ASTM C623-1992(2010) Standard Test Method for Youngs Modulus Shear Modulus and Poissons Ratio for Glass and Glass-Ceramics by Resonance《用共振现象对玻璃和玻璃陶瓷材料的杨氏模量 剪切模量及泊松比的标准试验方法》.pdf

上传人:proposalcash356 文档编号:507811 上传时间:2018-12-01 格式:PDF 页数:7 大小:132.73KB
下载 相关 举报
ASTM C623-1992(2010) Standard Test Method for Youngs Modulus Shear Modulus and Poissons Ratio for Glass and Glass-Ceramics by Resonance《用共振现象对玻璃和玻璃陶瓷材料的杨氏模量 剪切模量及泊松比的标准试验方法》.pdf_第1页
第1页 / 共7页
ASTM C623-1992(2010) Standard Test Method for Youngs Modulus Shear Modulus and Poissons Ratio for Glass and Glass-Ceramics by Resonance《用共振现象对玻璃和玻璃陶瓷材料的杨氏模量 剪切模量及泊松比的标准试验方法》.pdf_第2页
第2页 / 共7页
ASTM C623-1992(2010) Standard Test Method for Youngs Modulus Shear Modulus and Poissons Ratio for Glass and Glass-Ceramics by Resonance《用共振现象对玻璃和玻璃陶瓷材料的杨氏模量 剪切模量及泊松比的标准试验方法》.pdf_第3页
第3页 / 共7页
ASTM C623-1992(2010) Standard Test Method for Youngs Modulus Shear Modulus and Poissons Ratio for Glass and Glass-Ceramics by Resonance《用共振现象对玻璃和玻璃陶瓷材料的杨氏模量 剪切模量及泊松比的标准试验方法》.pdf_第4页
第4页 / 共7页
ASTM C623-1992(2010) Standard Test Method for Youngs Modulus Shear Modulus and Poissons Ratio for Glass and Glass-Ceramics by Resonance《用共振现象对玻璃和玻璃陶瓷材料的杨氏模量 剪切模量及泊松比的标准试验方法》.pdf_第5页
第5页 / 共7页
亲,该文档总共7页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: C623 92 (Reapproved 2010)Standard Test Method forYoungs Modulus, Shear Modulus, and Poissons Ratio forGlass and Glass-Ceramics by Resonance1This standard is issued under the fixed designation C623; the number immediately following the designation indicates the year oforiginal adoption o

2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the elasticproperties of glass an

3、d glass-ceramic materials. Specimens ofthese materials possess specific mechanical resonance frequen-cies which are defined by the elastic moduli, density, andgeometry of the test specimen. Therefore the elastic propertiesof a material can be computed if the geometry, density, andmechanical resonanc

4、e frequencies of a suitable test specimenof that material can be measured. Youngs modulus is deter-mined using the resonance frequency in the flexural mode ofvibration. The shear modulus, or modulus of rigidity, is foundusing torsional resonance vibrations. Youngs modulus andshear modulus are used t

5、o compute Poissons ratio, the factorof lateral contraction.1.2 All glass and glass-ceramic materials that are elastic,homogeneous, and isotropic may be tested by this test method.2The test method is not satisfactory for specimens that havecracks or voids that represent inhomogeneities in the materia

6、l;neither is it satisfactory when these materials cannot beprepared in a suitable geometry.NOTE 1Elastic here means that an application of stress within theelastic limit of that material making up the body being stressed will causean instantaneous and uniform deformation, which will cease upon remov

7、alof the stress, with the body returning instantly to its original size and shapewithout an energy loss. Glass and glass-ceramic materials conform to thisdefinition well enough that this test is meaningful.NOTE 2Isotropic means that the elastic properties are the same in alldirections in the materia

8、l. Glass is isotropic and glass-ceramics are usuallyso on a macroscopic scale, because of random distribution and orientationof crystallites.1.3 A cryogenic cabinet and high-temperature furnace aredescribed for measuring the elastic moduli as a function oftemperature from 195C to 1200C.1.4 Modificat

9、ion of the test for use in quality control ispossible. A range of acceptable resonance frequencies isdetermined for a piece with a particular geometry and density.Any specimen with a frequency response falling outside thisfrequency range is rejected. The actual modulus of each pieceneed not be deter

10、mined as long as the limits of the selectedfrequency range are known to include the resonance frequencythat the piece must possess if its geometry and density arewithin specified tolerances.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in

11、 thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2

12、. Summary of Test Method2.1 This test method measures the resonance frequencies oftest bars of suitable geometry by exciting them at continuouslyvariable frequencies. Mechanical excitation of the specimen isprovided through use of a transducer that transforms an initialelectrical signal into a mecha

13、nical vibration. Another trans-ducer senses the resulting mechanical vibrations of the speci-men and transforms them into an electrical signal that can bedisplayed on the screen of an oscilloscope to detect resonance.The reasonance frequencies, the dimensions, and the mass ofthe specimen are used to

