ASD-STAN PREN 4641-104-2010 Aerospace series Cables optical 125 mue m diameter cladding Part 104 Semi-loose ruggedized duplex construction 62 5 125 mue m GI fibre nominal 4 95 mm o.pdf

上传人:王申宇 文档编号:453384 上传时间:2018-11-23 格式:PDF 页数:10 大小:140.15KB
下载 相关 举报
ASD-STAN PREN 4641-104-2010 Aerospace series Cables optical 125 mue m diameter cladding Part 104 Semi-loose ruggedized duplex construction 62 5 125 mue m GI fibre nominal 4 95 mm o.pdf_第1页
第1页 / 共10页
ASD-STAN PREN 4641-104-2010 Aerospace series Cables optical 125 mue m diameter cladding Part 104 Semi-loose ruggedized duplex construction 62 5 125 mue m GI fibre nominal 4 95 mm o.pdf_第2页
第2页 / 共10页
ASD-STAN PREN 4641-104-2010 Aerospace series Cables optical 125 mue m diameter cladding Part 104 Semi-loose ruggedized duplex construction 62 5 125 mue m GI fibre nominal 4 95 mm o.pdf_第3页
第3页 / 共10页
ASD-STAN PREN 4641-104-2010 Aerospace series Cables optical 125 mue m diameter cladding Part 104 Semi-loose ruggedized duplex construction 62 5 125 mue m GI fibre nominal 4 95 mm o.pdf_第4页
第4页 / 共10页
ASD-STAN PREN 4641-104-2010 Aerospace series Cables optical 125 mue m diameter cladding Part 104 Semi-loose ruggedized duplex construction 62 5 125 mue m GI fibre nominal 4 95 mm o.pdf_第5页
第5页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、ASD STANDARD NORME ASD ASD NORM prEN 4641-104 Edition P 1 January 2010 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Avenue de Tervuren, 270 - B-1150 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.orgICS: 49.060 Descriptors: ENGLISH VERS

2、ION Aerospace series Cables, optical 125 m diameter cladding Part 104: Semi-loose, ruggedized duplex construction 62,5/125 m GI fibre nominal, 4,95 mm outside diameter Product standard Srie arospatiale Cble, optique, diamtre extrieur de la gaine optique 125 m Partie 104 : Cble structure semi libre,

3、renforce, double voie, fibre gradient dindice 62,5/125 m, diamtre extrieur 4,95 mm Norme de produit Luft- und Raumfahrt Lichtwellenleiterkabel, Claddingdurchmesser 125 m Teil 104: Halbfester Leiteraufbau GI 62,5/125 m, Faser Kabelauendurchmesser 4,95 mm Produktnorm This “Aerospace Series“ Prestandar

4、d has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following member comments

5、. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-STAN, it will be

6、submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard and by withdraw

7、ing any national standards conflicting with the EN. Edition approved for publication 31 January 2010 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2010 by ASD-STAN prEN 4641-104:2010 (E) 2 Contents Page Foreword2 1 Scope 3 2 Normative

8、 references 3 3 Terms and definitions .3 4 Required characteristics.3 5 Cable construction 4 6 Materials .4 7 Test methods and performances .5 8 Tooling 9 9 Quality assurance9 10 Designation, marking and colours.9 11 Delivery conditions. 10 12 Storage. 10 Foreword This standard was reviewed by the D

9、omain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 4641-104:2010 (E) 3 1 Scope This product standard specifie

10、s the general characteristics, conditions for qualification, acceptance and quality assurance for a fibre optic cable with two 62,5/125 m graded index fibre cores, 4,95 mm nominal outside diameter and of semi loose construction. The basic construction is a pair of the cables defined in EN 4641-102 w

11、ith added sheaths for ruggedized usages. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendm

12、ents) applies. EN 2424, Aerospace series Marking of aerospace products EN 3745-100 (all parts), Aerospace series Fibres and cables, optical, aircraft use Test methods Part 100: General EN 3838, Aerospace series Requirements and tests on user-applied markings on aircraft electrical cables 1)EN 4641-0

13、01, Aerospace series Cables, optical 125 m diameter cladding Part 001: Technical specification EN 4641-102, Aerospace series Cables, optical 125 m diameter cladding Part 102: Semi-loose 62,5/125 m GI fibre nominal 1,8 mm outside diameter Product standard 1)EN 9133, Aerospace series Quality managemen

14、t systems Qualification procedure for aerospace standard parts TR 4647, Aerospace series Termination procedure for EN 4639 optical contact 2)3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 3745-100 apply. 4 Required characteristics The characteristics

15、 of the cables, tested according to the methods described hereafter shall comply with the values defined in this product standard. 1) Published as ASD-STAN Prestandard at the date of publication of this standard. 2) Published as ASD-STAN Technical Report at the date of publication of this standard.

