ASTM D7496-2009 346 Standard Test Method for Viscosity of Emulsified Asphalt by Saybolt Furol Viscometer《用赛波特糠醛粘度计测定乳化沥青粘性的标准试验方法》.pdf

上传人:twoload295 文档编号:525656 上传时间:2018-12-04 格式:PDF 页数:3 大小:66.44KB
下载 相关 举报
ASTM D7496-2009 346 Standard Test Method for Viscosity of Emulsified Asphalt by Saybolt Furol Viscometer《用赛波特糠醛粘度计测定乳化沥青粘性的标准试验方法》.pdf_第1页
第1页 / 共3页
ASTM D7496-2009 346 Standard Test Method for Viscosity of Emulsified Asphalt by Saybolt Furol Viscometer《用赛波特糠醛粘度计测定乳化沥青粘性的标准试验方法》.pdf_第2页
第2页 / 共3页
ASTM D7496-2009 346 Standard Test Method for Viscosity of Emulsified Asphalt by Saybolt Furol Viscometer《用赛波特糠醛粘度计测定乳化沥青粘性的标准试验方法》.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation: D 7496 09Standard Test Method forViscosity of Emulsified Asphalt by Saybolt FurolViscometer1This standard is issued under the fixed designation D 7496; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r

2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method utilizes the Saybolt Furol viscometer tomeasure the consistency of emulsified asphalt. It is applicableto a

3、ll the emulsified asphalts specified in Specifications D 977and D 2397.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use

4、. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D88 Test Method for Saybolt ViscosityD 244 Test Methods and Practices for Em

5、ulsified AsphaltsD 977 Specification for Emulsified AsphaltD 2397 Specification for Cationic Emulsified AsphaltE1 Specification for ASTM Liquid-in-Glass ThermometersE11 Specification for Wire Cloth and Sieves for TestingPurposes3. Significance and Use3.1 Viscosity has significance in the use of emul

6、sifiedasphalt because it is a property which affects their utility. Whenused in application types of construction, the material must bethin enough to be uniformly applied through the spray bar ofdistributor, yet thick enough so that it will not flow from thecrown or grade of the road. For mixing gra

7、de emulsions, theviscosity may affect mixibility and resulting thickness of filmon the aggregate. The viscosity of many emulsions is affectedby shear. Therefore, strict adherence to test procedure isnecessary to achieve precision.4. Sample Conditioning for Testing4.1 All emulsified asphalts shall be

8、 properly stirred toachieve homogeneity before testing.4.2 All emulsified asphalts with the viscosity testing re-quirements of 50C shall be heated to 50 6 3C in the originalsample container in a water bath or oven. The container shouldbe vented to relieve pressure. After the sample reaches 50 63C, s

9、tir the sample to achieve homogeneity.4.3 Emulsified asphalts with a viscosity testing require-ments to 25C should be mixed or stirred at 25 6 3C in theoriginal sample container to achieve homogeneity.NOTE 1Emulsified asphalts with viscosity testing requirements of25C may be heated and stirred as sp

10、ecified in 4.2, if necessary. In theevent the 4.2 method is used, the sample should be cooled to 25 6 3Cbefore testing.5. Apparatus5.1 ViscometerA Saybolt Furol viscometer conforming tothe requirements specified in Test Method D88.5.2 SieveA 850-m sieve or a 20-mesh strainer of wirecloth, framed or

11、unframed. Refer to Specification E11.5.3 ThermometersASTM No. 17C or 17F for tests at25C (77F) and ASTM No. 19C or 19F for tests at 50C(122F), conforming to the requirements of Specification E1,or any other thermometric device of equal accuracy.5.4 Water Bath or Oven, capable of maintaining the requ

12、iredtesting temperature within the limits specified in Table 2 ofTest Method D88.5.5 Receiving Flask, as shown in Test Method D88.6. Hazards6.1 WarningMercury has been designated by EPA andmany state agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Merc

13、ury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website(www.epa.gov/mercury/faq.htm) for additional information.1Th

14、is test method is under the jurisdiction of ASTM Committee D04 on Roadand Paving Materials and is the direct responsibility of Subcommittee D04.42 onEmulsified Asphalt Test.Current edition approved June 1, 2009. Published June 2009.2For referenced ASTM standards, visit the ASTM website, www.astm.org

15、, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Users should b

16、e aware that selling mercury or mercurycontaining products (or both) into your state may be prohibitedby state law.7. Procedure7.1 Tests at 25C (77F)Clean and dry the viscometer andinsert the stopper or cork. Follow either Procedure A or Bbelow:7.1.1 Procedure APour approximately 100 mL of theemulsi

17、fied asphalt into a 400 mL glass beaker. Immerse bottomof the beaker containing the emulsified asphalt approximately50 mm (2 in.) below the level of a 25C (77F) water bath.Hold the beaker upright and stir the emulsified asphalt with awide circular motion at a rate of 60 revolutions per minute withth

