1、BS 8441-2:2006Health informatics Medical digital imaging profiles Part 2: “M-IHE6-4.8MIS-CT” CT images storedICS 35.240.80NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDLicensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSIP
2、ublishing and copyright informationThe BSI copyright notice displayed in this document indicates when the document was last issued. BSI 2006ISBN 0 580 49046 7The following BSI references relate to the work on this standard:Committee reference IST/35Draft for comment 03/107682 CDPublication historyFi
3、rst published, September 2006Amendments issued since publicationAmd. no. Date Text affectedBS 8441-2:2006Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 2006 iBS 8441-2:2006ContentsForeword iiIntroduction 11 Scope 12 Normative references 13 Terms and d
4、efinitions 14 Abbreviations 25 Conformance 26 MDI profile 2AnnexesAnnex A (informative) Column headers for the profile definition table 12Bibliography 13List of tablesTable 1 Profile table M-IHE6.0-II-4-4.8MIS-CT 3Table 2 Additional requirements table 11Table 3 Clarification table 11Summary of pages
5、This document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 13 and a back cover.Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSIBS 8441-2:2006ii BSI 2006ForewordPublishing informationThis British Standard was published by BSI an
6、d came into effect on 4 September 2006. It was prepared by Technical Committee IST/35, Health informatics, in accordance with the provisions of BS 8440. A list of organizations represented on this committee can be obtained on request to its secretary.Contractual and legal considerationsThis publicat
7、ion does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI B
8、SI 2006 1BS 8441-2:2006IntroductionThe Integrating the Healthcare Enterprise (IHE) Technical Framework document provides a scenario, as required by BS 8440-2, and a set of profiles expressed as tables and text to enable the smooth implementation of information technology in support of a set of caref
9、ully defined basic clinical tasks associated with diagnostic imaging. This medical digital imaging (MDI) profile specifies the content of the IHE Technical Framework document regarding metadata contained in the IHE Patient Registration Transaction in a concise form that can be expressed as printed t
10、ables or in electronic form. The electronic form enables electronic comparison with product profiles available in electronic form.1 ScopeThis British Standard specifies the metadata to be included in the Modality Images Stored transaction as specified in the IHE Technical Framework Volume II, Revisi
11、on 6.0, section 4.8 and Appendix A, when applied to a computed tomography (CT) image data set.It falls within the taxonomy class of Management (see BS 8440-1).The relevant scenario included in IHE Technical Framework Volume II, Revision 6.0, section 4.8, concerns the transmission of any image from a
12、n image acquisition system to an information system, while Appendix A specifies the appropriate use of required data elements.2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For un
13、dated references, the latest edition of the referenced document (including any amendments) applies.ANSI/HL7 Version 2.3.1 1998 (HL7 v2.3.1), ANSI Application Protocol of Electronic Data Exchange in Healthcare EnvironmentsIHE Technical Framework Volume II, Revision 6.0 (IHE6-0) ACC/HIMSS/RSNA, May 18
14、, 2005ISO 12052, Digital imaging DICOM Communication, workflow and data management3 Terms and definitionsFor the purposes of this standard, the terms and definitions given in BS 8440-1 and BS 8440-2 apply. (See also Annex A.)Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontroll
15、ed Copy, (c) BSIBS 8441-2:20062 BSI 20064Abbreviations5Conformance Conformance of a product with the MDI metadata profile specified in this British Standard shall be tested by determining that the patient registration communication metadata within a relevant message type (see 6.3) includes all the M
16、DI profile data elements specified in the profile tables (Table 1, Table 2 and Table 3).NOTE 1 Conformance of a product with the scenario is beyond the scope of this British Standard.Applications shall make available all the content items included in the profile table with optionality R (required),
17、optionality C (conditional), if the appropriate condition is met, and optionality RE if a value for the data item is known. NOTE 2 Applications are expected to conform to the requirements of IHE6.6 MDI profile 6.1 Identification6.1.1 Name: IHE Technical Framework 6.0-II-4 4.8 Modality ImagesStored -
