ASTM D3233-1993(2014) Standard Test Methods for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Pin and Vee Block Methods)《测量液体润滑剂的极端压力特性的标准试验方法 (Falex销和V形块法).pdf

上传人:eastlab115 文档编号:514356 上传时间:2018-12-02 格式:PDF 页数:11 大小:651.03KB
下载 相关 举报
ASTM D3233-1993(2014) Standard Test Methods for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Pin and Vee Block Methods)《测量液体润滑剂的极端压力特性的标准试验方法 (Falex销和V形块法).pdf_第1页
第1页 / 共11页
ASTM D3233-1993(2014) Standard Test Methods for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Pin and Vee Block Methods)《测量液体润滑剂的极端压力特性的标准试验方法 (Falex销和V形块法).pdf_第2页
第2页 / 共11页
ASTM D3233-1993(2014) Standard Test Methods for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Pin and Vee Block Methods)《测量液体润滑剂的极端压力特性的标准试验方法 (Falex销和V形块法).pdf_第3页
第3页 / 共11页
ASTM D3233-1993(2014) Standard Test Methods for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Pin and Vee Block Methods)《测量液体润滑剂的极端压力特性的标准试验方法 (Falex销和V形块法).pdf_第4页
第4页 / 共11页
ASTM D3233-1993(2014) Standard Test Methods for Measurement of Extreme Pressure Properties of Fluid Lubricants (Falex Pin and Vee Block Methods)《测量液体润滑剂的极端压力特性的标准试验方法 (Falex销和V形块法).pdf_第5页
第5页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation: D3233 93 (Reapproved 2014)Standard Test Methods forMeasurement of Extreme Pressure Properties of FluidLubricants (Falex Pin and Vee Block Methods)1This standard is issued under the fixed designation D3233; the number immediately following the designation indicates the year oforiginal ad

2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover two procedures for making apreliminary evalua

3、tion of the load-carrying properties of fluidlubricants by means of the Falex Pin and Vee Block TestMachine.NOTE 1Additional information can be found in Appendix X1 regard-ing coefficient of friction, load gage conversions, and load gage calibrationcurve.1.2 The values stated in inch-pound units are

4、 to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility

5、of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B16/B16M Specification for Free-Cutting Brass Rod, Barand Shapes for Use in Screw MachinesD2670 Test M

6、ethod for Measuring Wear Properties of FluidLubricants (Falex Pin and Vee Block Method)D2783 Test Method for Measurement of Extreme-PressureProperties of Lubricating Fluids (Four-Ball Method)3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 actual gage load, nthe value obtained

7、from the gagewhile running the test and before any corrections are made.3.1.1.1 DiscussionThis gage reading is irrespective of theparticular gage used, and corrections are made by comparisonto a standard reference.3.1.2 direct load, nthat which is applied linearly, bisectingthe angle of the vee bloc

8、k corrected to either the 800 or3000-lbf gage reference.3.1.2.1 DiscussionThis load is equivalent to the true loadtimes the cos 42.3.1.3 true load, nthe sum of the applied forces normal tothe tangents of contact between the faces of one vee block andthe journal pin corrected to the 4500 lbf gage ref

9、erence line.3.1.4 true load failure value, nthe true load at which thelubricant tested can no longer support the applied load resultingin either test pin or shear pin breakage, or inability to maintainor increase load.3.1.4.1 DiscussionThis value is also referred to as thelimit of extreme pressure.4

10、. Summary of Test Methods4.1 Both test methods consist of running a rotating steeljournal at 290 6 10 rpm against two stationary V-blocksimmersed in the lubricant sample. Load is applied to theV-blocks by a ratchet mechanism. In Test Method A (Note 1),increasing load is applied continuously. In Test

11、 Method B(Note 1), load is applied in 250-lbf (1112-N) increments withload maintained constant for 1 min at each load increment. Inboth methods the load-fail value obtained is the criteria forlevel of load-carrying properties. Both methods require cali-bration of the load gage and reporting of test