16、prEN 4641-104:2010 (E) 4 5 Cable construction See Figure 1 and Table 1. TWO TYPE 1 CLASS 1 FIBER OPTIC CABLESBARRIER:PTFE TAPEOVERALL JACKET: FEPGREEN TRACERNATURALFILLER: 2 PLACES2 - EN 4641-102 Fiber Optic CablesOverall jacket - ExtrudedFluoropolymerGreen Tracer or LaserIDFillers - 2 PlacesPTFE Ba

17、rrier TapeKey 1 Filler 2 places 2 Overall jacket Extruded fluoropolymer 3 Green tracer or laser ID 4 EN 4641-102 fibre optic cables 5 PTFE barrier tape Figure 1 Table 1 Property Value EN 4641-102 Fibre optic cable (1,80 1,2) mm Finished cable diameter 4,95 mm Cable mass 26,5 g/m Operating temperatur

18、e 65 C to 150 C Attenuation at 850 nm (20 C) 4 dB/km Attenuation at 1 300 nm (20C) 2 dB/km Numerical aperture 0,275 0,015 Minimum bend radius (20 C) Installation: 50 mm (10 outside diameter) Long term: 50 mm (10 outside diameter) Storage: 100 mm (20 cable outside diameter) 6 Materials See Table 2. 2

19、15 34 prEN 4641-104:2010 (E) 5 Table 2 Element Material 2 - Fibre cable components EN 4641-102 Fibre optic cable 2 fillers PTFE Barrier tape PTFE Outer jacket Extruded fluoropolymer 7 Test methods and performances 7.1 Tests in accordance with EN 3745-100 7.1.1 Optical fibre tests In accordance with

20、EN 4641-102. 7.1.2 Fibre optic component cable tests In accordance with EN 4641-102. 7.1.3 Ruggedized fibre optic cable Tests in accordance with Table 3. Table 3 Ruggedized fibre optic cable test methods Designation of the test Test method EN 3745- Test conditions and results Visual examination 201

21、The outer jacket shall have the correct identification as specified in this standard. The coating shall be continuous and free of visible defects such as lumps, abrasions, cracks, splits or blisters. Sample length: 3 m Outer jacket outside diameter 203 (4,95 0,25) mm Outer jacket wall thickness 203

22、Minimum wall 0,20 mm Cable longitudinal dimensional stability 205 The change in longitudinal dimensions between A and B shall not exceed the maximum value of 5 mm Number of samples: 3 Sample Length: (3,5 0,03) m Test Method EN 3745-402 25 cycles Fibre attenuation 301 Method D Maximum attenuation 4 d

23、B/km at 850 nm, 2 dB/km at 1 300 nm at 20 C Minimum sample length: 100 m Cable immunity to ambient light coupling 305 Not applicable. This is an EN 4641-102 component test. Cable accelerated ageing 401 Not applicable if jacket materials are the same. This is an EN 4641-102 component test. continued

24、prEN 4641-104:2010 (E) 6 Table 3 Ruggedized fibre optic cable test methods (continued) Designation of the test Test method EN 3745- Test conditions and results Variation of attenuation during temperature cycling 306 Visual examination in accordance with EN 3745-201. Maximum variation of attenuation:

25、 a 0,25 dB at 850 nm and 1 300 nm. Test method EN 3745-402 10 cycles High temperature: 150 C Low temperature: 65 C Duration at extreme temperatures: 30 minutes Rate of change: 5 C per minute Number of samples: 3 Sample length: 5 m Thermal shock 404 Visual examination in accordance with EN 3745-201.

26、Maximum permissible variation in attenuation during test sequence and after 24 h: 0,25 dB at 850 nm and 1 300 nm. High temperature: 150 C Low temperature: 65 C Duration at extreme temperatures: 30 minutes Number of samples: 3 Sample Length: 10 m Number of temperature cycles: 10 Cold bend 406 Maximum

27、 permissible variation in attenuation: 0,25 dB at 850 nm and 1 300 nm. Visual examination in accordance with EN 3745-201. 1 hour soak at: 65 C Mandrel size: (50 1) mm Mandrel wraps: 10 Number of samples: 1 Sample Length: 10 m Flammability 407 No flaming particles shall fall from the sample during th

28、e test and the tissue paper shall not be ignited. Period of flame application: 30 seconds Maximum burn length: 75 mm Self extinguish after 5 seconds Number of samples: 3 Sample length: (1 0,05) m Thermal life 410 Not applicable if jacket materials are the same. This is an EN 4641-102 component test.

