ASTM E2726E2726M-12a(2017) Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands.pdf

上传人:孙刚 文档编号:287104 上传时间:2019-07-10 格式:PDF 页数:7 大小:206.03KB
下载 相关 举报
ASTM E2726E2726M-12a(2017) Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands.pdf_第1页
第1页 / 共7页
ASTM E2726E2726M-12a(2017) Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands.pdf_第2页
第2页 / 共7页
ASTM E2726E2726M-12a(2017) Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands.pdf_第3页
第3页 / 共7页
ASTM E2726E2726M-12a(2017) Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands.pdf_第4页
第4页 / 共7页
ASTM E2726E2726M-12a(2017) Standard Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: E2726/E2726M 12a (Reapproved 2017)Standard Test Method forEvaluating the Fire-Test-Response of Deck Structures toBurning Brands1This standard is issued under the fixed designation E2726/E2726M; the number immediately following the designation indicates the yearof original adoption or, i

2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method determines the fire-test-response char-acteristics of deck struct

3、ures attached to or in close proximityto primary structures. The burning brand exposures test isintended to determine the degradation modes of deckingmaterials when exposed to a burning brand on the uppersurface of a deck structure.1.2 The use of paints, coatings, stains, or other surfacetreatments

4、for fire protection purposes are beyond the scope ofthis test method. This test method excludes the use of paints,stains, or coatings for this fire-test-response determination.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ine

5、ach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard is used to measure and describe theresponse of materials, products, or assemblies to heat and

6、flame under controlled conditions, but does not by itselfincorporate all factors required for fire-hazard or fire-riskassessment of the materials, products, or assemblies underactual fire conditions.1.5 Fire testing of products and materials is inherentlyhazardous. Adequate safeguards for personnel

7、and propertyshall be employed in conducting these tests.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine

8、the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations is

9、sued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D2898 Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire TestingD6662 Specification for Polyolefin-Based Plastic LumberDecking BoardsD7032 Specification

10、 for Establishing Performance Ratingsfor Wood-Plastic Composite and Plastic Lumber DeckBoards, Stair Treads, Guards, and HandrailsE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE108 Test Methods for Fire Tests of Roof CoveringsE176 Terminology of Fire Standards2.2 ICC Evalua

11、tion Services, Inc.:3AC 109 Acceptance Criteria for Thermoplastic CompositeLumber ProductsAC 174 Acceptance Criteria for Deck Board Span Ratingsand Guardrail Systems (Guards and Handrails)3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology E176.3.2 Def

12、initions of Terms Specific to This Standard:3.2.1 deck structure, nexterior structures comprised ofdeck boards or panels, stair treads, risers, and landings ofdecks, porches, and balconies.3.2.2 test material, nmembers that constitute the exposedsurface of the deck structures.4. Significance and Use

13、4.1 This test method is intended to establish the test protocolfor decking materials and systems. This test method is intended1This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.14 on External FireExposures.Current e

14、dition approved Dec. 15, 2017. Published December 2017. Originallyapproved in 2012. Last previous edition approved in 2012 as E2726/E2726M12a.DOI:10.1520/E2726_E2726M12AR17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For A

15、nnual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Code Council Evaluation Service, 5600 WorkmanMill Road, Whittier, CA.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1

16、9428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Tec

17、hnical Barriers to Trade (TBT) Committee.1to address a fire caused by exterior sources that involves theupper surface of the deck or structure.4.2 This test is a practical assessment of fire-test-responsecharacteristics under a prescribed fire loading. This test methodis a variation of Test Method E

18、108.5. Test Apparatus5.1 The essential elements of the fire test apparatus areillustrated in Fig. 1. They include a test deck, an adjustableframe on which the test deck is mounted, a wind tunnel, an airvelocity meter with or without the use of a timing device andan adjustable air supply. During the

19、test:5.1.1 Provide free outlet to outside air beyond and above thetest apparatus to exhaust air introduced into the test room bythe blower, and5.1.2 Close all openings into the test room other than thosementioned in 5.1.1, such as doors and windows.5.2 The temperature of the air supplied by the blow

20、er shallbe maintained between 10 and 32C 50 and 90F.5.3 Wind Tunnel (see Fig. 1)The wind tunnel shall deliver5.3 6 0.2 m/s 12 6 0.5 mph airflow at zero incline over thewidth of the test specimen. Test Method E108 Burning BrandRoof Test apparatus shall be used, with the following modifi-cations:5.3.1