12、results as true(corrected) loads rather than actual gage loads.NOTE 2Test Method A is referred to as the Falex Run-Up Test. TestMethod B is referred to as the Falex One-Minute Step Test.5. Significance and Use5.1 Evaluations by both test methods differentiate betweenfluids having low, medium, and hi

13、gh levels of extreme-pressureproperties. The user should establish any correlation betweenresults by either method and service performance.NOTE 3Relative ratings by both test methods on the reference fluidscovered in Table 1 and Table 2 are in good general agreement withfour-ball weld-point relative

14、 ratings obtained on these same referencefluids, covered in Test Method D2783.1These test methods are under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.L0.11 on Tribiological Properties of Industrial Fl

15、uids andLubricates.Current edition approved Dec. 1, 2014. Published February 2015. Originallyapproved in 1986. Last previous edition approved in 2009 as D3233 93 (2009)1.DOI: 10.1520/D3233-93R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at

16、serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Falex Pin and Vee Block Test Machine

17、,3illustrated inFig. 1, Fig. 2, and Fig. 3, fitted with 4500-lbf (20 000-N) gageor 3000-lbf (13 350-N) gage.6.2 Required for Calibration:6.2.1 Allen Screw, with attached 10-mm Brinnell ball.46.2.2 Back-Up Plug.46.2.3 Standard Test Coupon,4soft, annealed copper, Hb3739.6.2.4 Brinnell Microscope, or e

18、quivalent.6.2.5 Timer, graduated in seconds and minutes.6.2.6 Rule, steel, 6-in. (approximately 150-mm) long.7. Reagents and Materials7.1 Standard Coined-Blocks,496 6 1 angle, AISI C-1137steel, HRC 20 to 24, surface finish 5 to 10 in. (1.3 107to2.5107m), rms.7.2 Standard Test Journals,414 in. (6.35

19、mm) outside diam-eter by 114 in. (31.75 mm) long,AISI 3135 steel, HRB 87 to 91on a ground flat surface, surface finish 5 to 10 in. (1.3 107to 2.5 107m) rms.7.3 Locking Pins,412 H brass, conforming to SpecificationB16/B16M.7.4 Solvent, safe, nonfilming, nonchlorinated.NOTE 4Petroleum distillate and b

20、enzene, formerly used as solvents inthis method, have been eliminated due to possible toxic effects. Each usershould select a solvent that can meet applicable safety standards and stillthoroughly clean the parts.8. Preparation of Apparatus8.1 Cleaning:8.1.1 Thoroughly clean the V-blocks, test journa

21、ls, lubricantcup, and supports for V-blocks and test journals by washing,successively, with solvent selected in 7.4. Dry the V-blocks,test journals, lubricant cup, and supports by allowing the finalsolvent to evaporate in air.8.1.2 After cleaning, handle the test pieces with care toprevent contamina

22、tion. Particularly, avoid contact of fingerswith mating surfaces of V-blocks and test journals.8.2 Assembly:3The Falex Pin and Vee Block Test Machine, available from the Falex Corp.,1020 Airpark Dr., Sugar Grove, IL 60554 has been found satisfactory for thispurpose. A new model of this machine has b

23、een available since 1983. Certainoperating procedures are different for this new model. Consult instruction manual ofmachine for this information.4Available from Falex Corp., 1020 Airpark Dr., Sugar Grove, IL 60554.TABLE 1 Results of Cooperative Tests on Reference Fluids L-XI-1-2-A, B, C, D, EA(TEST

24、 METHOD A)Labora-toryTestL-XI-1-2-AFail Load, lbfL-XI-1-2-BFail Load, lbfL-XI-1-2-CFail Load, lbfL-XI-1-2-DFail Load, lbfL-XI-1-2-EFail Load, lbfGage True Gage True Gage True Gage True Gage TrueA1212001275840920120012758409204500 +4500 +4100 +4100 +43004500 +39504100 +2600240021001925B12800850860900

25、1000950105010254500 +4500 +4250 +4250 +41004300390041002050195020501950C1272565099091077575010209804500 +4500 +3200 +3200 +39504100290030001350130014601430D121400140010501050110012507709004500 +4500 +3500 +3500 +4500 +4500 +3500 +3500 +2900265021501975E12825750900820100092510601000445044504500 +4500

