1、Designation: D 3311 06aAn American National StandardStandard Specification forDrain, Waste, and Vent (DWV) Plastic Fittings Patterns1This standard is issued under the fixed designation D 3311; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification provides standard fitting geometriesand laying lengths for plastic fittings
3、intended for use in drain,waste, and vent applications. (See Specifications D 2661 andD2665.)1.2 Fittings meeting the requirements of this standard speci-fication are designed for use with outside diameter controlledpipe. The inside diameter can vary significantly as the wallthickness and outside di
4、ameter varies and therefore is notsuitable for use as a fitting socket.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information only.2. Referenced Documents2.1 ASTM Standards:2D 2661 Specification for Acrylonitrile-Butad
5、iene-Styrene(ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipeand FittingsD 2665 Specification for Poly(Vinyl Chloride) (PVC) Plas-tic Drain, Waste, and Vent Pipe and Fittings3. Requirements3.1 Fittings shall conform to the geometries and layinglengths as shown in Tables 1-45 and Fig. 1. Toleranc
6、es shall be6116 in. unless otherwise specified.3.2 Spigot and hub dimensions shall conform to the require-ments of the referencing standard.3.3 The exact outside shape of a fitting is not determined bythe outline drawings shown in this specification but rather bythe socket dimensions, wall thickness
7、 requirements, waterway,laying lengths, and any other critical dimensions that may bespecified.3.4 The pitch of sockets for patterns with 90 angles (exceptvent fittings) shall be14 in./ft or 1 12 min.3.5 On double reducing sanitary tees, the G2 dimension onbranches will be calculated on the larger s
8、ize and centerlinesshall remain the same for both branches.3.6 All other dimensions, materials and property require-ments shall be in conformance with the referencing standard.4. Keywords4.1 DWV; fittings; plastic; Schedule 40; thermoplastic1This specification is under the jurisdiction of ASTM Commi
9、ttee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.Current edition approved Dec. 1, 2006. Published December 2006. Originallyapproved in 1974. Last previous edition approved in 2006 as D 3311 06.2For referenced ASTM standards, visit the ASTM website, www
10、.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.TABLE
11、 1 Bends, in. (mm)Nominal Pipe Size14 BendLong Sweep14 Bend18 Bend16 Bend116 BendGGGGG114 1916 (40) 214 (57) 1 (25)78 (22)716 (11)112 134 (44) 234 (70) 118 (29) 1 (25)12 (13)22516 (59) 314 (83) 112 (38) 1516 (33)1116 (17)33116 (78) 4116 (103) 134 (44) 11116 (43)1316 (21)4378 (98) 41516 (125) 2316 (5
12、6) 2116 (52) 1 (25)6 5 (min) (127) 9 (229) 2 (min) (51) 338 (86) 112 (38)8 6 (152) . . . 2116 (52) . . . 112 (38)TABLE 2 Bends with Inlets, in. (mm)Nominal Pipe Size14 Bend with Low Heel InletLong-Sweep14 Bend with Low HeelInletLong-Sweep14 Bend with High Heel InletGN G N G NG3by3by112 3116 (78) 431
13、6 (106) 4116 (103) 434 (121) . . . . . . . . .3by3by2 3116 (78) 4716 (113) 4116 (103) 41516 (125) 4116 (103) 558 (143) 214 (57)4by4by2 378 (98) 5716 (138) 41516 (125) 6 (152) . . . . . . . . .D 3311 06a2TABLE 3 Sanitary Tees, 45 Wyes, Combination Wyes and18 Bends, in. (mm)Nominal Pipe SizeSanitary T
