ASTM C390-2003 Standard Practice for Sampling and Acceptance of Thermal Insulation Lots《隔热材料的抽样和验收的标准实施规程》.pdf

上传人:boatfragile160 文档编号:466456 上传时间:2018-11-27 格式:PDF 页数:3 大小:29.83KB
下载 相关 举报
ASTM C390-2003 Standard Practice for Sampling and Acceptance of Thermal Insulation Lots《隔热材料的抽样和验收的标准实施规程》.pdf_第1页
第1页 / 共3页
ASTM C390-2003 Standard Practice for Sampling and Acceptance of Thermal Insulation Lots《隔热材料的抽样和验收的标准实施规程》.pdf_第2页
第2页 / 共3页
ASTM C390-2003 Standard Practice for Sampling and Acceptance of Thermal Insulation Lots《隔热材料的抽样和验收的标准实施规程》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: C 390 03Standard Practice forSampling and Acceptance of Thermal Insulation Lots1This standard is issued under the fixed designation C 390; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu

2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This standard provides criteria for establishing theacc

3、eptability of lots of shipments of preformed board, pre-formed block and pipe, and batts and blanket thermal insula-tion based on sampling and inspection.1.2 This standard is intended for use in conjunction withappropriate ASTM material specifications that classify anddescribe the specific physical

4、requirements for the product interms of qualification requirements and inspection require-ments. Determination of nonconformity shall be based on thetolerances for individual sample test values prescribed in thematerial specification.1.3 This standard may require inspection substantially dif-ferent

5、from that performed in the normal course of production.If the purchaser requires sampling and acceptance inspection inaccordance with this practice, he shall so specify in the order orcontract.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. I

6、t is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 168 Terminology Relating to Thermal Insulation22.2 U.S. Military Standard:MIL-

7、STD-105E Sampling Procedures and Tables for In-spection by Attributes33. Terminology3.1 Definitions:3.1.1 acceptable quality level (AQL)when a continuousseries of lots is considered, the quality level which for purposesof sampling inspection is the limit of a satisfactory processaverage. The listed

8、AQL (AQL=10%) is the maximum percentdefective level accepted 95% of the time by the sampling plan.3.1.2 acceptance numberthe maximum number of thenonconformities or nonconforming units in the sample that willpermit acceptance of the inspected lot or batch.3.1.3 inspectionthe process of measuring, ex

9、amining,testing, gaging, or otherwise comparing the unit with theapplicable requirements.3.1.4 inspection lota collection of units of product fromwhich a sample is drawn and inspected to determine conform-ance with the acceptability criteria.3.1.4.1 DiscussionAn inspection lot may differ from a lotd

10、efined for other purposes.3.1.5 inspection, normalinspection that is used in accor-dance with an acceptance sampling scheme when a process isconsidered to be operating at, or slightly better than, itsacceptable quality level.3.1.6 inspection, tighteneda feature of a sampling schemeusing stricter acc

11、eptance criteria than those used in normalinspection. Tightened inspection is used in some samplingschemes as a protective measure to increase the probability ofrejecting lots when experience shows the level of submittedquality has deteriorated significantly.3.1.6.1 DiscussionIt is expected that the

12、 higher rate ofrejections inherent with tightened inspection will lead thesupplier to improve the quality of the submitted product. Thecriteria for determining when quality has deteriorated signifi-cantly must be defined in objective terms for any givensampling scheme.3.1.7 lot (batch)a definite qua

13、ntity of some productmanufactured under conditions of production that are consid-ered uniform.3.1.8 lot sizethe number of units in a lot or inspection lot.3.1.9 nonconforming unita unit of product or servicecontaining at least one nonconformity.3.1.10 nonconformitya departure of a quality characteri

14、s-tic from its intended level or state that occurs with a severitysufficient to cause the product or service not to meet aspecification requirement.1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.31 on Chemical

15、andPhysical Properties.Current edition approved April 10, 2003. Published May 2003. Originallyapproved in 1957. Last previous edition approved 2002 as C 390 02.2Annual Book of ASTM Standards, Vol 04.06.3Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadel

