1、BRITISH STANDARD BS 7001:1988 Incorporating Amendment No. 1 and implementing Amendments Nos. 2 and 3 not published separately Specification for Interchangeability and safety of a standardized luminaire supporting coupler ICS 29.120.30; 29.140.40BS7001:1988 This British Standard, having been prepared
2、 under the directionof the Power ElectricalEngineering StandardsCommittee, was published underthe authority ofthe BoardofBSI and comes into effect on 30 June 1988 BSI 04-1999 The following BSI references relate to the work on this standard: Committee reference PEL/4 Draft for comment 86/24102 DC ISB
3、N 0 580 16603 1 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Power Electrical Engineering Standards Committee (PEL/-) to Technical Committee PEL/4, upon which the following bodies were represented: ASTA Certification Services Associat
4、ion of Consulting Engineers Association of Control Manufacturers TACMA (BEAMA Ltd.) Association of Manufacturers of Domestic Electrical Appliances British Electrical Systems Association (BEAMA Ltd.) British Electrotechnical Approvals Board British Plastics Federation Consumer Policy Committee of BSI
5、 Decorative Lighting Association Department of Health and Social Security Department of Trade and Industry (Consumer Safety Unit, CA Division) ERA Technology Ltd. Electrical Contractors Association Electrical Installation Equipment Manufacturers Association (BEAMA Ltd.) Electrical Power Engineers As
6、sociation Electricity Supply Industry in England and Wales Institution of Electrical Engineers Lighting Industry Federation Ltd. National Inspection Council for Electrical Installation Contracting Amendments issued since publication Amd. No. Date of issue Comments 7625 June 1993 9295 December 1996 9
7、764 May 1998 Indicated by a sideline in the marginBS7001:1988 BSI 04-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 General and particular requirements 1 3 Rated current 1 4 Load supporting capacities 1 5 Dimensions 1 6 Marking 1 Figure 1 LCS plug interface de
8、tail 2 Figure 2 Integral LSC plug and component LSC plug 3 Figure 3 Maximum permissible profile for terminal housing and cord restraint for independent LSC plug 4 Figure 4 LSC outlet interface detail 5 Figure 5 LSC outlet for wall mounting 6 Figure 6 LSC outlet for ceiling mounting 7 Figure 7 LSC ou
9、tlet for ceiling mounting. Cover fixing details and minimum space for independent LSC plug 8 Figure 8 LSC outlet wall mounting box 9 Figure 9 Panel mounted 4 pin LSC socket 10 Figure 10 4 pin socket LSC outlet for ceiling mounting 11 Figure 11 4 pin socket LSC outlet for 1 gang flushplate 12 Figure
10、12 4 pin LSC plug interface detail 13 Figure 13 4 pin integral LSC plug and component LSC plug 14 Figure 14 4 pin LSC outlet interface detail 15 Figure 15 4 pin socket LSC outlet 16 Publications referred to Inside back coverBS 7001:1988 ii BSI 04-1999 Foreword This British Standard has been prepared
11、 under the direction of the Power Electrical Engineering Standards Committee. The growing use of luminaire supporting couplers in place of ceiling roses led to a request for standards to ensure the safety and interchangeability of such accessories. This standard has been based on drafts submitted by
12、 the Decorative Lighting Association and the Electrical Installation Equipment Manufacturers Association, and gives requirements for the interchangeability and safety of a standardized luminaire supporting coupler. The general requirements are specified in a separate standard, BS6972. A British Stan
13、dard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover,
14、 an inside front cover, pagesi andii, pages1 to16, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.BS7001:1988 BSI 04-1999 1 1 Scope This Britis
15、h Standard specifies dimensions and particular requirements for the interchangeability and safety of a standardized luminaire supporting coupler (LSC) comprising an LSC plug and an LSC outlet. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Gene
16、ral and particular requirements LSC plugs and LSC outlets as referred to in this standard shall be capable of complying with all the relevant requirements specified in BS6972 except that the rated current shall be as specified in clause3 and the load supporting capacity shall be as specified in clau
17、se4. The dimensions shall be as specified in clause5. Marking shall be as specified in clause6. 3 Rated current LSC outlets and rewireable independent LSC plugs and component LSC plugs shall have a rated current of 6 A. Integral LSC plugs shall have a ratedcurrent not less than the maximum current o
18、fthe luminaire, or 1 A, whichever is the greater. Non-rewireable independent plugs shall have a rated current appropriate to the flexible cord fitted by the manufacturer (see also clause 6 of BS6972:1988). 4 Load supporting capacities LSC outlets and LSC plugs, when assembled together, shall be capa
19、ble of sustaining the load of luminaires as follows: a) by flexible cord: 5 kg; b) by direct support from a horizontal surface:5kg; c) by direct support from a vertical surface: a load of2.5kg producing a turning moment of1.5Nm. 4.1 Compliance shall be checked by inspection and by one of the tests d
20、escribed in 22.6, 22.7 or 22.8 of BS6972:1988. 5 Dimensions Luminaire supporting couplers shall have the dimensions shown in Figure 1 to Figure 15 inclusive. 5.1 Compliance shall be checked by measurement (see also clause 9 of BS6972:1988). 6 Marking Marking shall be as specified in clause 8 of BS69