18、e thermometric device to obtain uniform temperature distri-bution. Avoid incorporation of bubbles. Pour the sample intothe viscometer through the 850-m sieve or 20-mesh straineruntil it is above the overflow rim. Stir the emulsified asphalt inthe viscometer with the thermometric device, avoiding bub

19、bleformation. Adjust the viscometer bath temperature until theemulsified asphalt temperature remains constant for 1 minute at25 6 0.1C (77 6 0.2F). Withdraw the thermometric device.Quickly remove the excess emulsified asphalt from the gallerywith a suction pipet or a vacuum hose. Determine the visco

20、sityas described in Test Method D88. Report the results to thenearest full second.7.1.2 Procedure BPour the sample of emulsified asphaltinto an appropriately sized (approximately 120 mL) bottle.Place the sealed bottle into a water bath maintained at 25C(77F) for 30 minutes. Remove the bottle from th

21、e bath andmix the sample by inverting the bottle several times slowlyenough to avoid bubble formation. Pour the sample into theviscometer through the 850-mm sieve or 20-mesh strainer untilit is above the overflow rim. Stir the emulsified asphalt in theviscometer with the thermometric device, avoidin

22、g bubbleformation. Adjust the viscometer bath temperature until theemulsified asphalt temperature remains constant for 1 minute at25 6 0.1C (77 6 0.2F). Withdraw the thermometric device.Quickly remove the excess emulsified asphalt from the gallerywith a suction pipet or a vacuum hose. Determine the

23、viscosityas described in Test Method D88. Report the results to thenearest full second.7.2 Tests at 50C (122F)Clean and dry the viscometerand insert the stopper or cork. Follow either Procedure A or Bbelow:7.2.1 Procedure AIf the sample of emulsified asphalt iscooler than 50C (122F), heat the sample

24、 to 50 6 3C (122 65F) in a 71 6 3C (160 6 5F) water bath or oven. Stir thesample thoroughly without incorporating bubbles, and thenpour approximately 100 mL into a 400-mL glass beaker.Immerse the bottom of the beaker containing the emulsifiedasphalt approximately 50 mm (2 in.) below the level of a 7

25、1 63C (160 6 5F) water bath. Hold the beaker upright and stirthe emulsified asphalt with a wide circular motion at a rate of60 revolutions per minute with the thermometric device toobtain uniform temperature distribution. Avoid incorporationof bubbles. Heat the emulsified asphalt in the water bath t

26、o 51.46 0.3C (124.5 6 0.5F). Immediately pour the emulsifiedasphalt through the 850-m sieve or 20-mesh strainer into theviscometer until it is above the overflow rim. Stir the emulsi-fied asphalt in the viscometer at 60 revolutions per minute withthe thermometric device, avoiding bubble formation. A

27、djustthe bath temperature until the emulsified asphalt temperatureremains constant for 1 minute at 50 6 0.1C (122 6 0.2F).Withdraw the thermometric device. Quickly remove the excessemulsified asphalt from the gallery with a suction pipet or avacuum hose. Determine the viscosity as described in TestM

28、ethod D88. Report the results to the nearest full second.7.2.2 Procedure BPour the sample of emulsified asphaltinto an appropriately sized (approximately 120 mL) bottle.Place the sealed bottle into a water bath or oven maintained at51.4 6 0.3C (124.5 6 0.5F) for 30 minutes. Remove thebottle from the

29、 bath or oven and mix the sample by invertingthe bottle several times slowly enough to avoid bubble forma-tion. Pour the sample into the viscometer through the 850-mmsieve or 20-mesh strainer until it is above the overflow rim. Stirthe emulsified asphalt in the viscometer at 60 revolutions perminute

30、 with the thermometric device, avoiding bubble forma-tion. Adjust the bath temperature until the emulsified asphalttemperature remains constant for 1 minute at 50 6 0.1C (1226 0.2F). Withdraw the thermometric device. Quickly removethe excess emulsified asphalt from the gallery with a suctionpipet or

31、 a vacuum hose. Determine the viscosity as described inTest Method D88. Report the results to the nearest full second.NOTE 2While the Saybolt Furol viscometer is not used for petroleumproducts and lubricants when the time of flow is less than 25 s, thisinstrument is satisfactory for testing emulsifi

32、ed asphalt when the time offlow is not less than 20 s.8. Precision and Bias8.1 The following criteria should be used for judging theacceptability of results (95 % probability).8.1.1 Duplicate results by the same operator should not beconsidered suspect unless they differ by more than the follow-ing

33、amount:Test Temperature,C (F)Viscosity,sRepeatability,% of the mean25 (77) 20 to 100 550 (122) 75 to 400 9.68.1.2 The results submitted by each of two laboratoriesshould not be considered suspect unless they differ by morethan the following amount:Test Temperature,C (F)Viscosity,sReproducibility,% o

34、f the mean25 (77) 20 to 100 1550 (122) 75 to 400 219. Keywords9.1 asphalt; emulsified asphalt; emulsion; furol; saybolt;viscosityD7496092ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this sta

35、ndard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years an

36、dif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee,

37、which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or serviceastm.org (e-mail); or through the ASTM website(www.astm.org).D7496093