ASTM D6656-2014a red 0223 Standard Test Method for Determination of Chromic Oxide in Wet Blue &40 Perchloric Acid Oxidation&41 .pdf

上传人:towelfact221 文档编号:523157 上传时间:2018-12-04 格式:PDF 页数:5 大小:72.92KB
下载 相关 举报
ASTM D6656-2014a red 0223 Standard Test Method for Determination of Chromic Oxide in Wet Blue &40 Perchloric Acid Oxidation&41 .pdf_第1页
第1页 / 共5页
ASTM D6656-2014a red 0223 Standard Test Method for Determination of Chromic Oxide in Wet Blue &40 Perchloric Acid Oxidation&41 .pdf_第2页
第2页 / 共5页
ASTM D6656-2014a red 0223 Standard Test Method for Determination of Chromic Oxide in Wet Blue &40 Perchloric Acid Oxidation&41 .pdf_第3页
第3页 / 共5页
ASTM D6656-2014a red 0223 Standard Test Method for Determination of Chromic Oxide in Wet Blue &40 Perchloric Acid Oxidation&41 .pdf_第4页
第4页 / 共5页
ASTM D6656-2014a red 0223 Standard Test Method for Determination of Chromic Oxide in Wet Blue &40 Perchloric Acid Oxidation&41 .pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D6656 14D6656 14aStandard Test Method forDetermination of Chromic Oxide in Wet Blue (PerchloricAcid Oxidation)1This standard is issued under the fixed designation D6656; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,

2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of chromic oxide in wet blue that has been partly or completely

3、tanned withchromium compounds. In general, the samples will contain chromium content between 1 % and 5 % when calculated as chromicoxide expressed upon a dry basis otherwise referred to as moisture-free basis (mfb).1.2 The values stated in SI units are to be regarded as standard. No other units of m

4、easurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatoryl

5、imitations prior to use. See Section 9 for specific safety hazards.2. Referenced Documents2.1 ASTM Standards:2D6658 Test Method for Volatile Matter (Moisture) of Wet Blue by Oven DryingD6659 Practice for Sampling and Preparation of Wet Blue for Physical and Chemical TestsE180 Practice for Determinin

6、g the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals(Withdrawn 2009)3E177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE177 Practice for

7、Use of the Terms Precision and Bias in ASTM Test Methods3. Terminology3.1 DefinitionsThe terms and definitions employed within this method are commonly used in normal laboratory practice andrequire no special comment.4. Summary of Test Method4.1 The perchloric acid method may be applied to wet blue.

8、 Accurately weighed wet blue samples are digested in a blend ofconcentrated nitric acid and a prepared “oxidation mixture” consisting of sulfuric and perchloric acids. Once completed, oxidationof all tri-valent to haxavalent chrome is executed by controlled heating. Upon dilution, the chromium is in

9、directly (back) titratedvolumetrically with standardized thiosulfate using released iodine as the titrate. The perchloric acid method requires lessmanipulation than procedures based upon fusion of the ash. However, care must be taken because of potential hazards in the useof this reagent.5. Signific

10、ance and Use5.1 The procedure described is specific for chromium in wet blue. Vanadium is the only common interfering element and israrely present in quantity. The precision and accuracy of the methods are usually, at least, as good as the sampling of wet blue itself.5.2 The chromium content of wet

11、blue is related to the degree of tannage obtained, and hence may be a matter for specificationin the purchase of wet blue. The procedure described provides adequate accuracy for this purpose.1 This test method is under the jurisdiction of ASTM Committee D31 on Leather and is the direct responsibilit

12、y of Subcommittee D31.02 on Wet Blue.Current edition approved April 1, 2014. Published June 2014. Originally approved in 1996. Last previous edition approved in 20102014 as D6656 - 01(2010)D6656 - 14.1. DOI: 10.1520/D6656-14.10.1520/D6656-14A.2 For referencedASTM standards, visit theASTM website, ww

13、w.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM sta

14、ndard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cas

15、es only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Analytical Balanceaccurate and calibrated to 0.001 g.6.2 Erlenme

16、yer Flasks250 mL capacity or equivalent.6.3 Burette50 mL capacity of suitable calibration grade, minimum calibration of 0.1 mL.6.4 Glass Anti-Bumping Beadsor equivalent.6.5 Measuring Cylindersof 50 mL capacity or equivalent.6.6 Small Glass Filter Funnel.6.7 Dessicatorof suitable size and design and

17、charged with fresh dessicant.6.8 Weighing Vesselsof suitable size and design.6.9 Drying Ovenwith accurate variable temperature controls.7. Reagents and Materials7.1 Purity of ReagentsAnalytical Reagent (AR) grade shall be used in all tests. Unless otherwise indicated, it is intended thatall reagents

18、 shall conform to specifications of the Committee on Analytical Reagents of the American Chemical Society, wheresuch specifications are available.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accura

