1、Designation: E2568 17aStandard Specification forPB Exterior Insulation and Finish Systems1This standard is issued under the fixed designation E2568; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe

2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers PB Exterior Insulation andFinish Systems (EIFS) defined as an exterior, non-bearing wallcovering providing a weath

3、er-resistant exterior wall envelopeon walls required to be combustible or noncombustible, fire-resistance-rated or nonfire-resistance-rated. Further, PB EIFSis a system described as being applied over expanded polysty-rene or polyisocyanurate insulation board, an adhesive ormechanical attachment of

4、the insulation board to a substrate, orboth, glass fiber reinforcing mesh, a base coat on the face of theinsulation board, and a textured protective finish coat.1.2 This specification does not cover Class PB EIFS withdrainage.1.3 This specification qualifies EIFS products for use innormal service co

5、nditions and is not for evaluating in serviceEIFS installations.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard doe

6、s not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Stan

7、dards:2B117 Practice for Operating Salt Spray (Fog) ApparatusC297/C297M Test Method for Flatwise Tensile Strength ofSandwich ConstructionsC578 Specification for Rigid, Cellular Polystyrene ThermalInsulationC1289 Specification for Faced Rigid Cellular Polyisocyanu-rate Thermal Insulation BoardD2247 P

8、ractice for Testing Water Resistance of Coatings in100 % Relative HumidityE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE119 Test Methods for Fire Tests of Building Constructionand MaterialsE330/E330M Test Method for Structural Performance ofExterior Windows, Doors, Skyligh

9、ts and Curtain Walls byUniform Static Air Pressure DifferenceE331 Test Method for Water Penetration of ExteriorWindows, Skylights, Doors, and Curtain Walls by Uni-form Static Air Pressure DifferenceE2098/E2098M Test Method for Determining TensileBreaking Strength of Glass Fiber Reinforcing Mesh forU

10、se in Class PB Exterior Insulation and Finish Systems(EIFS), after Exposure to a Sodium Hydroxide SolutionE2110 Terminology for Exterior Insulation and Finish Sys-tems (EIFS)E2134/E2134M Test Method for Evaluating the Tensile-Adhesion Performance of an Exterior Insulation andFinish System (EIFS)E248

11、5/E2485M Test Method for Freeze/Thaw Resistance ofExterior Insulation and Finish Systems (EIFS) and WaterResistive Barrier CoatingsE2486/E2486M Test Method for Impact Resistance of ClassPB and PI Exterior Insulation and Finish Systems (EIFS)G23 Practice for Operating Light-Exposure Apparatus(Carbon-

12、Arc Type) With and Without Water for Exposureof Nonmetallic Materials (Withdrawn 2000)3G26 Practice for Operating Light-Exposure Apparatus(Xenon-Arc Type) With and Without Water for Exposureof Nonmetallic Materials (Discontinued 2001) (With-drawn 2000)3G153 Practice for Operating Enclosed Carbon Arc

13、 LightApparatus for Exposure of Nonmetallic MaterialsG155 Practice for Operating Xenon Arc Light Apparatus forExposure of Non-Metallic Materials1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.58on Ext

14、erior Insulation and Finish Systems (EIFS).Current edition approved March 1, 2017. Published March 2017. Originallyapproved in 2007. Last previous edition approved in 2017 as E2568-17. DOI:10.1520/E2568-17A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer

15、 Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West

16、 Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Tra

17、de Organization Technical Barriers to Trade (TBT) Committee.12.2 NFPA Standards:4ANSI/NFPA 268 Standard Test Method for DeterminingIgnitability of Exterior Wall Assemblies Using a RadiantHeat Energy SourceANSI/NFPA 285 Standard Fire Test Method for the Evalu-ation of Fire Propagation Characteristics

18、 of Exterior,Nonload-bearing Wall Assemblies Containing Combus-tible Components3. Terminology3.1 Definitions are in accordance with Terminology E2110unless otherwise specified.3.2 Definitions of Terms Specific to This Standard:3.2.1 class PB EIFS, nEIFS where the base coat varies inthickness dependi

19、ng upon the number of layers, or thickness ofreinforcing mesh. The reinforcing mesh is glass fiber mesh thatis encapsulated by the base coat in accordance with EIFSmanufacturer recommendations. Protective finish coats, ofvarious thicknesses in a variety of textures and colors, areapplied over the ba

20、se coat.3.2.1.1 DiscussionClass PB EIFS includes foam plasticconforming to either Specifications C578 or C1289.3.2.2 EIFS-related construction, nconstruction that worksin conjunction with the EIFS, but is not part of the EIFS.4. Materials and Manufacture4.1 Product DescriptionThe material and specif

21、icationsshall be as specified by the selected EIFS manufacturer andshall be defined as in Terminology E2110 except as modifiedherein.5. Performance Requirements5.1 The system and its components shall meet or exceed theperformance standards described in 5.2 5.7 of this specifica-tion.5.2 Performance:

