1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1309 Marine Shipboard Cable STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZE
2、D FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Marine Shipboard Cable, UL 1309 Third Edition, Dated April 21, 2017 Summary of Topics This new edition of ANSI/UL 1309 is being issued to incorporate the following changes in requirements: 1. Updates to
3、the Standard for Safety for Marine Shipboard Cable, UL 1309 to Coordinate with the Recommended Practice for Marine Cable for Use on Shipboard and Fixed or Floating Facilities, IEEE 1580, Revised Table 4.2 and Table 38.1; 2. Denition of Spacing Between Cable Holes, Revised 29.2; 3. Correction to Test
4、 Temperature in 29.3; 4. Clarication of Reference to Test, Revised 5.4.2.1; 5. Clarication to Constructions Subject to Requirement, Revised 14.1.2, 14.1.3, 14.2.1; and 6. Updated IEC Standard Number, Revised 40.1(j). The revised requirements are substantially in accordance with Proposal(s) on this s
5、ubject dated September 16, 2016 and March 10, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this
6、 Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots,
7、 lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Stan
8、dard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviati
9、on introduced while purchaser is storing an electronic Standard on the purchasers computer system. APRIL 21, 2017 UL 1309 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 21, 2017 UL 1309 tr2 No Text on This PageUL COPYRIGHTED MATERI
10、AL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 21, 2017 1 UL 1309 Standard for Marine Shipboard Cable First Edition July, 1995 Second Edition April, 2011 Third Edition April 21, 2017 This ANSI/UL Standard for Safety consists of the Third edition. The most
11、 recent designation of ANSI/UL 1309 as an American National Standard (ANSI) occurred on April 21, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.
12、 Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights
13、, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 1309-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 21, 2017 MARINE SHIPB
14、OARD CABLE - UL 1309 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .5 3 References.5 CONSTRUCTION 4 Copper Conductors .5 4.1 General .5 4.2 Composition .6 4.3 St
15、randing 6 4.4 Joints .9 4.5 Conductor stress control layer (for cables rated above 2 kV)10 5 Insulation .10 5.1 General 10 5.2 Separator 11 5.3 Thickness of extruded insulation 11 5.4 Properties of insulation .12 6 Insulation Shield .16 7 Binder or Separator 16 8 Braids 16 9 Conductor Identication.1
16、6 10 Shielding 17 11 Individually Shielded Components and Overall Shielding 17 12 Cabling 17 13 Fillers .18 14 Cable Jackets 18 14.1 General .18 14.2 Integral insulation/jacket.20 14.3 Jacket thickness .20 15 Metal Wire Armor (Optional) .21 15.1 General .21 15.2 Aluminum armor .23 15.3 Commercial br
17、onze armor .23 15.4 Copper armor 23 16 Corrugated Aluminum Sheath (Optional).23 17 Paint 24 18 Jacket Over Armor 24 19 Equipment Grounding Conductors 24 20 System Ground.25 PERFORMANCE 21 General25 22 Low Temperature Bend Test .25 23 Low Temperature Impact Test26 24 Sunlight/Weather Resistance Test
18、26 25 Flame Test.26 26 Ease of Stripping Test.27 APRIL 21, 2017 MARINE SHIPBOARD CABLE - UL 1309 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 27 Salt Water Immersion Test.27 28 Oil Compatibility Test28 29 Pulling Through Metal Plates Tes
19、t 28 30 Bending Endurance Test 31 31 Long-Term Insulation Resistance .31 32 Heat Deformation Test 31 33 Heat Shock Test of Jacket .32 34 Tension Set of Jacket 32 35 Hot Oil Resistance 32 36 Vertical-Tray Fire and Smoke-Release Test for Cables with “ST1” Marking 33 MANUFACTURING AND PRODUCTION LINE T
20、ESTS 37 Spark Test (02kVUnshielded Cables)33 38 Dielectric Withstand Test on Finished Cable (0 2.4 kV Cables) .34 39 Insulation Resistance Test on Finished Cable (0 2.4 kV Cables) 35 MARKINGS 40 Cable Identication36 41 Cable Type Designation .37 41.1 General .37 41.2 Specic cable types 38 42 Package
21、 Markings 39 APPENDIX A RECOMMENDED PRACTICE FOR COLOR CODE FOR CONTROL AND SIGNAL CABLES a APRIL 21, 2017 MARINE SHIPBOARD CABLE - UL 1309 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 This Standard species the r
22、equirements for distribution (power) cables, and control and signal cables for installation aboard marine vessels, xed and oating offshore petroleum facilities, and mobile offshore drilling units (MODUs), in accordance with industry installation standards and the regulations of the authorities havin
23、g jurisdiction. The cables are single or multi-conductor, with or without metal armor and/or jacket, and are rated 300V35kV. 1.2 These cables are not intended for use in accordance with the National Electrical Code (NEC), ANSI/NFPA 70. Cables that also meet the requirements for use with the NEC may
24、be additionally marked with the appropriate Type designation from the NEC. 2 Units of Measurement 2.1 In addition to being stated in the inch/pound units that are customary in the USA, each of the requirements in this standard is also stated in units that make the requirement conveniently usable in
25、countries employing the metric system (practical SI). Equivalent although not necessarily exactly identical results are to be expected from applying a requirement in USA or metric terms. Equipment calibrated in metric units is to be used when a requirement is applied in metric terms. 3 References 3.