14、ee Single and DoubleA45 Wye, Single and DoubleCombination Wye and 1/8 Bend Single andDoubleGN GJ GN GJ GN GJ11434 (19) 1916 (40) 1116 (27) 2916 (65)716 (11) 21516 (75)112 1 (25) 134 (44) 118 (29) 278 (73)12 (13) 338 (86)2138 (35) 2516 (59) 138 (35) 358 (92) 1 (25) 412 (114)311316 (46) 3116 (78) 158
15、(41) 5 (127) 118 (29) 6516 (160)4214 (57) 378 (98) 178 (48) 638 (162) 11316 (46) 858 (219)6312 (89) 5 (127) 134 (44) 8716 (214)BB8412 (114) 6 (152) 238 (60) 1134 (298)ANon-reducing double sanitary tees are for vent use only.BCombination wye and18 bend is assembled from two standard fittings.TABLE 4
16、Reducing Sanitary Tees, 45 Wyes, Combination Wyes, and18 Bends, in. (mm)Nominal Pipe SizeSanitary Tee, Reducing Single and DoubleA45 Wye, Reducing Single and DoubleCombination Wye and18 Bend ReducingSingle and DoubleG1 G2 G3 G4 G1 G2 G3 G1 G2 G3112 by 114 by 1141116 (17)B112 (38)B11116 (43)B11116 (4
17、3)B112 by 114 by 112 1 (25) 134 (44) 134 (44) 134 ()112 by 112 by 1141316 (21) 11116 (43) 11316 (46) 11316 (46) 12 (13) 314 (83) 3316 (81)2by114 by 112 1316 (30) 11516 (49) 2316 (56) 2316 (56)2by112 by 112 1316 (30) 11516 (49) 2316 (56) 2316 (56)34 (19)B21316 (71)B21516 (75)B 916 (14) 31116 (94) 358
18、 (92)2by112 by 2 138 (35) 2516 (59) 2516 (59) 2516 (50) 1 (25)B312 (89)B338 (86)B1 (25) 412 (114) 412 (114)2by2by114 1316 (30) 11516 (49) 2316 (56) 2316 (6)2by2by112 1316 (30) 11516 (49) 2316 (56) 2316 (56) 1116 (27) 3516 (84) 3716 (87)916 (14) 31116 (170) 358 (92)3by3by1121516 (24) 134 (44) 2916 (6
19、5) 2916 (65)12 (13) 334 (95) 4516 (110)18 (3) 3716 (87) 414 (108)3by3by2 1316 (30) 218 (54) 278 (73) 278 (73)78 (22) 418 (105) 458 (117)716 (11) 434 (121) 5516 (135)3by3by2by1121516 (24)B2116 (52)B2716 (62)B212 (64)B4by4by112 1116 (27)B2 (51)B314 (83)B314 (83)B0(0)B3516 (84)B31516 (100)B4by4by2 118
20、(29) 2116 (52) 3516 (84) 3516 (84)38 (10) 41116 (119) 5916 (141)516 (8) 434 (121) 578 (149)4by4by3 134 (44) 3 (76) 3916 (90) 3916 (90) 1116 (27) 5916 (141) 6 (152) 1116 (27) 638 (162) 678 (175)6by6by3 316 (5)B61516 (176)B7716 (189)B 1116 (17)B71316 (198)B81316 (224)B6by6by4 2316 (56)B358 (92)B4516 (
21、110)B4516 (110)B 316 (5)B61116 (170)B7716 (189)B 916 (14)B71316 (198)B81516 (227)B8by8by4 258 (67) 418 (105) 514 (133) 514 (133)38 (10) 758 (194) 858 (219)CCC8by8by6 3916 (90) 41316 (122) 512 (140) 512 (140) 1 (25) 912 (241) 91316 (249)ANon-reducing double sanitary tees are for vent use only.BThis d
22、imension is a minimum with no upper maximum limit.CCombination Wye and18 bend is assembled from two standard fittings.D 3311 06a3TABLE 5 60 Wyes, Single, and Double, in. (mm)Nominal PipeSizeGN GJ112 118 (40) 278 (73)2138 (37) 358 (92)3158 (37) 5 (127)TABLE 6 Fixture Tees, in. (mm)Nominal Pipe Size G
23、1 G2 G3112 1916 (40) 1316 (30) 114 (32)2by112 by 112 1716 (37) 1316 (30) 114 (32)2by2by112 1716 (37) 1516 (33) 114 (32)TABLE 7 Cleanout Tees, in. (mm)Nominal PipeSizeGI112 1316 (30)58 (16)2112 (38)58 (16)3178 (48)34 (19)4212 (64)78 (22)TABLE 8 60 Reducing Wyes, Single and Double, in. (mm)Nominal Pip
24、eSizeG1 G2 G32by2by112 1116 (27) 3716 (87) 3716 (87)3by3by11212 (13) 334 (95) 4516 (110)3by3by278 (22) 418 (105) 458 (117)TABLE 9 Molded Nipples, in. (mm)NominalPipe SizeOD ID Length112231.9002.3753.5001.5001.9392.90012-in. increments fromclose to 18 in. longTABLE 10 Vent Tees and14 Bend Vents, in.