29、 Resistance to fluids 411 Method 2 Not applicable if jacket materials are the same. This is an EN 4641-102 component test. Humidity resistance 412 Not applicable if jacket materials are the same. This is an EN 4641-102 component test. Scrape abrasion 503 Maximum variation in attenuation: 0,25 dB at

30、850 nm and 1 300 nm. Visual examination in accordance with EN 3745-201. Number of samples: 3 Sample length: 3 m Test at ambient temperature: Load: 7 N Number of cycles: 500 Test at high temperature: 150 C Load: 22 N Number of cycles: 500 continued prEN 4641-104:2010 (E) 7 Table 3 Ruggedized fibre op

31、tic cable test methods (continued) Test Test method EN 3745- Test conditions and results Tensile strength 505 Maximum variation in attenuation: 0,25 dB at 850 nm and 1 300 nm. Mandrel diameter: 50 mm Tensile Strength: 50 N Pulling speed: (50 10) mm/min Number of samples: 3 Sample length: 5 m Impact

32、506 Maximum variation in attenuation: 0,1 dB at 850 nm and 1 300 nm. Test at ambient temperature: 20 C Load to be applied: 15 N Radius intermediate piece: 12 mm Drop height: 150 mm Number of impacts: 10 Number of samples: 3 Sample length: 700 mm Cut-through 507 Visual examination in accordance with

33、EN 3745-201. Monitor attenuation to determine fibre breakage of the sample during testing at 20 C and 150 C. Test at ambient temperature (20 C): Load: 330 N Test at high temperature (150 C): 85 N Load: 85 N Duration of load application: 1 min Number of samples: 3 Sample length: 3 m Torsion 508 Added

34、 to test criterion: No cracking or splitting of cable jacket Maximum variation of attenuation: For one cycle: 0,1 dB For 1 000 cycles: 0,10 dB Number of samples: 3 Sample length: 3 m Load to be applied: 150 N Number of cycles: 1,000 Distance between the rotating grip and the fixed grip: (0,25 0,01)

35、m Bend 510 Method B Maximum variation of attenuation: 0,25 dB at 850 nm and 1 300 nm. Residual attenuation after removing the specimen from the test equipment: 0,1 dB. Visual examination in accordance with EN 3745-201. Mandrel diameter: (50 1) mm Number of turns: 10 Number of samples: 1 Sample lengt

36、h: 10 m Cable to cable abrasion 511 Not applicable if jacket materials are the same. This is an EN 4641-102 component test. continued prEN 4641-104:2010 (E) 8 Table 3 Ruggedized fibre optic cable test methods (continued) Designation of the test Test method EN 3745- Test conditions and results Flexur

37、e endurance 512 Examination of test specimen for damage in accordance with EN 3745-201 (visual examination). Maximum permissible variation of attenuation: 0,25 dB at 850 nm and 1 300 nm. Number of samples: 3 Length of the sample: 5 m Load to be applied: 11,5 N Diameter of mandrel: 28 mm Number of cy

38、cles: 100,000 Crush resistance 513 Maximum variation of attenuation: 0,1 dB No cracking or splitting of cable jacket Load: 445 N Area of load: 100 mm2 Number of samples: 3 Sample length: 3 m Extreme cable bend 516 Examination of test specimen for damage in accordance with EN 3745-201 (visual examina

39、tion). No fibre breakage. Maximum permissible variation of attenuation: 0,50 dB Load to be applied : 127 N Maximum edge radius: 127 m Number of cycles: One bend in each direction Number of samples : 3 Length of the sample: 3 m Cable Clamping 517 Typical requirements: Maximum transmittance change: 0,

40、05 dB Mandrel diameter: (13 1) mm Cable tie spacing: 90 mm Number of cable ties applied: 6 Cable tie tension setting: #1 Number of samples: 3 Sample length: 4 m Smoke density 601 Specific optical smoke density (average) Ds 200 within 4 minutes test duration under both the flaming and non-flaming con

41、ditions. Value must be measured at the end of the test. Toxicity 602 HF 300 ppm HCL 150 ppm HCN 150 ppm SO2 100 ppm H2S 100 ppm NO 100 ppm NO2 100 ppm CO 1 000 ppm Nuclear radiation 603 Not applicable. continued prEN 4641-104:2010 (E) 9 Table 3 Ruggedized fibre optic cable test methods (concluded) D

42、esignation of the test Test method EN 3745- Test conditions and results Cable stripping 701 Not applicable. Durability of manufacturers identity markings 703 Not applicable Marker tape under jacket. Contrast measurement 705 Not applicable Marker tape under jacket. Durability of user identification m

43、arkings 706 EN 3838 Except sub-clause 6.8 Not applicable. General test conditions: The tests shall be performed with the following launch condition: 70/70 % 8 Tooling See TR 4647 termination processes. 9 Quality assurance See EN 9133. 10 Designation, marking and colours 10.1 Designation EXAMPLE Desc