19、cy of the determination.7.2 Purity of WaterUnless otherwise indicated, reference to water shall be understood to mean distilled water or water of equalpurity.7.3 Commercial ReagentsThe use of commercially available pre-standardized analytical reagents and solutions is appropriate,providing those rea

20、gents and solutions have been prepared according to and conform to the previously mentioned specifications(see 7.1).7.4 Nitric Acid(HNO3), 70 % w/w.7.5 Perchloric Acid(HClO4), 60-62 % w/w. 70 % or 72 % w/w perchloric acid may be substituted; however, storage issomewhat more hazardous.7.6 Sulfuric Ac

21、id(H2SO4), 96-98 % w/w.7.7 Potassium Iodide(KI), 99-100 % purity.7.8 Potassium Iodide Solution(KI), 10 % w/w. Dissolve 10 g (6 0.1 g) of potassium iodide into 100 ml of water.7.9 Starch Indicator Solution2 % or equivalent. Prepared according to accepted procedures available in analytical handbooks.7

22、.10 Oxidizing MixtureMix 1666 mL of concentrated sulfuric acid into an appropriate glass container that contains 2500 mLof perchloric acid using extreme caution while adding. Cool the mixture to room temperature before use.7.11 Phosphoric Acid(H3PO4), 40 % w/w. Dilute 45 mL of 85 % phosphoric acid w

23、ith water to 100 ml.7.12 Hydrochloric Acid(HCl, 1:1 dilution of 37 %, w/w). Used in standardization of thiosulfate solution.7.13 Potassium Dichromate(K2Cr2O7). Used in standardization of thiosulfate solution.7.14 Sodium Carbonate(Na2CO3). Used in preparation of thiosulfate solution.7.15 Sodium Thios

24、ulfate(Na2S2O3 5H2O). Used to prepare thiosulfate solution.7.16 Sodium Thiosulfate Standard Solution(Na2S2O3), 0.1N (6 0.0002). Dissolve 24.85 g of sodium thiosulfate (Na2S2O3 5H2O) in previously boiled water, add 1.00 g of sodium carbonate (Na2CO3) and dilute to 1000 mL.8. Standardization8.1 Dry po

25、tassium dichromate (K2Cr2O3) in an oven at 130 C for 2 h and cool in a dessicator. Once cool, weigh about 0.2 g(6 0.0001 g) of this dry potassium dichromate into a clean 250 ml, glass-stoppered Erlenmeyer flask. Dissolve in 50 mL water;add 4 ml of hydrochloric acid (HCl, 1:1) and 20 ml of KI solutio

26、n. Stopper the flask and allow to stand for 5 min. in the dark.Titrate with the thiosulfate solution that is to be standardized. When the solution color has faded to brownish-green, add 2 ml of2 % starch solution and continue titrating until the deep blue color changes to a clear green. Record the v

27、olume of titrant used.Calculate the Normality of the thiosulfate solution as follows:Normality5A0.049033B!4 Reagent Chemicals, American Chemical Society Specifications , American Chemical Society, Washington, DC. For suggestions on the testing of reagents not listed bythe American Chemical Society,

28、see Analar Standards for Laboratory Chemicals, BDH Ltd. Poole, Dorset, UK and the United States Pharmacopoeia and NationalFormulary, U.S. Pharmacopoeial Convention, Inc. (USPC), Rockville, MD.D6656 14a2where:A = grams of K2Cr2O7 used, andB = ml required for titration.8.2 Shelf LifeThe thiosulfate so

29、lution is relatively stable. However, it should be re-standardized at least once every month.Alternatively, a commercially available pre-standardized analytical solution may be substituted.9. Hazards9.1 Chemicals used can be harmful or explosive, or both.9.2 The improper use of perchloric acid can l

30、ead to violent and serious explosions. In general, these can be traced to situationswhere concentrated perchloric acid has come in contact with organic or easily oxidized materials.9.3 The exact procedures given must be followed and the digestion, once started, should be kept from possible contact w

31、ithother organic matter. The digestion should never be allowed to boil dry. The perchloric acid should never be used without theaccompanying use of nitric and sulfuric acids.9.4 Any spills involving perchloric acid should be flushed with water and a liquid acid neutralizer.9.5 The use of a perchlori

32、c acid hood, reserved for perchloric acid digestion, equipped with wash-down facilities andconstructed entirely of non-porous inorganic material is required.9.6 Perchloric acid bottles should be stored on a ceramic or non-porous tray or shelf and never on a wooden or pervious shelf.9.7 Perchloric ac

33、id must not be permitted to go dry in the presence of organics, metals or metal salts.9.8 It is advisable to keep only a one pound (0.45 kg) bottle of acid in a working area.10. Test Specimens10.1 The test specimen shall be 3-5 g of wet blue from a composite sample prepared according to Practice D66