21、 Test Specimen SupportThe test specimen shall besupported horizontally with its leading edge 838.2 mm 33 in.from the front opening of the wind tunnel with the joistsparallel to the airflow and resting on two transverse metalsupports. The top surfaces of these supports, which shall be nomore than 76

22、mm 3 in. wide, are at the same height as thefloor of the wind tunnel.5.3.2 FragmentsBurning fragments shall be free to fall tothe floor of the room.5.4 AnemometerAdevice for measuring airflow across thedeck shall be provided.NOTE 1Any direct reading instrument with scale graduated inincrements of no

23、t more than 6 m/min 20 ft/min or any timed instrumentwith scale graduated (for a 1 min timed reading) in increments of not morethan 1.5 m/min (5 ft/min) will be suitable.5.5 BurnerGas-fueled burner for brand ignition. Theflame temperature of the igniting flame shall be 888 6 28C1630 6 50F measured 5

24、9 mm 2516 in. above the top of theburner, which is shielded from drafts.6. Test Specimens (see Fig. 2)6.1 The test specimen shall consist of joists as specified in6.3 and test material as specified in 6.4.6.2 Test Specimen SizeThe overall size of the test speci-men shall be nominally 610 by 710 mm 2

25、4 by 28 in. Theoverall test specimen length (that is, direction of joists) shall be710 6 51 mm 28 6 2 in. to accommodate variations in thetest materials individual deck board width; the length of thetest material shall be 610 6 4mm246316 in.6.3 JoistsThe test material shall be supported by twonomina

26、l 50 by 150 mm 2 by 6-in. joists running perpendicu-lar to the test materials deck boards with a 406 6 4mm16in. center-to-center spacing, creating a 90 6 4 mm 3.5 6 0.16in. overhang on the outer side of each edge joist. Joist lengthshall meet the requirements specified in 6.2.6.4 Test Material:6.4.1

27、 All test materials shall be representative of the as-manufactured product including the cross sectional dimen-sions.6.4.2 Test material shall be sampled to meet the intendedend-use of the test data.6.4.3 Prior to testing, all test material and joists shall beconditioned to a constant weight or for

28、a minimum of 30 daysat 21 6 2C 70 6 4F and 50 % RH 6 5 %, whichever comesfirst. Constant weight shall be defined as a change in testmaterial weight less than or equal to2%ina24-h period.6.4.4 Edge-to-edge spacing and method of attachment shallconform to the manufacturers installation recommendations

29、.The test material shall be flush with the ends of the joists at thefront of the test specimen (that is, the edge of the test specimenfacing the front opening of the wind tunnel). Test material atthe back of the test specimen (that is, the edge of the testspecimen furthest away from the front openin

30、g of the windFIG. 1 Deck Structure Test Specimen and Test Apparatus (Burning-Brand)E2726/E2726M 12a (2017)2tunnel) manufactured with tongue-and-groove edge connec-tions shall be spaced and attached according to the manufac-turers recommendations.7. Calibration7.1 Calibrating Air Current:7.1.1 Set up

31、 the test apparatus and position a smooth deck,1.3 m 4 ft-4 in. long on the framework at a 127 mm per 304.8mm 5 in. per 12 in. horizontal incline.7.1.2 Measure the air velocity at the center and 76 mm 3in. from the edges of the deck.7.1.3 Position the center of the air measuring device 95 6 3mm 334

32、618 in. above the surface. The air flow through andaround the instrument shall be as free and undisturbed aspossible.7.1.4 Adjust the air supply to produce a 1 min timed averagevelocity of 5.3 6 0.2 m/s 12 6 0.5 mph at each of threelocations detailed in 7.1.2.8. Procedure8.1 Conduct this test on thr

33、ee replicate test specimens.FIG. 2 Test SpecimenE2726/E2726M 12a (2017)38.2 Mount each test specimen in the manner described in5.1.1 with the framework 838.2 mm 33 in. from the air ductoutlet.8.3 Size and Construction of BrandsConstruct each brand(Fig. 3), as follows, and condition in an oven at 41

34、to 49C105 to120F for at least 24 h.8.3.1 The Class A test Brand shall consist of a grid 305 mm12 in. square and approximately 57 mm 214 in. thick madeof oven dry Douglas fir lumber free of knots and pitch pockets.Use 36 nominal 25 by 25 by 305 mm 1 by 1 by 12 in. strips,dressed on all four sides to