16、phia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.11 samplea group of units, portion of material, orobservations taken from the inspection lot that serves toprovide information that may be used as a

17、 basis for making adecision concerning the lot being inspected.3.1.12 sample sizethe number of units in a sample or thenumber of observations in a sample.3.1.13 unitan object on which a measurement or obser-vation may be made.3.2 Descriptions of Terms Specific to This Standard:3.2.1 lotan inspection

18、 lot as defined in 3.1.4.3.2.2 shipping packagethe smallest discrete package ofthermal insulation for purposes of shipping. Typically, ashipping package is one roll, bundle, bag, or carton of thermalinsulation.3.2.3 unita shipping package as described in 3.2.2.4. Significance and Use4.1 The sampling

19、 and inspection prescribed in this standardafford the purchaser a practical level of quality assurance onincoming material. They are based on cost/risk relationshipsconsidered typical for preformed thermal insulations offeredfor general use. In all cases, the purchaser should review thisstandard and

20、 determine its suitability in terms of his specificneeds.4.2 This procedure is intended primarily for the inspectionof a continuing stream of lots, and there is not a highprobability of rejecting occasional off lots. Consumer protec-tion is based on economic pressure on the producer, throughgreater

21、risk of lot rejection, to maintain the process average at90 % conformance or better. Operating characteristic curvesfor the sampling plans employed can be found in MIL-STD-105E, Table X-C through Table X-F.4.3 It is not the intent of this procedure to estimate lotquality, control the quality of prod

22、uction, relieve the supplier ofresponsibility for the quality of material offered, or determinethe disposition of material found to be defective after receipt bythe purchaser.5. Classification of Requirements5.1 ASTM material specifications shall classify physicalrequirements in two categories:5.1.1

23、 Qualification RequirementsThose requirementswhich establish the general suitability of the product but are notjudged necessary, or practical, for routine inspection. Theserequirements usually relate to the inherent properties of thematerial, involve high inspection costs, require long-term tests,or

24、 are controlled indirectly by other requirements.5.1.2 Inspection RequirementsThose requirements whichcan and should be monitored on a routine basis. Theserequirements are characterized by a high benefit/cost ratio.They may include visual and dimensional requirements, re-quirements for properties wi

25、th potentially high variability, orrequirements providing indirect control of performance char-acteristics.6. Acceptance for Qualification Requirements6.1 The suppliers certificate of compliance or a thirdpartys certificate of compliance shall be sufficient basis foracceptance of the lot for qualifi

26、cation requirements.6.1.1 The certificate shall state that compliance to thequalification requirements has been verified by actual inspec-tion of material manufactured within the past three years usingthe same basic ingredients and manufacturing process as thematerial offered.6.1.2 The supplier shal

27、l furnish an inspection report uponrequest.7. Acceptance for Inspection Requirements7.1 The acceptance of a lot for inspection requirements shallbe based on the sampling plans and acceptance criteriaprescribed in Table 1 (preformed board, and preformed blockand pipe) and Table 2 (batts and blanket).

28、 Single Inspection andAQL = 10 % shall be used.7.2 Sampling and inspection shall be carried out as de-scribed in Section 8. Test sample shall be randomly selectedfrom the lot.7.3 For preformed board, and preformed block and pipe lotsof 150 units or less, or batts and blanket lots of 16 146ft2(1500 m

29、2) or less, not subject to tightened inspection, thesuppliers certificate of compliance or a third partys certificateof compliance shall be sufficient basis for acceptance of the lotfor inspection requirements.7.3.1 The certificate shall state that compliance to inspec-tion requirements has been ver

30、ified by actual inspection ofmaterial of the same type, class, form, size, and thicknessmanufactured within the same production period as the mate-rial offered.7.3.2 The supplier shall furnish pertinent inspection recordsupon request.TABLE 1 Sampling Plan and Acceptance Criteria for Inspection Requi

31、rementsA(Preformed Board, and Preformed Block and Pipe)Lot Size (Shipping Units)Normal Inspection Tightened InspectionSample Size(Shipping Packages)Acceptance Number,Maximum Number ofNonconforming UnitsSample Size(Shipping Packages)AcceptanceNumber,Maximum NumberofNonconformingUnits150 or less see 7