14、 calculate Youngs modulus and theshear modulus.3. Significance and Use3.1 This test system has advantages in certain respects overthe use of static loading systems in the measurement of glassand glass-ceramics:3.1.1 Only minute stresses are applied to the specimen, thusminimizing the possibility of

15、fracture.3.1.2 The period of time during which stress is applied andremoved is of the order of hundreds of microseconds, makingit feasible to perform measurements at temperatures wheredelayed elastic and creep effects proceed on a much-shortenedtime scale, as in the transformation range of glass, fo

16、r instance.1This test method is under the jurisdiction of ASTM Committee C14 on Glassand Glass Products and is the direct responsibility of Subcommittee C14.04 onPhysical and Mechanical Properties.Current edition approved April 1, 2010. Published May 2010. Originallyapproved in 1969. Last previous e

17、dition approved in 2005 as C623 92 (2005).DOI: 10.1520/C0623-92R10.2Spinner, S., and Tefft, W. E., “A Method for Determining MechanicalResonance Frequencies and for Calculating Elastic Moduli from These Frequen-cies,” Proceedings, ASTM, 1961, pp. 12211238.1Copyright ASTM International, 100 Barr Harb

18、or Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2 The test is suitable for detecting whether a materialmeets specifications, if cognizance is given to one importantfact: glass and glass-ceramic materials are sensitive to thermalhistory. Therefore the thermal history of a tes

19、t specimen mustbe known before the moduli can be considered in terms ofspecified values. Material specifications should include aspecific thermal treatment for all test specimens.4. Apparatus4.1 The test apparatus is shown in Fig. 1. It consists of avariable-frequency audio oscillator, used to gener

20、ate a sinusoi-dal voltage, and a power amplifier and suitable transducer toconvert the electrical signal to a mechanical driving vibration.A frequency meter monitors the audio oscillator output toprovide an accurate frequency determination. A suitablesuspension-coupling system cradles the test speci

21、men, andanother transducer acts to detect mechanical resonance in thespecimen and to convert it into an electrical signal which ispassed through an amplifier and displayed on the vertical platesof an oscilloscope. If a Lissajous figure is desired, the output ofthe oscillator is also coupled to the h

22、orizontal plates of theoscilloscope. If temperature-dependent data are desired, asuitable furnace or cryogenic chamber is used. Details of theequipment are as follows:4.2 Audio Oscillator, having a continuously variable fre-quency output from about 100 Hz to at least 20 kHz. Frequencydrift shall not

23、 exceed 1 Hz/min for any given setting.4.3 Audio Amplifier, having a power output sufficient toensure that the type of transducer used can excite any specimenthe mass of which falls within a specified range.4.4 TransducersTwo are required: one used as a drivermay be a speaker of the tweeter type or

24、a magnetic cutting heador other similar device, depending on the type of couplingchosen for use between the transducer and the specimen. Theother transducer, used as a detector, may be a crystal ormagnetic reluctance type of phonograph cartridge.Acapacitivepickup may be used if desired. The frequenc

25、y response of thetransducer shall be as good as possible with at least a 6.5-kHzbandwidth before 3-dB power loss occurs.4.5 Power Amplifier, in the detector circuit shall be imped-ance matched with the type of detector transducer selected andshall serve as a prescope amplifier.4.6 Cathode-Ray Oscill

26、oscope, shall be any model suitablefor general laboratory work.4.7 Frequency Counter, shall be able to measure frequen-cies to within 61 Hz.4.8 If data at elevated temperature are desired, a furnaceshall be used that is capable of controlled heating and cooling.It shall have a specimen zone 180 mm i

27、n length, which will beuniform in temperature within 65C throughout the range oftemperatures encountered in testing.4.9 For data at cryogenic temperatures, any chamber shallsuffice that shall be capable of controlled heating, frost-free,and uniform in temperature within 65C over the length of thespe

28、cimen at any selected temperature. A suitable cryogenicchamber3is shown in Fig. 2.4.10 Any method of specimen suspension shall be used thatshall be adequate for the temperatures encountered in testingand that shall allow the specimen to vibrate without significantrestriction. Common cotton thread, s

29、ilica glass fiber thread,3Smith, R. E., and Hagy, H. E., “A Low Temperature Sonic ResonanceApparatus for Determining Elastic Properties of Solids,” Internal Report 2195,Corning Glass Works, April, 1961.FIG. 1 Block Diagram of ApparatusC623 92 (2010)2Nichrome, or platinum wire may be used. If metal w

30、iresuspension is used in the furnace, coupling characteristics willbe improved if, outside the temperature zone, the wire iscoupled to cotton thread and the thread is coupled to thetransducer. If specimen supports of other than the suspensiontype are used, they shall meet the same general specificat

31、ions.5. Test Specimen5.1 The specimens shall be prepared so that they are eitherrectangular or circular in cross section. Either geometry can beused to measure both Youngs modulus and shear modulus.However, great experimental difficulties in obtaining torsionalresonance frequencies for a cylindrical

32、 specimen usually pre-clude its use in determining shear modulus, although theequations for computing shear modulus with a cylindricalspecimen are both simpler and more accurate than those usedwith a prismatic bar.5.2 Resonance frequencies for a given specimen are func-tions of the bar dimensions as