22、5.2.1 System performance shall be in conformance with theminimum properties listed in Table 1.5.3 Component performance shall be in conformance withTable 2.5.4 Fire Performance:5.4.1 System fire performance shall be in conformance withTable 3 as required.5.5 Component fire performance shall be in ac

23、cordance withTable 4.5.6 Structural performance shall be in conformance withTable 5.5.7 Impact shall be in conformance with Table 6.6. Inspection6.1 Materials supplied by the manufacturer shall be suppliedto the site location in original unopened containers with labelsintact. Upon arrival, the mater

24、ials shall be inspected fordamage, and the manufacturer notified of any discrepancies.Unsatisfactory materials shall not be used.7. Packaging and Package Marking7.1 A description of the method of packaging and fieldidentification of the material shall include the following:7.1.1 Name and address of

25、the manufacturer.7.1.2 Identification of components,7.1.3 Lot or batch number,7.1.4 Quantity of material in the packaged mix,7.1.5 Storage instructions,7.1.6 Pot life,7.1.7 Expiration date (when applicable), and7.1.8 The name of the accredited inspection agency (whenapplicable).8. Keywords8.1 adhesi

26、ve; basecoat; Class PB; EIFS; Exterior Insulationand Finish System; system; textured finish; thermal insulationboard4Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.nfpa.org.TABLE 1 System Performance TestsCharacteristic Standard Minim

27、um PropertiesAccelerated weathering Practices G153Aor G155B,CNo deleterious effectsDafter 2000 h when viewed under 5 magnification.Freeze/thaw Test Method E2485/E2485M(Formerly EIMA Std. 101.01)No deleterious effectsDwhen viewed under 5 magnification.Salt spray resistance Practice B117 No deleteriou

28、s effectsDat 300-h exposure period.Tensile bond adhesion Test Methods E2134/E2134M or C297/C297MNo failure in the adhesive coat, base coat, or finish coat. The insulationboard shall fail cohesively except that 25 % adhesive failure is acceptable.For tested values of 15 psi (103 kPa) or greater, adhe

29、sive failure up to100 % is acceptable.Water penetration Test Method E331 The exterior wall envelope design shall be considered to resist wind-drivenrain where the results of testing indicate that water did not penetratecontrol joints in the exterior wall envelope, joints at the perimeter of openings

30、or intersections of terminations with dissimilar materials after 2 h of waterapplication at a pressure differential of 6.24 psf (299 Pa).Water resistance Practice D2247 No deleterious effectsDat 14-day exposure.AFormerly specified in Practice G23.BFormerly specified in Practice G26.CDue to differenc

31、es in spectral power distribution, results from Practice G155, Cycle 1, and Practice G153, Cycle 1, cannot be directly compared.DNo deleterious effects; no cracking, checking, crazing, erosion, rusting, blistering, peeling, or delamination.E2568 17a2ASTM International takes no position respecting th

32、e validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard i

33、s subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International He

34、adquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This s

35、tandard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585 (phone), 610-832-9555 (fax), or

36、 serviceastm.org (e-mail); or through the ASTM website(www.astm.org). Permission rights to photocopy the standard may also be secured from the Copyright Clearance Center, 222Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http:/ 2 Component Performance TestsCharacteristic Standard Minimum Pr

37、opertiesPhysical properties and requirements for EPS Specification C578 Meets Type IPhysical properties and requirements for polyisocyanurate Specification C1289 Meets Type II, Class 2 or 3Alkali resistance of reinforcing mesh Test Method E2098/E2098M 120 pli (21 N/mm) retained tensile strengthTABLE

38、 3 System Fire Performance TestsCharacteristic Test Method Minimum PropertiesFire endurance Test Methods E119 Maintain fire resistance of known, rated wall assemblyFull-scale multi-story fire test ANSI/NFPA 285 1. Resistance to vertical spread of flame within the core of the panel fromone story to t

39、he next.2. Resistance to flame propagation over the exterior face of the system.3. Resistance to vertical spread of flame over the interior (room side)surface from one story to the next.4. Resistance to lateral spread of flame from the compartment of fireorigin to adjacent spacesIgnition resistance

40、ANSI/NFPA 268 No surface ignition when exposed to 3950 BTU-h/ft2(12.5 kW/m2).TABLE 4 Fire Performance TestCharacteristic Test Method Minimum PropertiesSurface burning Test Method E84 Insulation board and reinforced coating system components shall betested separately and have a flame spread of 25 or

41、less, and smokedeveloped of 450 or less.AAWhen used as part of an engineering analysis for system fire performance, additional testing of combined components may be required at the direction of the qualifiedprofessional performing the analysis.TABLE 5 Structural Performance TestsCharacteristic Test

42、Method Minimum PropertiesWind load Test Method E330/E330M Report negative and positive wind load valuesTABLE 6 Impact Performance TestsNOTE 1The lowest value stated for each level is the minimum value required.Characteristic Test Method Minimum PropertiesImpact resistance Test Method E2486/E2486MStandard: 25-49 in-lb (2.83-5.54J)Medium: 50-89 in-lb (5.65-10.1J)High: 90-150 in-lb (10.2-17J)Ultra High: 150 in-lb (17J)E2568 17a3