26、1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. CONSTRUCTION 4 Copper Conductors 4.1 General 4.1.1 All conductors shall be of soft annealed stranded copper wire. The conduct
27、ors may be tinned or alloy coated where necessary to ensure compatibility with primary insulation. Conductor sizes and resistances shall comply, within allowable tolerances, with the Reference Standard for Electrical Wires, Cables, and Flexible Cords, UL 1581. APRIL 21, 2017 MARINE SHIPBOARD CABLE -
28、 UL 1309 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 4.2 Composition 4.2.1 Stranded conductors shall comply with the requirements of the Standard Specication for Soft or Annealed Copper Wire, ASTM B3; the Standard Specication for Concen
29、tric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft, ASTM B8; the Standard Specication for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes, ASTM B33; the Standard Specication for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors,
30、 ASTM B172; the Standard Specication for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors, ASTM B173; the Standard Specication for Bunch-StrandedCopperConductorsforElectricalConductors,ASTMB174;theStandardSpecicationfor Lead-Coated and Lead-Alloy-Coat
31、ed Soft Copper Wire for Electrical Purposes, ASTM B189; the Standard Specication for Compact Round Concentric-Lay-Stranded Copper Conductors, ASTM B496; or the Standard Specication for 19 Wire Combination Unilay-Stranded Copper Conductors for Subsequent Insulation, ASTM B787; as applicable. Metric s
32、izes complying with Conductors of Insulated Cables, IEC 60228 are acceptable. 4.3 Stranding 4.3.1 Except as specied in 4.3.2 4.3.5, the conductors shall be stranded Class B concentric conductors, as specied in the Standard Specication for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard,
33、 or Soft, ASTM B8. See Table 4.1. Table 4.1 Construction and resistance of standard Class B concentric conductors Conductor size Class B stranding Maximum dc resistance (/km at 20C) Area in circular mils AWG or kcmil Number of wires Diameter of strand wire Conductor diameter Uncoated Alloy coated or
34、 tinned mm (mils) mm (in) 640 22 7 0.240 (9.6) 0.7 (0.0288) 55.4 59.4 1 020 20 7 0.310 (12.1) 0.9 (0.0363) 34.6 36.7 1 620 18 7 0.386 (15.2) 1.2 (0.0456) 21.8 23.2 2 580 16 7 0.488 (19.2) 1.5 (0.0576) 13.7 14.6 4 110 14 7 0.615 (24.2) 1.8 (0.0726) 8.62 8.96 6 530 12 7 0.755 (30.5) 2.3 (0.0915) 5.43
35、5.64 10 380 10 7 0.987 (38.5) 2.9 (0.116) 3.41 3.55 16 510 8 7 1.234 (48.6) 3.7 (0.146) 2.14 2.23 20 820 7 7 1.384 (54.5) 4.2 (0.164) 1.70 1.77 26 240 6 7 1.554 (61.2) 4.8 (0.184) 1.35 1.40 33 090 5 7 1.748 (68.8) 5.2 (0.206) 1.07 1.11 41 740 4 7 1.961 (77.2) 5.9 (0.232) 0.848 0.882 52 620 3 7 2.202
36、 (86.7) 6.6 (0.260) 0.673 0.700 66 360 2 7 2.474 (97.4) 7.4 (0.292) 0.534 0.555 83 690 1 19 1.687 (66.4) 8.4 (0.332) 0.423 0.440 105 600 1/0 19 1.892 (74.5) 9.5 (0.373) 0.335 0.349 133 100 2/0 19 2.126 (83.7) 10.6 (0.419) 0.266 0.277 167 800 3/0 19 2.386 (94.0) 11.9 (0.470) 0.211 0.219 211 600 4/0 1
37、9 2.680 (105.5) 13.4 (0.528) 0.167 0.172 250 000 250 37 2.088 (82.2) 14.6 (0.575) 0.142 0.147 300 000 300 37 2.286 (90.0) 16.0 (0.630) 0.118 0.123 APRIL 21, 2017 MARINE SHIPBOARD CABLE - UL 1309 6 Table 4.1 Continued on Next PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DIST
38、RIBUTION WITHOUT PERMISSION FROM UL Table 4.1 Continued Conductor size Class B stranding Maximum dc resistance (/km at 20C) Area in circular mils AWG or kcmil Number of wires Diameter of strand wire Conductor diameter Uncoated Alloy coated or tinned mm (mils) mm (in) 350 000 350 37 2.471 (97.3) 17.3