32、.3 see 7.3 5 1151 to 1200 5 1 8 11201 to 35 000 8 2 8 135 000 and over 13 3 13 2AThe plan for normal inspection of lot sizes of 151 units and over, and the entire plan for tightened inspection are taken from MIL-STD-105E, using Special InspectionLevel S-2, AQL = 10 %.C3900328. Procedure for Sampling

33、 and Inspection8.1 Establish the grouping of product to be considered thelot and determine the lot size:8.1.1 Unless otherwise specified in the material specifica-tion, order, or contract, the lot shall consist of all thermalinsulation of one type, class, form, size, and thickness pro-duced under th

34、e same conditions and procured at the sametime.8.1.2 The lot size shall be equal to the number of shippingpackages in the lot.8.2 Determine the required sample size from Table 1,expressed in terms of shipping units:8.2.1 Use normal inspection at the start of inspection and forany single lot.8.2.2 Sh

35、ift from normal to tightened inspection when two offive consecutive lots have been rejected.8.2.3 Shift from tightened to normal inspection after fiveconsecutive lots have been accepted.8.2.4 In the event that ten consecutive lots remain ontightened inspection, discontinue inspection under this stan

36、-dard pending action to improve the quality of submittedproduct.8.3 Select the sample from the lot:8.3.1 The sample shall consist of the number of shippingpackages determined as the sample size in 8.2.8.3.2 Select individual shipping packages from the entire lotat random and without regard to expect

37、ed quality. Whenappropriate, select units from different sublots identified bysome rational criterion such as shipment or production group-ings.8.4 Perform the inspection called for in the ASTM materialspecification:8.4.1 From each shipping package in the sample, drawsufficient insulation material t

38、o perform the complete inspec-tion. This may require a full shipping package or a portionthereof, as one or more pieces cut from a roll or one or moreboards or sections from a carton. Select the material at randomand without regard to quality.8.4.2 Inspect the insulation material drawn from each shi

39、p-ping package in the sample. Perform the number of determi-nations prescribed in the product specification or specified testmethods.8.5 Establish the number of nonconforming units in thesample:8.5.1 Compare the inspection results on the material drawnfrom each shipping unit to the requirements of t

40、he materialspecification.8.5.2 Classify the shipping unit as a nonconforming unit ifthe inspection results show one or more nonconformities to thematerial specification.8.6 Determine the acceptability of the lot:8.6.1 If the number of nonconforming units is equal to orless than the appropriate accep

41、tance number in Table 1, acceptthe lot.8.6.2 If the number of nonconforming units is greater thanthe acceptance number, reject the lot.9. Keywords9.1 batts; blanket; block; board; pipe; preformed; samplingand acceptance; thermal insulationASTM International takes no position respecting the validity

42、of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject t

43、o revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters.

44、 Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is

45、copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceast

46、m.org (e-mail); or through the ASTM website(www.astm.org).TABLE 2 Sampling Plan and Acceptance Criteria for Inspection RequirementsA(Batts and Blankets)Lot Size (m2)BNormal Inspection Tightened InspectionSample Size(Shipping Packages)Acceptance Number,Maximum Number ofNonconforming UnitsSample Size(

47、Shipping Packages)Acceptance Number,Maximum Number ofNonconforming Units1500 or less see 7.3 see 7.3 5 11501 to 2500 51812501 to 5000 82815001 to 9000 13 3 13 29001 to 15 000 20 5 20 315 001 to 28 000 32 7 32 528 001 and over 50 10 50 8AThe plan for normal inspection of lot sizes of 1500 m2and over,

48、 and the entire plan for tightened inspection are taken from MILSTD105E, using Normal InspectionLevel II, AQL = 10 % and sample size based on 1080 ft2(100 m2) per unit.BLot sizes for ft2are 16 146 or less, 16 417 to 26 911, 26 912 to 53 821, 53 822 to 96 878, 96 879 to 161 460, 161 461 to 301 399, and 301 400 and over.C390033