25、(mm)Nominal PipeSizeVent Tee14 Bend Vent114 1 (25) 1 (25)112 1316 (30) 1316 (30)2112 (38) 112 (38)3178 (48) 178 (48)4212 (64) 212 (64)D 3311 06a4TABLE 11 Reducing Vent Tees, Single, and Double, in. (mm)Nominal Pipe Size GN GJ2by112 by 112 1316 (30) 112 (38)2by2by112 1316 (30) 112 (38)3by3by112 1316
26、(30) 178 (48)3by3by2 112 (38) 178 (48)TABLE 12 Bushings, in. (mm)Nominal PipeSizeStyle 1 (a and b)AStyle 2 Style 3L CM R L1 CM N L112 by 1141516 (24)316 (5)316 (5) . . . 1(25)2by114 1116 (27)516 (8)316 (5) . . . 118 (29)2by112 1116 (27)516 (8)316 (5) . . . 1332 (28)3by112 134 (44) 1 (25)14 (6) 134 (
27、44)34 (19)14 (6) 112 (38)3by2 134 (44)78 (22)14 (6) 134 (44)78 (22)14 (6) 158 (41)4by2 2(51) 118 (29)14 (6) 2 (51)78 (22)14 (6) .4by3 2(51)12 (13)14 (6) 2 (51) 112 (38)14 (6) .6by3 3516 (84) 11316 (97)516 (8) . . . .6by4 312 (89) 134 (44)12 (13) . . . .8by4 458 (117) 278 (73)58 (16) . . . .8by6 458
28、(117) 158 (41)58 (16) . . . .ANo less than four ribs shall be used to support walls.D 3311 06a5TABLE 13 Couplings, Adapters, in. (mm)Nominal Pipe SizeCoupling Female Adapter Male AdapterFemale FittingAdapterDN,min N,min N,min A, max N,min114 1.600 to 1.38018 (3)14 (6)316 (5) 1.290 (32.77)532 (4)112
29、1.840 to 1.61018 (3)14 (6)316 (5) 1.552 (39.42)532 (4)2 2.320 to 2.06718 (3)14 (6)316 (5) 2.067 (52.50)532 (4)3 3.440 to 3.068316 (5)516 (8)38 (10) 3.068 (77.93)732 (6)4 4.440 to 4.02614 (6)1132 (9)38 (10) 4.026 (102.26)14 (6)6 6.550 to 6.06514 (6) . . . .8 8.655 to 8.61014 (6) . . . .TABLE 14 Pipe
30、Increasers, in. (mm)NominalPipe SizeN,min114 by 1121332 (10)112 by 21732 (13)112 by 3 1332 (28)2by378 (22)2by4 138 (35)3by41516 (24)D 3311 06a6TABLE 15 Trap Adapters, in. (mm)Without stop With StopNominalPipe SizeN,min A,min114316 (5) 1.250 (32)112316 (5) 1.500 (38)2316 (5) 2.000 (51)114 by 112316 (
31、5) 1.250 (32)TABLE 16 Pipe Plugs, in. (mm)NominalPipe SizeIWQ11412 (13) 1 (25) 1 (25)11258 (16) 138 (35) 1 (25)258 (16) 138 (35) 114 (32)21234 (19) 112 (38) 114 (32)334 (19) 134 (44) 158 (41)31234 (19) 134 (44) 158 (41)478 (22) 178 (48) 2 (51)6 1 (25) 2 (51) 214 (32)8138 (35) 238 (60) 312 (89)D 3311
32、 06a7TABLE 17 Hubs, in. (mm)NominalPipe SizeACNAJCJN2 . . . 2.94(74.7) 238 (60)38 (10)3 3.448 (87.58) 11116 (43)516 (8) 3.94 (100.1) 258 (67)716 (11)4 4.493 (114.12) 11516 (49)1132 (9) 4.94 (125.5) 278 (73)12 (13)Reducing 4 by 3 4.493 (114.12) 11516 (49)516 (8) 4.94 (125.5) 278 (73)716 (11)TABLE 18