39、 (0.681) 0.101 0.105 400 000 400 37 2.642 (104.0) 18.5 (0.728) 0.0885 0.0911 500 000 500 37 2.951 (116.2) 20.7 (0.813) 0.0708 0.0729 600 000 600 61 2.520 (99.2) 22.7 (0.893) 0.0590 0.0614 750 000 750 61 2.817 (110.9) 25.3 (0.998) 0.0472 0.0486 1 000 000 1000 61 3.251 (128.0) 29.2 (1.152) 0.0354 0.03
40、64 1 250 000 1250 91 2.977 (117.2) 32.7 (1.289) 0.0283 0.0292 1 500 000 1500 91 3.261 (128.4) 37.0 (1.459) 0.0236 0.0243 2 000 000 2000 127 3.187 (125.5) 41.5 (1.632) 0.0177 0.0182 4.3.2 Class B stranded conductors, compressed to a reduction in diameter of 3 percent maximum of concentric stranded co
41、nductors, shall also be permitted. 4.3.3 Unilay stranded conductors complying with the Standard Specication for 19 Wire Combination Unilay-Stranded Copper Conductors for Subsequent Insulation, ASTM B787 shall also be permitted. 4.3.4 Flexible rope lay stranded conductors may be substituted for conce
42、ntric conductors. Bunch-stranded conductors in sizes 6 AWG and smaller may be substituted for concentric stranded conductor. See Table 4.2. Table 4.2 Construction and resistance of exible stranded conductors Nominal stranding Max. cond diameter Maximum DC resistance Individual wire diameter Ohms per
43、 1000-ft at 25C Ohms per km at 25C AWG or Kcmil Conductor area in circular mils Nominal mm 2 Number of wires inch mm inch mm Bare Coated Bare Coated 22 754 0.38 19 0.0063 0.160 0.0315 0.80 17.19 18.46 56.4 60.6 20 1216 0.62 19 0.0080 0.203 0.0400 1.02 10.83 11.62 35.5 38.1 18 1900 0.96 19 0.0100 0.2
44、54 0.052 1.32 5.91 6.342 19.4 20.8 16 2601 1.32 19 0.0117 0.297 0.062 1.56 4.26 4.527 14.0 14.9 or 16 2426 1.23 19 0.0113 0.287 0.060 1.51 4.63 4.915 15.2 16.1 14 4106 2.08 19 0.0147 0.373 0.076 1.92 2.67 2.835 8.76 9.30 or 14 3831 1.94 19 0.0142 0.361 0.073 1.85 2.93 3.110 9.61 10.2 12 6503 3.29 19
45、 0.0185 0.470 0.095 2.40 1.68 1.784 5.51 5.85 or 12 6088 3.08 19 0.0179 0.455 0.092 2.32 1.84 1.958 6.05 6.42 10 10908 5.53 27 0.0201 0.511 0.128 3.25 1.048 1.101 3.44 3.61 or 10 10319 5.23 37 0.0167 0.424 0.117 2.97 1.045 1.110 3.43 3.64 8 16564 8.4 41 0.0201 0.511 0.147 3.73 0.659 0.692 2.16 2.27
46、or 8 14948 7.6 37 0.0201 0.511 0.147 3.73 0.728 0.765 2.39 2.51 6 26261 13.3 65 0.0201 0.511 0.207 5.26 0.423 0.445 1.39 1.46 or 6 24645 12.5 61 0.0201 0.511 0.207 5.26 0.455 0.478 1.49 1.57 APRIL 21, 2017 MARINE SHIPBOARD CABLE - UL 1309 7 Table 4.2 Continued on Next PageUL COPYRIGHTED MATERIAL NOT
47、 AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Table 4.2 Continued Nominal stranding Max. cond diameter Maximum DC resistance Individual wire diameter Ohms per 1000-ft at 25C Ohms per km at 25C AWG or Kcmil Conductor area in circular mils Nominal mm 2 Number of wires
48、 inch mm inch mm Bare Coated Bare Coated 5 36765 18.6 91 0.0201 0.511 0.244 6.20 0.336 0.353 1.10 1.16 4 41668 21.1 133 0.0177 0.450 0.258 6.55 0.269 0.286 0.88 0.94 or 4 42421 21.5 105 0.0201 0.511 0.264 6.71 0.266 0.279 0.87 0.92 3 53733 27.2 133 0.0201 0.511 0.295 7.49 0.211 0.221 0.69 0.73 or 3
49、50501 25.6 125 0.0201 0.511 0.295 7.37 0.220 0.231 0.72 0.76 2 66140 33.5 133 0.0223 0.566 0.324 8.23 0.183 0.193 0.60 0.63 or 2 60602 30.7 150 0.0201 0.511 0.325 8.23 0.183 0.193 0.60 0.63 or 2 65046 33.0 161 0.0201 0.511 0.325 8.26 0.167 0.175 0.55 0.58 1 84438 42.8 209 0.0201 0.511 0.361 9.17 0.133 0.140 0.44 0.46 or 1 90902 46.1 225 0.0201 0.511 0.390 9.91 0.122 0.128 0.40 0.42 1/0 107467 54.5 266 0.0201 0.511 0.407 10.34 0.1058 0.111 0.35 0.37 or 1/0 111103 56.3 275 0.0201 0.511 0.440 1