33、 well as its density and modulus;therefore, dimensions should be selected with this relationshipin mind. Selection of size shall be made so that, for anestimated modulus, the resonance frequencies measured willfall within the range of frequency response of the transducersused. Representative values

34、of Youngs modulus are 70 3 104kgf/cm2(69 GPa) for glass and 100 3 104kgf/cm2(98 GPa)for glass-ceramics. Recommended specimen sizes are 120 by25 by 3 mm for bars of rectangular cross section, and 120 by4 mm for those of circular cross section. These specimen sizesshould produce a fundamental flexural

35、 resonance frequency inthe range from 1000 to 2000 Hz. Specimens shall have aminimum mass of 5 g to avoid coupling effects; any size ofspecimen that has a suitable length-to-cross section ratio interms of frequency response and meets the mass minimum maybe used. Maximum specimen size and mass are de

36、terminedprimarily by the test systems energy and space capabilities.5.3 Specimens shall be finished using a fine grind 400-gritor smaller. All surfaces shall be flat and opposite surfaces shallbe parallel within 0.02 mm.6. Procedure6.1 Procedure ARoom Temperature TestingPosition thespecimen properly

37、 (see Fig. 3 and Fig. 4). Activate theequipment so that power adequate to excite the specimen isdelivered to the driving transducer. Set the gain of the detectorcircuit high enough to detect vibration in the specimen and todisplay it on the oscilloscope screen with sufficient amplitudeto measure acc

38、urately the frequency at which the signalamplitude is maximized. Adjust the oscilloscope so that asharply defined horizontal baseline exists when the specimen isnot excited. Scan frequencies with the audio oscillator untilspecimen resonance is indicated by a sinusoidal pattern ofmaximum amplitude on

39、 the oscilloscope. Find the fundamentalmode of vibration in flexure, then find the first overtone inflexture (Note 3). Establish definitely the fundamental flexuralmode by positioning the detector at the appropriate nodalposition of the specimen (see Fig. 5). At this point theamplitude of the resona

40、nce signal will decrease to zero. Theratio of the first overtone frequency to the fundamentalfrequency will be approximately 2.70 to 2.75. If a determina-tion of the shear modulus is to be made, offset the coupling tothe transducers so that the torsional mode of vibration may bedetected (see Fig. 3)

41、. Find the fundamental resonance vibrationin this mode. Identify the torsional mode by centering thedetector with respect to the width of the specimen andobserving that the amplitude of the resonance signal decreases1Cylindrical glass jar2Glass wool3Plastic foam4Vacuum jar5Heater disk6Copper plate7T

42、hermocouple8Sample9Suspension wires10Fill port for liquidFIG. 2 Detail Drawing of Suitable Cryogenic ChamberFIG. 3 Specimen Positioned for Measurement of Flexural andTorsional Resonance Frequencies Using Thread or WireSuspensionC623 92 (2010)3to zero; if it does not, the signal is an overtone of fle

43、xure or aspurious frequency generated elsewhere in the system. Dimen-sions and weight of the specimen may be measured before orafter the test. Measure the dimensions with a micrometercaliper capable of an accuracy of 60.01 mm; measure theweight with a balance capable of 610 mg accuracy.NOTE 3It is r

44、ecommended that the first overtone in flexure bedetermined for both rectangular and cylindrical specimens. This is usefulin establishing the proper identification of the fundamental, particularlywhen spurious frequencies inherent in the system interfere (as, forexample, when greater excitation power

45、 and detection sensitivity arerequired for work with a specimen that has a poor response).The fundamental and overtone are properly identified by showing them tobe in the correct numerical ratio, and by demonstrating the properlocations of the nodes for each. Spinner and Tefft recommended usingonly

46、the fundamental in flexure when computing Youngs modulus for arectangular bar because of the approximate nature of Picketts theory.However, for the nominal size of bar specified, the values of Youngsmodulus computed using Eq 1 and Eq 2 will agree within 1 %. When thecorrection factor, T2, is greater

47、 than 2 %, Eq 2 should not be used.6.2 Procedure BElevated Temperature TestingDetermine the mass, dimensions, and frequencies at roomtemperature in air as outlined in 6.1. Place the specimen in thefurnace and adjust the driver-detector system so that all thefrequencies to be measured can be detected

48、 without furtheradjustment. Determine the resonant frequencies at room tem-perature in the furnace cavity with the furnace doors closed,etc., as will be the case at elevated temperatures. Heat thefurnace at a controlled rate that does not exceed 150C/h. Takedata at 25 intervals or at 15-min interval

49、s as dictated byheating rate and specimen composition. Follow the change inresonance frequencies with time closely to avoid losing theidentity of each frequency. (The overtone in flexure and thefundamental in torsion may be difficult to differentiate if notfollowed closely; spurious frequencies inherent in the systemmay also appear at temperatures above 600C using certaintypes of suspensions, particularly wire.) If desired, data mayalso be taken on cooling; it must be remembered, however, thathigh temperatures may damage the specimen, by serio

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1