26、 +41004150447545001825182519701970F121000B990B920B910B100010508008504500 +4500 +4500 +4500 +35002900450035101850172019001720G12800700900800690660800750400037504275400033253150362534501430150016001675H1270070070070010001000100010004500 +4500 +4500 +4500 +37504000375040001900165019001650I1275075060060

27、01250100010008004500 +4500 +3750 +3750 +4500 +4500 +3750 +3750 +1750175014501450Min AvgMax AvgGrand Avg600105085477510379202950C4488C3809C144520631796Repeatability Reproducibilitys = 0.0624 S = 0.140r = 0.179 (TL)DR = 0.402 (TL)DAReference fluids used and described in Test Method D2783.BCalibration

28、curves shifted.CSix laboratories.DTL = average true load, lbf, of sample tested.D3233 93 (2014)28.2.1 Insert the test journal into the test shaft and securewith a new brass locking pin, as shown in Fig. 1 and Fig. 3.8.2.2 Insert the V-blocks into the recesses of the loadingdevice and swing the V-blo

29、cks inward to contact the journal soTABLE 2 Results of Cooperative Tests on Reference Fluids L-XI-1-2-A, B, C, D, EA(TEST METHOD B)Labora-toryTestL-XI-1-2-AFail Load, lbfL-XI-1-2-BFail Load, lbfL-XI-1-2-CFail Load, lbfL-XI-1-2-DFail Load, lbfL-XI-1-2-EFail Load, lbfGage True Gage True Gage True Gage

30、 True Gage TrueA12110011007507501400140010001000415043503750400043504150400037502750220022501750B126706707507509406701000750420039004000375039004200375040002000175020001750C1252052075075052079075010004100 +4100 +3000 +3000 +41004100 +30003000 +1750175017501750D121600160012501250108010807507504500 +4

31、500 +3500 +3500 +4500 +4500 +3500 +3500 +3000330022502500E1270070075075092592510001000385041504250450038503650425040001380185015002000F121075B1075B1000B1000B950950750750335035004250450033503050425037501925156020001500G126606607507506608007501000350032003750350030002800325030001550135017501500H127507

32、507507501000100010001000350040003500400042504000425040001500175015001750I1293093075075091091075075044004400375037504400 +4400 +3750 +3750 +1800180015001500Min AvgMax AvgGrand Avg750125083375010008753625C4375C3932C3125D4125D3837D150023751846Repeatability Reproducibilitys = 0.0624 S = 0.137r = 0.179 (

33、TL)ER = 0.391 (TL)EAReference fluids used and described in Test Method D2783.BCalibration curves shifted.CSeven laboratories.DSix laboratories.ETL = average true load, lbf, of sample tested.FIG. 1 Schematic Diagram of Falex Standard Pin and Vee Block Test MachineD3233 93 (2014)3that the V-grooves ar

34、e aligned with the journal major axis, asshown in Fig. 1 and Fig. 3.8.2.3 Place 60 mL of test lubricant in the lubricant cup andraise the cup so that the V-blocks are immersed in the testlubricant. With highly viscous fluids, open the jaws slightly toensure that the wear surfaces are covered with th

35、e lubricant.8.2.4 Place the automatic loading device, with attachedgage, on the jaw arms.9. Preparation of True Load Calibration Curve9.1 On log-log paper (K then turn off the switch.12.1.2 Remove slack from assembly by moving the ratchetwheel by hand.At this setting the torque gage should read zero

36、,or be adjusted to zero.12.1.3 Actuate the motor, engage the automatic loadingratchet, and increase the load to a gage load equivalent to300-lbf (1334-N) true load (264-lbf direct load), as determinedin 8.1. Disengage the loading ratchet, start the timer, and allowthe machine to run at this loading

37、for a 5-min run-in period.NOTE 8Maintain load at near constant by taking up the load manuallyor automatically by means of the ratchet wheel if necessary.12.2 Test:12.2.1 Re-engage the automatic loading ratchet and leave itengaged until failure (Note 9) or until the highest indicatedactual gage readi