44、ription block CABLE FIBRE OPTIC Identity block EN4641-104 Number of the basic standard Product standard 10.2 Marking The marking shall comprise of the cable reference, the manufacturer code and the last two digits of the year of manufacture shall conform to EN 2424. The marking may be done wholly or

45、 partially in code by agreement with the user. The cable shall use marker tape under the outer jacket or the outer jacket shall be marked with a UV laser. Hot stamping is forbidden. 10.3 Colours The colour of the outer jacket will be light purple or as specified by customer. prEN 4641-104:2010 (E) 1

46、0 11 Delivery conditions 11.1 Packaging See EN 4641-001. 11.2 Labelling See EN 4641-001. 11.3 Delivery lengths The minimum delivery length of a fibre or cable is by agreement between customer and supplier. 12 Storage Fibre optic cables shall be stored as described hereunder: Humidity: 90 % Temperatures: 65 C to 85 C CAUTION Let cable warm up prior to handling if fibre optic cable has been stored for prolonged periods of time below 0 C Tensile strength on cable 30 N.

展开阅读全文
相关资源
  • ASD-STAN PREN 4022-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead Welded (Edition P1)《航空航天系列 钛合金制830管接头 90焊接穿壁弯头 第P1版[替代 ASD-STAN.pdfASD-STAN PREN 4022-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead Welded (Edition P1)《航空航天系列 钛合金制830管接头 90焊接穿壁弯头 第P1版[替代 ASD-STAN.pdf
  • ASD-STAN PREN 4021-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead (Edition P1)《航空航天系列 钛合金制830管接头 90穿壁弯头 第P1版[替代 ASD-STAN PREN 325.pdfASD-STAN PREN 4021-1994 Aerospace Series Pipe Coupling 8 Degrees 30 in Titanium Alloy Elbows 90 Degrees Bulkhead (Edition P1)《航空航天系列 钛合金制830管接头 90穿壁弯头 第P1版[替代 ASD-STAN PREN 325.pdf
  • ASD-STAN PREN 4018-2007 Aerospace series Pipe coupling 8 degree 30 in titanium alloy Elbows 90 degree with thrust wire nut (Edition P2)《航空航天系列 钛合金制830管接头 旋转螺母、带止推金属丝帽的90弯头 第P2版.pdfASD-STAN PREN 4018-2007 Aerospace series Pipe coupling 8 degree 30 in titanium alloy Elbows 90 degree with thrust wire nut (Edition P2)《航空航天系列 钛合金制830管接头 旋转螺母、带止推金属丝帽的90弯头 第P2版.pdf
  • ASD-STAN PREN 3256-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 45 Degree Swivel Nut Welded (Edition P 2 )《航空航天系列 钛合金制830管接头 旋转螺母、焊接式45弯头 第P2版[替代为 AS.pdfASD-STAN PREN 3256-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 45 Degree Swivel Nut Welded (Edition P 2 )《航空航天系列 钛合金制830管接头 旋转螺母、焊接式45弯头 第P2版[替代为 AS.pdf
  • ASD-STAN PREN 3254-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead Welded (Edition P 2)《航空航天系列 钛合金制830管接头 焊接式穿壁90弯头 第P2版[替代为 ASD-STAN.pdfASD-STAN PREN 3254-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead Welded (Edition P 2)《航空航天系列 钛合金制830管接头 焊接式穿壁90弯头 第P2版[替代为 ASD-STAN.pdf
  • ASD-STAN PREN 3253-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead (Edition P 2 )《航空航天系列 钛合金制830管接头 穿壁90弯头 第P2版[替代为 ASD-STAN PREN 402.pdfASD-STAN PREN 3253-1994 Aerospace Series Pipe Coupling 8 Degree 30 in Titanium Alloy Elbow 90 Degree Bulkhead (Edition P 2 )《航空航天系列 钛合金制830管接头 穿壁90弯头 第P2版[替代为 ASD-STAN PREN 402.pdf
  • ASD-STAN TR AMS2750-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdfASD-STAN TR AMS2750-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdf
  • ASD-STAN TR AMS2750 FRENCH-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdfASD-STAN TR AMS2750 FRENCH-2009 《航空航天系列 航空航天材料规范 高温测定法》.pdf
  • ASD-STAN TR 9536-2008 Aerospace series Declarable Substances Recommended Practice《航空航天系列 需申报物质 建议做法》.pdfASD-STAN TR 9536-2008 Aerospace series Declarable Substances Recommended Practice《航空航天系列 需申报物质 建议做法》.pdf
  • ASD-STAN TR 9535-2008 Aerospace series Substance declaration (Edition 1)《航空航天系列 物质声明 第1版》.pdfASD-STAN TR 9535-2008 Aerospace series Substance declaration (Edition 1)《航空航天系列 物质声明 第1版》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASD

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1