1、AECMA STANDARDNORME AECMAAECMA NORMprEN 4612-005Edition P 1March 2005PUBLISHED BY THE EUROPEAN ASSOCIATION OF AEROSPACE INDUSTRIES - STANDARDIZATIONGulledelle 94 - B-1200 Brussels - Tel. + 32 2 775 8110 - Fax. + 32 2 775 8111 - www.aecma-stan.orgICS:Descriptors:ENGLISH VERSIONAerospace seriesCables,
2、 electrical, for general purpose, single and multicore assemblyXLETFE Familyjacketed or screened and jacketedPart 005: Tin plated copperOperating temperatures, between 65 C and 135 CDual extruded wall for openapplications, with jacket without screenUV laser printable Product standardSrie arospatiale
3、Cbles, lectriques, dusage gnral,mono et multiconducteursFamille XLETFEGains ou blinds et gainsPartie 005 : Cuivre tamTempratures de fonctionnementcomprises entre 65 C et 135 CFil double isol pour applications externes,gain non blindMarquable au laser UV Norme de produitLuft- und RaumfahrtEin- und me
4、hradrige elektrische Leitungenfr allgemeine VerwendungXLETFE Familiemit Mantel oder geschirmt und MantelTeil 005: Kupfer verzinntBetriebstemperaturen zwischen 65 C und 135 CDoppelt extrudierte Isolierungfr externe Verwendung,mit Mantel ohne SchirmUV-Laser bedruckbar ProduktnormThis “Aerospace Series
5、“ Prestandard has been drawn up under the responsibility of AECMA-STAN (TheEuropean Association of Aerospace Industries - Standardization). It is published for the needs of theEuropean Aerospace Industry. It has been technically approved by the experts of the concerned Domainfollowing member comment
6、s.Subsequent to the publication of this Prestandard, the technical content shall not be changed to anextent that interchangeability is affected, physically or functionally, without re-identification of the standard.After examination and review by users and formal agreement of AECMA-STAN, it will be
7、submitted as adraft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote andtransformation to full European Standard (EN).The CEN national members have then to implement the EN at national level by giving the EN the statusof a national standard and by withdrawing
8、any national standards conflicting with the EN.Edition approved for publication31 March 2005Comments should be sent within six monthsafter the date of publication toAECMA-STANElectrical DomainCopyright 2005 by AECMA-STANPage 2 prEN 4612-005:2005Foreword This standard was reviewed by the Domain Techn
9、ical Coordinator of AECMA-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA-STANs General Process Manual, this standard has received approval for Publication. Contents Page 1 Scope 3 2 Normative references. 3 3 Definitions and
10、symbols . 3 4 Materials and construction 4 5 Required characteristics. 4 6 Quality assurance. 7 7 Designation 7 8 Identification and marking 7 9 Packaging, labelling and delivery lengths 7 10 Technical specification 7 Page 3 prEN 4612-005:20051 Scope This standard specifies the characteristics of UV
11、 laser printable jacket, tin plated copper conductor, electrical cables,Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer XLETFE family for use in the on-board electrical systems of aircraft at operating temperatures between 65 C and 135 C, operating at voltages not exceeding 600 V r.m.s and fre
12、quencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence. 2 Normative references This European Standard incorporates by d
13、ated or undated reference provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. Dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard onl
14、y when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies. EN 2235, Aerospace series Single and multicore electrical cables, screened and jacketed 1) EN 3475-100*, Aerospace series Cables, electrical, aircraft use Test method
15、s Part 100: General EN 4611-002, Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 002: General 1)EN 4611-004, Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family Part 004: Tin plated copper Op
16、erating temperatures, between 65 C and 135 C Dual extruded wall for open applications UV laser printable Product standard 1)EN 4612-002, Aerospace series Cables, electrical, for general purpose, single and multicore assembly XLETFE Family jacketed or screened and jacketed Part 002: General 1)EN 9133
17、, Aerospace series Quality management systems Qualification Procedure for Aerospace Standard Parts 1)3 Definitions and symbols See EN 3475-100. * And all its parts 1) Published as AECMA Prestandard at the date of publication of this standard Page 4 prEN 4612-005:20054 Materials and construction 4.1