35、19 by 19 mm 34 by34 in. andplaced in three layers of twelve strips each with strips spaced6.35 mm 14 in. apart. Place these strips at right angles to thosein adjoining layers and nail (Note 2) at each end of each stripon one face (Fig. 3). The dry weight of the finished brand shallbe 2000 6 150 g at

36、 the time of test.8.3.2 The Class B test brand shall consist of a grid 152 mm6 in. square and approximately 57 mm 214 in. thick made ofdry Douglas fir lumber free of knots and pitch pockets. Use 18nominal 25 by 25 by 152 mm 1 by 1 by 6 in. strips, dressedon all four sides to 19 by 19 mm 34 by34 in.,

37、 and placed inthree layers of six strips each with strips spaced 6.35 mm (14in. apart. Place these strips at right angles to those in adjoininglayers and nail (Note 2) at each end of each strip on one face(Fig. 3). The dry weight of the finished brand shall be 500 6150 g at the time of test.NOTE 2Na

38、ils used in the construction of ClassAand B brands are No.16, 38 mm 112 in. long bright, flat head, diamond point, wire nails. 68nails weighing approximately 42 g are used for Class A brand. 32 nailsweighing approximately 21 g are used for Class B brand.8.4 Ignition of BrandBefore application to the

39、 testspecimen, the brand shall be ignited by subjecting it, for thefollowing required periods of time, to the flame of a gas burnerof such size that, during the process of ignition, the brands areenveloped in the burner flame. The flame temperature of theigniting flame shall be 888 6 28C 1630 6 50F

40、measured59 mm 2516 in. above the top of the burner, which is shieldedfrom drafts.8.4.1 Expose Class A test brand to the flame for 5 min,during which time it shall be rotated to present each surface tothe flame in the following manner and sequence: Each 305 by305-mm 12 by 12-in. face for 30 s, each 5

41、7 by 305-mm 214by 12-in. face for 45 s, and each 305 by 305-mm 12 by12-in. face again for 30 s.8.4.2 Expose Class B test brand to the flame for 4 min,during which time they shall be rotated to present each surfaceto the flame in the following manner and sequence: Each 152by 152-mm 6 by 6-in. face fo

42、r 30 s, each 57 by 152-mm 214by 6-in. face for 30 s, and each 152 by 152-mm 6 by 6-in.face again for 30 s.8.5 Brand Placement:8.5.1 Class A BrandPlace a brand on the surface of eachtest deck at the location considered most vulnerable (point ofminimum coverage over deck joint) with respect to ignitio

43、n ofthe deck but in no case closer than 101 mm 4 in. from eitherside or 305 mm 12 in. from the edge of the deck closest to thewind source. Place the brand so that the strips in both the upperand bottom layers are parallel to the direction of air flow andwith the upper edge of the brand located 76 mm

44、 3 in. abovethe horizontal joint in the test deck. Secure to the deck by a No.18B&Sgage soft iron wire.8.5.2 Class B BrandPlace a brand on the surface of thetest deck at the location considered most vulnerable (point ofminimum coverage over deck joint) with respect to ignition ofthe deck. Position t

45、he brand with its upper edge 38 mm 112in. above the selected joint in the deck boards, but in no casecloser than 152 mm 6 in. from each side or 305 mm 12 in.from the edge of the deck closest to the wind source. Place theFIG. 3 Class A & B BrandsE2726/E2726M 12a (2017)4brand so that the bottom layers

46、 are parallel to the direction ofair flow. Secure to the deck by a 1.02 mm No. 18B&Sgagesoft iron wire.8.6 Duration of TestContinue the exposure until the brandis totally consumed and until all evidence of flame, glow andsmoke has disappeared from both the exposed surface of thetest material and the

47、 underside of the test material, but not formore than 112 h. Disregard the results of tests in which thebrand does not show progressive and substantially completeconsumption after application to the test specimen. If resultsare disregarded, the procedure shall be repeated using a newtest specimen.8.

48、7 ObservationsDuring and after the burning brand test,observe for deformation from the horizontal plane, location offlaming or glowing combustion, displacement of the testmaterial, flaming drops or particles falling from the deck thatcontinue to burn on the floor and any generated flying brands,and

49、flaming or smoke at the end of 112 h test period. The entiretest shall be recorded with a video or digital recorder to allowreview of the details of performance.9. Accelerated Aging/Weathering9.1 The manufacturer shall have the option to conductartificial or accelerated weathering prior to conducting the firetest. The process used shall evaluate the potential for thefire-test-response characteristics as measured in

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1