1、Revisions and Errata List AISC Steel Design Guide 16, 1stPrinting (Printed Copy) October 15, 2012 The following list represents corrections to the first printing of AISC Design Guide 16, Flush and Extended Multiple-Row Moment End-Plate Connections. Page(s) Item 11 In the left column, Equation 2-11 s
2、hould read: 222,34pimax i pyipwtFQFawt11 In the left column, Equation 2-13 should read: 33.682 0.085pibtad11 In the left column, Equation 2-14 should read: 32,0.85 0.80284pbtppyifibdFtF wFp 11 In the right column, Equation 2-16 should read: 3,min3.682 0.085po bext f ota dPP41 In the left column, sec
3、tion “4.2.2 Four-Bolt Extended Unstiffened Moment End-Plate Connection (Table 4-3)” should be replaced with “4.2.2 Four-Bolt Extended Stiffened Moment End-Plate Connection (Table 4-3).” 47 In the right column under Design Procedure 1, the expression “db= 7/8 in.” should be replaced with “db= 5/8 in.”