33、Spigots, in. (mm)NominalPipe SizeL2,min L1,min L3,minMANmax min2312 (89) 458 (117)38 (10) 2.75 (69.9) 2.63 (66.8) 2.00 (50.8)3334 (95) 558 (143)38 (10) 3.88 (98.6) 3.63 (92.2) 3.00 (76.2)4 4 (102) 618 (156)38 (10) 4.88 (124.0) 4.63 (117.6) 4.00 (101.6)D 3311 06a8TABLE 19 Reducing Spigots, in. (mm)No
34、minalPipe SizeL2 min L1 min L3 minMAJmax min2by112 312 (89) 414 (108)38 (10) 2.75 (69.9) 2.63 (66.8) 2.00 (50.8)3by112 334 (95) 412 (114)38 (10) 3.88 (98.6) 3.63 (92.2) 3.00 (76.2)3by2 334 (95) 458 (117)38 (10) 3.88 (98.6) 3.63 (92.2) 3.00 (76.2)4 by 2 4 (102) 478 (124)38 (10) 4.88 (124.0) 4.63 (117
35、.6) 4.00 (101.6)4 by 3 4 (102) 512 (140)38 (10) 4.88 (124.0) 4.63 (117.6) 4.00 (101.6)TABLE 20 P Traps, in. (mm)NominalPipe Sizemin GJ min GGJ min GGN min GN min R114 418 (105) 338 (86) 3 (76) 138 (35) 158 (41)112 4732 (107) 358 (92) 3 (76) 138 (35) 158 (41)2714 (184) 4116 (103) 5 (127) 214 (57) 212
36、 (64)38716 (214) 6516 (160) 614 (159) 258 (67) 318 (79)4101316 (275) 778 (200) 8116 (205) 3716 (87) 4116 (103)D 3311 06a9TABLE 21 Double Fixture Fitting, in. (mm)Nominal Pipe Size G1 G2 G3 G411238 (10) 3916 (90) 2716 (62) 2716 (62)238 (10) 4916 (116) 3116 (78) 3116 (78)312 (13) 634 (171) 412 (114) 4
37、12 (114)Reducing:2by112 by 112 by 11238 (10) 3916 (90) 2716 (62) 2716 (62)2by112 by2by238 (10) 4916 (116) 3116 (78) 3116 (78)2by112 by2by11238 (10) 4916 (116) 3116 (78) 3116 (78)TABLE 22 Double Fixture Fitting, in. (mm)Interchanges with Double Fixture FittingsNominalPipe SizeDouble Fixture FittingG1
38、 G2 G3 G4 R1 R211238 (10) 318 (79) 21116 (68) 21116 (68) 358 (92) 358 (92)238 (10) 414 (108) 312 (89) 312 (89) 412 (114) 412 (114)312 (13) 614 (159) 41516 (125) 41516 (125) 658 (168) 658 (168)Reducing2by112 by 112 by11238 (10) 318 (79) 278 (73) 278 (73) 358 (92) 358 (92)2by112 by 112 by 238 (10) 414
39、 (108) 278 (73) 312 (69) 358 (92) 412 (114)2by112 by2by238 (10) 414 (108) 312 (89) 312 (89) 412 (114) 412 (114)3by2by3by312 (13) 614 (159) 41516 (125) 41516 (125) 658 (168) 658 (168)D 3311 06a10TABLE 23 Single and Double Long Turn Tee, in. (mm)Interchanges with Combination Wye 1/8 BendNominalPipe Si
40、zeSingle and Double Long Turn TeeG1 G2 N R11438 (10) 3716 (87) 3116 (78) 434 (121)112716 (11) 31516 (100) 312 (89) 578 (149)21116 (17) 518 (130) 4716 (113) 7 (178)31116 (27) 7916 (192) 612 (165) 1018 (257)4112 (38) 10 (254) 812 (216) 1314 (337)6212 (64) 1538 (391) 1278 (327) 19 (483)TABLE 24 Single