21、72:1988, except that instead of the marking specified in 8.1 b) and 8.2 b) of BS6972:1988, the number of this British Standard, i.e. BS7001 1) , shall be marked. 1) Marking BS 7001 on or in relation to a product represents a manufacturers declaration of conformity, i.e. a claim by or on behalf of th
22、e manufacturer that the product meets the requirements of the standard. The accuracy of the claim is therefore solely the responsibility of the person making the claim. Such a declaration is not to be confused with third party certification of conformity, which may also be desirable.BS 7001:1988 2 B
23、SI 04-1999 All linear dimensions are in millimetres. Figure 1 LSC plug interface detailBS7001:1988 BSI 04-1999 3 NOTE 1All or part of the plug may be a constructional part of the luminaire. NOTE 2See Figure 1 for plug interface details. This drawing does not purport to show constructional details. A
24、ll linear dimensions are in millimetres. Figure 2 Integral LSC plug and component LSC plugBS 7001:1988 4 BSI 04-1999 NOTESee Figure 1 for plug interface details. See Figure 2 for plug profile details. This drawing does not purport to show constructional details. Linear dimension is in millimetres. F
25、igure 3 Maximum permissible profile for terminal housing and cord restraint for independent LSC plugBS7001:1988 BSI 04-1999 5 All linear dimensions are in millimetres. Figure 4 LSC outlet interface detailBS 7001:1988 6 BSI 04-1999 NOTESee Figure 4 for outlet interface details. This drawing does not
26、purport to show constructional details. All linear dimensions are in millimetres. Figure 5 LSC outlet for wall mountingBS 7001:1988 BSI 04-1999 7 NOTESee Figure 4 for interface detail for outlet. For front protrusion dimensions see Figure 5. This drawing does not purport to show constructional detai
27、ls. All linear dimensions are in millimetres. Figure 6 LSC outlet for ceiling mountingBS 7001:1988 8 BSI 04-1999 This drawing does not purport to show constructional details. All linear dimensions are in millimetres. Figure 7 LSC outlet for ceiling mounting. Cover fixing details and minimum space fo
28、r independent LSC plugBS7001:1988 BSI 04-1999 9 All dimensions are in millimetres. Figure 8 LSC outlet wall mounting boxBS 7001:1988 10 BSI 04-1999 NOTESee Figure 4, Figure 14 and Figure 15 for interface details (wall mounting box not applicable). For other details see Figure 5. This drawing does no
29、t purport to show constructional details. All dimensions are in millimetres. Figure 9 Panel mounted 4 pin LSC socketBS7001:1988 BSI 04-1999 11 NOTESee Figure 4, Figure 14 and Figure 15 for interface details. For other details see Figure 5 and Figure 6. This drawing does not purport to show construct
30、ional details. Figure 10 4 pin socket LSC outlet for ceiling mountingBS 7001:1988 12 BSI 04-1999 NOTESee Figure 4, Figure 14 and Figure 15 for interface details. For other details see Figure 5. This drawing does not purport to show constructional details. All linear dimensions are in millimetres. Fi
31、gure 11 4 pin socket LSC outlet for 1 gang flushplateBS7001:1988 BSI 04-1999 13 Figure 12 4 pin LSC plug interface detailBS 7001:1988 14 BSI 04-1999 Figure 13 4 pin integral LSC plug and component LSC plugBS7001:1988 BSI 04-1999 15 Figure 14 4 pin LSC outlet interface detailBS 7001:1988 16 BSI 04-19
32、99 NOTESee Figure 4 and Figure 14 for remaining interface details. For other details see Figure 5. This drawing does not purport to snow constructional details All dimensions are in millimetres. Figure 15 4 pin socket LSC outletBS7001:1988 BSI 04-1999 Publications referred to BS 31, Steel conduit an
33、d fittings for electrical wiring. BS 3643, ISO metric screw threads. BS 3643-2, Specification for selected limits of size. BS 6972, Specification for general requirements for luminaire supporting couplers for domestic, light industrial and commercial use. BS 7001:1988 BSI 389 Chiswick High Road Lond
34、on W4 4AL BSIBritishStandardsInstitution BSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions BritishStandards are updated by amendment or revisio
35、n. Users of BritishStandards should make sure that they possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this BritishStandard would inform the Se
36、cretary of the technical committee responsible, the identity of which can be found on the inside front cover. Tel:02089969000. Fax:02089967400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying
37、standards Orders for all BSI, international and foreign standards publications should be addressed to Customer Services. Tel:02089969001. Fax:02089967001. In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published as British
38、Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give detail
39、s on all its products and services. Contact the Information Centre. Tel:02089967111. Fax:02089967048. Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details of these and other benefits contact Membe
40、rship Administration. Tel:02089967002. Fax:02089967001. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the internationalstandardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may
41、be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, an
42、d size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. If permission is granted, the terms may include royalty payments or a licensing agreement. Details and advice can be obtained from the Copyright Manager. Tel:02089967070.