38、ng is reached. Stop the motor at failure or atthe highest indicated actual gage load when no failure isobtained. Record the gage load at failure. Record 4500 lbf(20 000 N) if no failure is obtained.NOTE 9Failure is indicated by (a) breakage of shear pin or test pin, or(b) inability to take up the lo

39、ad automatically by means of the ratchetwheel.12.2.2 Using the calibration curves prepared in Sections 9and 10, determine and record the true load failure equivalent tothe actual gage load failure, or, if no failure, the true loadequivalent to the highest indicated actual gage load, with a plus( + )

40、 sign after the true load value.NOTE 10To convert actual gage load to true load, locate the gage loadon the actual gage load curve. Through this point draw a vertical line tointersect the true load curve. Through this point of intersection draw ahorizontal line to the left-hand or right-hand load sc

41、ale and read the trueload value.TEST METHOD B13. Determination of Actual Gage Load for Run-In and250-lbf (1112-N) True Load Increments13.1 The procedure, Section 14, requires a run-in at anactual gage load equivalent to 300-lbf (1334-N) true load(264-lbf direct load), and testing at incremental gage

42、 loadingsequivalent to 250-lbf (1112-N) true load (224-lbf direct load)over the range from 500 to 4500-lbf (2224 to 20 000-N) trueload (412 to 2885-lbf direct load). Determine the equivalentactual gage loads as prescribed in Section 8, and Test MethodA. Record on a suitable reporting form, such as s

43、hown in Table3.14. Procedure14.1 Run-InUse the same procedure as prescribed in 12.1,Test Method A.14.2 Test:14.2.1 Re-engage the automatic loading ratchet and leave itengaged until the actual gage reading is equivalent to 500-lbf(2224-N) true load (412-lbf direct load), as determined inSection 13. R

44、un for 1 min at this loading.TABLE 3 Suggested Report Form, Test Methods A and B, Showing DataOperator: Laboratory ATest Sample: L-XI-1-2-E Gage Type:Calibration Indentation Results: 500 lbf = 2.13 mm 1500 lbf = 3.53 mm1000 lbf = 2.90 mm 2000 lbf = 4.06 mmTEST METHOD ARun-In: 5 min at 520 lbf actual

45、 gage load, equivalent to 300 lbf true load.Actual Gate Load,lbf, at FailureEquivalent True Load,lbf at FailureTest No. 1 2600 2100Test No. 2 2400 1925TEST METHOD BRun-In: 5 min at 520 lbf actual gage load, equivalent to 300 lbf true load.True Load, lbf Equivalent ActualGage Load, lbfTest No. 1 Test

46、 No. 2500 800 pass pass750 1100 pass pass1000 1400 pass pass1250 1650 pass pass1500 1950 pass pass1750 2200 pass fail2000 2450 pass2250 2750 fail2500 30002750 32003000 34003250 37003500 39003750 41504000 435042504500D3233 93 (2014)6NOTE 11Maintain load at near constant at this load and at subsequent

47、incremental loading by taking up the load by means of the ratchet wheelwhen necessary.NOTE 12Keep the motor running after run-in and throughout subse-quent loadings.14.2.2 Increase actual gage loads in the increments equiva-lent to 250-lbf (1112-N) true load (224-lbf direct load), asdetermined in Se

48、ction 13, running for 1 min at each incrementloading. Record the load at which failure occurs (Note 14, Note15). If no failure is obtained, record the last load run with a plus( + ) sign after the value.NOTE 13Failure is indicated by (a) breakage of shear pin or test pin,or (b) inability to increase

49、 or maintain load by means of the ratchet wheel.NOTE 14If failure occurs during run-up between load increments,record the higher increment load as fail.14.2.3 Determine and record the true load failure equivalentas described in 12.2.2.TEST METHODS A AND B15. Report15.1 Report the true load value at which failure occurred.15.2 If no failure is obtained, report the last true load run,with a plus ( + ) sign after the value.16. Precision and Bias16.1 The precision of these test methods as determined bystatistical examination of interlaboratory

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > ASTM

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有