18、Materials These cables shall consist of the following: cores according to EN 4611-004; number of cores 2 to 4. Cores shall be twisted together according to EN 2235. Filler cores shall not be permitted. Outer jacket: XLETFE; it shall be possible to mark the jacket by UV laser printing; minimum thickn
19、ess shall be 0,15 mm. 4.2 Construction See Table 1. Table 1 Multicore without screen, with jacket 2 core 3 core 4 core Max. dia. Mass DC Res. Max. dia. Mass DC Res. Max. dia. Mass DC Res. max. /km max. /km max. /km Size AWG amm kg/km max. mm kg/km max. mm kg/km max. 001 b002 b004 006 010 012 020 030
20、 050 26 24 22 20 18 16 14 12 10 2,40 2,75 2,92 3,40 3,88 4,16 5,34 6,36 7,68 7,02 9,43 11,65 17,66 24,54 31,11 46,86 69,86 106,11 153,5 109,2 61,8 34,2 21,7 15,8 11,2 7,0 4,3 2,56 2,94 3,12 3,64 4,16 4,46 5,73 6,83 8,26 9,82 13,31 16,70 25,44 35,77 45,30 68,65 102,83 156,81 153,5 109,2 61,8 34,2 21,
21、7 15,8 11,2 7,0 4,3 2,82 3,24 3,45 4,03 4,61 4,99 6,36 7,60 9,20 12,65 17,28 21,74 33,35 47,01 59,68 90,44 135,81 207,50 153,5 109,2 61,8 34,2 21,7 15,8 11,2 7,0 4,3 aAWG = Closest American Wire Gauge. bSilver plated copper alloy conductor 4.3 Colour coding of cores and jacket See EN 4611-002. 5 Req
22、uired characteristics According to EN 2235 and EN 3475-100 See Table 2. Page 5 prEN 4612-005:2005Table 2 EN 3475- Test Details 201 Visual examination Applicable 202 Mass Applicable; see Table 1. 203 Dimensions Applicable; see Table 1. 301 Ohmic resistance per unit length Applicable; see Table 1. 302
23、 Voltage proof test Applicable 303 Insulation resistance Applicable (20 2) C, 500 M.km minimum (95 2) C, 1 M.km minimum 304 Surface resistance Not applicable 305 Overload resistance Not applicable 401 Accelerated ageing Applicable Temperature (200 3) C 402 Shrinkage and delamination Applicable Tempe
24、rature (150 5) C Maximum shrinkage at each end of cable: Jacket: 2 mm on size code 001 to 010 3 mm on size code 012 to 050 Cores: 0,80 mm on size 001 to 006 1,00 mm on size 010 to 012 1,20 mm on size 020 to 030 403 Delamination and blocking Applicable Temperature (150 5) C 404 Thermal shock Applicab
25、le Temperatures ( 65 2) C and (260 5) C Maximum shrinkage at each end of cable: Jacket: 2 mm on size code 001 to 010 3 mm on size code 012 to 050 Cores: 0,80 mm on size 001 to 006 1,00 mm on size 010 to 012 1,20 mm on size 020 to 030 405 Bending at ambient temperature Applicable 406 Cold bend test A
26、pplicable Temperature ( 65 2) C 407 Flammability Applicable Methods 1 and 2 Flame applied for 15 s Extinguishing time: 3 s max. 408 Fire resistance Not applicable 409 Air-excluded ageing Not applicable 410 Thermal endurance Not applicable continued Page 6 prEN 4612-005:2005Table 2 (concluded) EN 347
27、5- Test Details 411 Resistance to fluids Applicable Swell not greater than 10 % Scrape not applicable 412 Humidity resistance Applicable Method B Temperature (90 2) C Duration 672 hours 413 Wrap back test Not applicable 414 Differential scanning calorimeter (DSC test) Not applicable 501 Dynamic cut-
28、through Not applicable 502 Notch propagation Not applicable 503 Scrape abrasion Not applicable 504 Torsion Not applicable 505 Tensile test on conductors and strands Not applicable 506 Plating continuity Not applicable 507 Adherence of plating Not applicable 508 Plating thickness Not applicable 509 S
29、olderability Not applicable 510 Tensile strength and elongation of extruded insulation, sheath and jacket material Applicable jacket Eb 75 % minimum TS 34 MPa minimum 511 Cable-to-cable abrasion Not applicable 512 Flexure endurance Not applicable 601 Smoke density Subject to agreement between custom
30、er and supplier 602 Toxicity Subject to agreement between customer and supplier 603 Resistance to wet arc tracking Not applicable 604 Resistance to dry arc propagation Not applicable 605 Wet short circuit test Not applicable 701 Strippability and adherence of insulation to the conductor Not applicab
31、le 702 Screen pushback capability Not applicable 703 Permanence of manufacturers marking Applicable 704 Flexibility Not applicable 705 Contrast measurement Applicable Laser marking K 50 % 706 Laser markability Not applicable Page 7 prEN 4612-005:20056 Quality assurance See EN 9133. 7 Designation EXA
32、MPLE: Description block CABLE, ELECTRICAL Identity block EN4612-005A010P Number of this standard Code letter for number of cores (see EN 4612-002, Table 1) Code for nominal section (see Table 1) Code letter for colour coding of cores (see EN 4612-002) 8 Identification and marking See EN 4612-002. 9 Packaging, labelling and delivery lengths See EN 2235. 10 Technical specification See EN 2235.