34、59 and weighedto an accuracy of 0.001 g.11. Procedure11.1 Accurately weigh between 3 and 5 g (6 0.001 g) of the prepared wet blue sample into a 250 mL Erlenmeyer flask. Recordthe weight to the nearest 0.001 g.11.2 Using extreme care, add 20 mL of nitric acid (HNO3) to the flask.11.3 Next, carefully

35、and slowly add 25 mL of the Oxidizing Mixture to the flask.11.4 Add a few glass anti-bumping beads (these will allow the solution to boil evenly), then place the filter funnel into the neckof the flask.11.5 Under the perchloric hood, heat the solution gently under reflux conditions (using the funnel

36、 as a condenser in the neckof the flask) until all organic matter is destroyed and the solution color changes to a clear red-orange, indicating oxidation of thechromium. Do not allow the sample to boil to dryness.11.6 Heat the solution for an additional 2 min to ensure complete oxidation; then rapid

37、ly cool the solution, rinse and removethe funnel, then dilute to 125 mL with water. Rapid cooling can be achieved with the use of a cold water bath.11.7 Re-heat the solution to boiling and continue for 7 to 10 min in order to expel and any chlorine or oxides of nitrogen.11.8 Remove the flask from th

38、e heat and allow the solution to cool to room temperature.11.9 Once cool, add 30 mL of phosphoric acid and 25 mL of the 10 % potassium iodide solution, then stopper the flask.11.10 Place the flask in the dark and allow to stand for 5 min to allow complete release of iodine (dark brown color).11.11 T

39、itrate volumetrically with 0.1 N, standardized sodium thiosulfate.11.12 When the solution color has faded to a pale yellow-brown, add approximately 2 ml of the starch indicator solution.Continue the titration until the deep blue color changes to a clear blue-green.11.13 Record the titration volume.1

40、1.14 If the titration volume is less than 5 mLor more than 50 ml, repeat the entire procedure, after adjusting the sample weightso that the titration volume is toward the middle of the burette.11.15 Calculate the results in accordance with Section 12.12. Calculation12.1 Calculate the chromium conten

41、t as the percentage of chromic oxide (Cr2O3) in the leather as follows:Chromic Oxide Cr2O3!,%5T 3N 3E 3100W!D6656 14a3where:T = titration volume of sodium thiosulfate solution used in milliliters (ml),N = Normality of the sodium thiosulfate solution,E = 0.025332 = chromic oxide (Cr2O3) equivalence w

42、eight per milliliter (g/mL),W = weight of original wet blue specimen (as received) in grams (g), and100 = conversion to percent.12.2 The above calculation provides the Cr2O3 content of the wet blue on an “as received” basis. Since the chromium contentof wet blue is expressed upon a dry (moisture-fre

43、e) basis, a moisture determination must be run in accordance with Test MethodD6658. If D is found to be the moisture content in the wet blue sample, then calculate the Cr2O3 upon a dry basis (mfb) as follows:Chromic Oxide Cr2O3!,%5T 3N 3E 3100W! 3112D100!#!where:T, N, E and W = the same significance

44、 as in the previous calculation.13. Report13.1 Report the percentage of Cr2O3 to the nearest 0.01 % for each and all values.13.2 Duplicate runs that agree within 0.09 % absolute are acceptable for averaging (95 % confidence level).14. Precision and Bias14.1 ReproducibilityThe average difference betw

45、een two results (each the average of duplicate determinations) obtained byanalysis in different laboratories will approximate 0.06 % on an absolute basis. Two such values should be considered suspect(95 % confidence level) if they differ by more than 0.2 % absolute.14.2 BiasThe test method yields re

46、sults that average 1.75 % lower in relation to the standard sample of NBS K2Cr2O7. The99 % confidence limits on this value are 1.50 to 2.00 %, as determined by triplicate analyses in five laboratories.NOTE 1The estimates of checks for duplicates and reproducibility in 14.1 and 14.2 are based on an i

47、nterlaboratory study of four leather samples runin triplicate in each of laboratories. The precision statements were developed5 using Practice E180.14.3 Areal world precision statement was determined through statistical examination6 of 139 results from 9 laboratories, on 16materials over nearly 2 ye

48、ars. Practice E691 was followed for the design and analysis of the data. The terms below (repeatabilityand reproducibility) are used as specified in Practice E177.14.3.1 Repeatability (r)The difference between repetitive results obtained by the same operator in a given laboratory applyingthe same te

49、st method with the same apparatus under constant operating conditions on identical test material within short intervalsof time would in the long run, in the normal and correct operation of the test method, exceed the following values only in one casein 20.14.3.2 Reproducibility (R)The difference between two single and independent results obtained by different operators applyingthe same test method in different laboratories using different apparatus on identical test material would, in the long run, in thenormal and correct operation

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > ASTM

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1