur sche Froid En stockage Aprs exposition aux conditions climatiques prcises dans la Publication 457-1 de la CE I : Lignes coaxiales rigides de prcision

40、et leurs connecteurs de prcision asso- cis, Premire partie: Rgles gnrales et mthodes de mesure, section quatre, les performances des dispositifs, mesures dans les conditions normales de fonctionne- ment, doivent rester conformes aux spcifications lectriques et mcaniques. Les svrits suivantes sont ap

41、pliques : essai A : - 55 OC; essai B : + 70 OC. -5- RIGID PRECISION COAXIAL LINES AND THEIR ASSOCIATED PRECISION CONNECTORS Part 3 : 14 mm rigid precision coaxial line impedances 50 ohms and 75 ohms and associated hermaphroditic precision coaxial connector - Characteristic Clause and sub-clause of I

42、EC Publication 457-1 3.1.7.2 3.1.15 4. 5. 22. 23. Item Maximum frequency The maximum frequency at which the reflection factor and attenuation are measured is: - for 50 Q: 8.5 GHz; - for 75 Q: 9.5 GHz. Electrical length The electrical length, expressed in millimetres, of a connector pair shall be spe

43、cified by the manufacturer. The inaccuracy of the measurement shall be not more than 0.05 mm (0.002 in). Type designation Under consideration. Standard atmospheric conditions for testing Operating The performance of the assemblies shall comply with the specified electrical require- ments over the ra

44、nge of environmental conditions specified in I E C Publication 68-1 : Basic Environmental Testing Procedures, Part 1 : General, Sub-clause 5.3. Environmental requirements Dry heat Cold Non-operating The performance of the assemblies shall remain within the electrical and mechanical specifications wh

45、en tested under normal operating conditions, after having been exposed to the environmental conditions specified in I E C Publication 457-1 : Rigid Precision Coaxial Lines and Their Associated Precision Connectors, Part 1 : General Requirements and Measuring Methods, Section Four. The following seve

46、rities apply : Test A : - 55 OC; Test B : + 70 OC. -6- Article et paragraphe de la Publication de la CE1 457-1 8. 10.1 11. 12. Dsignation Dimensions Les dimensions en millimtres sont traduites des dimensions originales en inches. Le diamtre intrieur nominal du conducteur extrieur doit tre de 14,2875

47、 mm (0,5625 in). Les tolrances maximales sur les diamtres intrieurs et extrieurs doivent limiter limprcision de limpdance caractristique : - pour 50 52 0,1% ou moins, - pour 75 52 0,2% ou moins, avec une tolrance maximale sur le diamtre intrieur du conducteur extrieur de - - pour 75 Q: 4,088 mm (0,1

48、60 95 in). Les dimensions doivent tre aussi vrifies aprs avoir effectu les essais selon la Publication 457-1 de la C E I en tenant compte de la section quatre. Pour les dimensions critiques des faces daccouplement ou des parties mcaniques daccouplement, se reporter aux figures 1 et 2, pages 12 et 13. Force du contact central des connecteurs hermaphrodites accoupls Quand deux connecteurs sont accoupls, la force axiale exerce par le mcanisme de contact sur le conducteur central dun connecteur doit tre de: - pour 50 Q: 9,0 N max. et 4,O N min.; - pour 75 Q : 11 ,O N max. et 7

展开阅读全文
相关资源
  • IEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdfIEC TS 62492-1-2008 Industrial process control devices - Radiation thermometers - Part 1 Technical data for radiation thermometers《工业过程控制装置 辐射温度计 第1部分 辐射温度计的技术数.pdf
  • IEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdfIEC TR2 61464-1998 Insulated bushings - Guide for the interpretation of dissolved gas analysis (DGA) in bushings where oil is the impregnating medium of the mai.pdf
  • IEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdfIEC TR 61241-2-2-1993 Electrical apparatus for use in the presence of combustible dust part 2 test methods section 2 method for determining the electrical resis.pdf
  • IEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdfIEC TR 60972-1989 Classification and interpretation of new lighting products《新型照明产品的分类和说明》.pdf
  • IEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdfIEC TR 60943 Edition 21-2009 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals《特殊终端中电气设备部件用关于允许.pdf
  • IEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdfIEC TR 60943 AMD 1-2008 Guidance concerning the permissible temperature rise for parts of electrical equipment in particular for terminals Amendment 1《电气设备部件(特别.pdf
  • IEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdfIEC TR 60919-2-2008 Performance of high-voltage direct current (HVDC) systems with line-communicated converters - Part 2 Faults and switching《带线性通信转换器的高压直流(HVDC.pdf
  • IEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdfIEC TR 60870-6-505 Edition 11-2006 Telecontrol equipment and systems - Part.6-505 Telecontrol protocols compatible with ISO standards and ITU-T recommendations .pdf
  • IEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdfIEC TR 60344 CORR1-2012 Calculation of d c resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide Corrigendum 1《.pdf
  • IEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdfIEC 62560 CORR1-2012 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications Corrigendum 1《普通照明用50 V以上自镇流LED灯 安全要求 勘误表1》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > IEC

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1