41、and Double Long Turn Tee Reducing, in. (mm)Interchanges with Reducing Combination Wye 1/8 BendNominal Pipe SizeSingle and Double Long Turn Tee ReducingG1 G3 N G2 R112 by 114 by 11438 (10) 358 (92) 3116 (78) 3716 (87) 434 (121)112 by 112 by 11438 (10) 358 (92) 3116 (78) 3716 (87) 434 (121)2by112 by 1
42、12716 (11) 4316 (107) 312 (89) 31516 (100) 578 (200)2by112 by 21116 (17) 518 (130) 4716 (113) 518 (130) 7 (178)2by2by11438 (10) 31316 (97) 3116 (78) 3716 (87) 434 (121)2by2by112716 (11) 4316 (102) 312 (89) 31516 (100) 578 (149)3by3by112716 (11) 434 (121) 312 (89) 31516 (100) 578 (149)3by3by21116 (17
43、) 51116 (128) 4716 (113) 518 (130) 7 (178)4by4by11238 (10) 5316 (132) 3916 (90) 31516 (100) 578 (149)4by4by258 (16) 618 (156) 412 (114) 518 (130) 7 (178)4by4by3 1116 (27) 8116 (205) 612 (165) 7916 (192) 1018 (257)6by6by2916 (14) 718 (181) 4916 (116) 518 (130) 7 (178)6by6by31516 (24) 9116 (230) 658 (
44、168) 7916 (192) 1018 (257)6by6by4 112 (38) 11 (279) 812 (216) 10 (254) 1314 (337)6by6by5 2(51) 13516 (338) 1034 (273) 1234 (324) 16 (406)D 3311 06a11TABLE 25 Three-Way EII, in. (mm)NominalPipe SizeG1 G2 G3112 134 (44) 134 (44) 134 (44)22516 (59) 2516 (59) 2516 (59)33116 (78) 3116 (78) 3116 (78)4378
45、(98) 378 (98) 378 (98)Reducing2by112 by 112 (short) 158 (41) 158 (41) 158 (41)3by2by3 3116 (78) 278 (73) 3116 (78)2by112 by 112 (long) 11516 (49) 2316 (56) 2316 (56)TABLE 26 Two Way Cleanout, in. (mm)Nominal Pipe Size G344116 (103)41516 (125)D 3311 06a12TABLE 27 Sanitary Tees, with Side Inlet, in. (
46、mm)Nominal Pipe Size G1 G2 G3 G4 G5Left-Hand Side Inlet112 by 112 by 112 by 112 234 (70) 134 (44) 134 (44) 134 (44) 134 (44)2by2by112 by 112 31116 (94) 2516 (59) 2516 (59) 2516 (59) 2516 (59)3by3by2by112 3516 (84) 218 (54) 278 (73) 2916 (65) 218 (54)3by3by2by2 3516 (84) 218 (54) 278 (73) 278 (73) 21
47、8 (54)3by3by3by112 478 (124) 3116 (78) 3116 (78) 2916 (65) 31116 (94)3by3by3by2 478 (124) 3116 (78) 3116 (78) 278 (73) 31116 (94)4by4by4by2 618 (156) 378 (98) 378 (98) 3516 (84) 5 (127)Right-Hand Side Inlet3by3by2by112 3516 (84) 218 (54) 278 (73) 2916 (65) 218 (54)3by3by2by2 3516 (84) 218 (54) 278 (73) 278 (73) 218 (54)3by3by3by112 478 (124) 3116 (78) 3116 (78) 2916 (65) 311