18、 CT6.1.2 ID: M-IHE6.0-II-4-4.8MIS-CT6.1.3 OID: 1.2.826.0.1002.102.8441.26.2 Base scenario documentIHE Technical Framework Volume II Revision 6.0.NOTE IHE6 specifies a set of profiles of DICOM provisions.6.3 Message typeStore CT Image.A/C Additional requirement/ClarificationCard CardinalityCT Compute
19、d tomographyDICOM ISO 12052, Digital imaging DICOM Communication, workflow and data managementHL7 2.3.1 Health Level 7 Version 2.3.1 ID IdentifierIHE6 IHE Technical Framework Revision 6.0MDI Medical digital imagingOID Object identifierLicensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006,
20、Uncontrolled Copy, (c) BSI BSI 2006 3BS 8441-2:2006Table1Profile table M-IHE6.0-II-4-4.8MIS-CTProfile item IDStd./ Ver.Container nameContent item nameContent item ID LENDTCardOptExample valueDoc. clauseA/COIDM-IHE6.0-II-4- 4.8MIS-CT.1DICOM PatientPatients Name(0010,0010)64PN11RE JohnsonEdna1.2.826.0
21、.1002.102.8441.2.1M-IHE6.0-II-4- 4.8MIS-CT.2DICOM PatientPatient ID (0010,0020)64LO11RE H015640951.2.826.0.1002.102.8441.2.2M-IHE6.0-II-4- 4.8MIS-CT.3DICOM PatientPatients Birth Date (0010,0030)8DA1.1RE 191710231.2.826.0.1002.102.8441.2.3M-IHE6.0-II-4- 4.8MIS-CT.4DICOM PatientPatients Sex (0010,0040
22、)16CS11RE F1.2.826.0.1002.102.8441.2.4M-IHE6.0-II-4- 4.8MIS-CT.5DICOM General StudyStudy Instance UID (0020,000D)64UI11R 1.2.826.0.1.3680043.2.587.6678971.2.826.0.1002.102.8441.2.5M-IHE6.0-II-4- 4.8MIS-CT.6DICOM General StudyStudyDate (0008,0020)8DA1.1RE 200301151.2.826.0.1002.102.8441.2.6M-IHE6.0-I
23、I-4- 4.8MIS-CT.7DICOM General StudyStudyTime(0008,0030)16TM11RE 1205141.2.826.0.1002.102.8441.2.7M-IHE6.0-II-4- 4.8MIS-CT.8DICOM General StudyReferring Physicians Name(0008,0090)64PN11RE BrownFrederick1.2.826.0.1002.102.8441.2.8M-IHE6.0-II-4- 4.8MIS-CT.9DICOM General StudyPerson Identification CodeS
24、equence(0040,1101)SQ11R1.2.826.0.1002.102.8441.2.9M-IHE6.0-II-4- 4.8MIS-CT.10DICOM Person ID Code SequenceCode Value(0008,0100)16SH11RXY123451.2.826.0.1002.102.8441.2.10Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI4 BSI 2006BS 8441-2:2006Table1Profile ta
25、ble M-IHE6.0-II-4-4.8MIS-CT (continued)Profile item IDStd./ Ver.Container nameContent item nameContent item ID LENDTCardOptExample valueDoc. clauseA/COIDM-IHE6.0-II-4- 4.8MIS-CT.11DICOM Person ID CodeSequenceCoding Scheme Designator(0008,0102)16SH11RUKNHS171.2.826.0.1002.102.8441.2.11M-IHE6.0-II-4-
26、4.8MIS-CT.12DICOM Person ID CodeSequenceCoding Scheme Version(0008,0103)16SHR1.51.2.826.0.1002.102.8441.2.12M-IHE6.0-II-4- 4.8MIS-CT.13DICOM Person ID CodeSequenceCodeMeaning(0008,0104)64LO11RBrownFrederick1.2.826.0.1002.102.8441.2.13M-IHE6.0-II-4- 4.8MIS-CT.14DICOM General StudyStudyID (0020,0010)1
27、6SH11REM0300671.2.826.0.1002.102.8441.2.14M-IHE6.0-II-4- 4.8MIS-CT.15DICOMGeneralStudyAccessionNumber(0008,0050)16SH11REM030067-12431.2.826.0.1002.102.8441.2.15M-IHE6.0-II-4- 4.8MIS-CT.16DICOMGeneral StudyReferenced Study Sequence(0008,1110)SQ11R1.2.826.0.1002.102.8441.2.16M-IHE6.0-II-4- 4.8MIS-CT.1
28、7DICOMReferencedStudySequenceReferencedSOP Class UID(0008,1150)64UI11R1.2.840.10008.5.1.4.1.1.21.2.826.0.1002.102.8441.2.17M-IHE6.0-II-4- 4.8MIS-CT.18DICOMReferencedStudySequenceReferencedSOP Instance UID(0008,1155)64UI11R1.2.826.0.1.3680043.2.587.993401.2.826.0.1002.102.8441.2.18M-IHE6.0-II-4- 4.8M
29、IS-CT.19DICOM General StudyProcedure CodeSequence(0032,1064)SQ11R1.2.826.0.1002.102.8441.2.19M-IHE6.0-II-4- 4.8MIS-CT.20DICOM Procedure CodeSequenceCode Value(0008,0100)16SH11RCT12341.2.826.0.1002.102.8441.2.20Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BS
30、I BSI 2006 5BS 8441-2:2006Table1Profile table M-IHE6.0-II-4-4.8MIS-CT (continued)Profile item IDStd./ Ver.Container nameContent item nameContent item ID LENDTCardOptExample valueDoc.clauseA/COIDM-IHE6.0-II-4- 4.8MIS-CT.21DICOM Procedure CodeSequenceCoding Scheme Designator(0008,0102)16SH11ROPCS-41.2
31、.826.0.1002.102.8441.2.21M-IHE6.0-II-4- 4.8MIS-CT.22DICOM Procedure CodeSequenceCoding Scheme Version(0008,0103)16SH11R4.41.2.826.0.1002.102.8441.2.22M-IHE6.0-II-4- 4.8MIS-CT.23DICOM Procedure CodeSequenceCodeMeaning(0008,0104)64LO11RCT Chest with Contrast1.2.826.0.1002.102.8441.2.23M-IHE6.0-II-4- 4
32、.8MIS-CT.24DICOM General SeriesModality (0008,0060)16CS11RCT1.2.826.0.1002.102.8441.2.24M-IHE6.0-II-4- 4.8MIS-CT.25DICOM General SeriesSeries Instance UID (0020,000E)64UI11R1.2.826.0.1.3680043.2.587.66781.2.826.0.1002.102.8441.2.25M-IHE6.0-II-4- 4.8MIS-CT.26DICOM General SeriesSeries Number(0020,001
33、1)12IS11RE11.2.826.0.1002.102.8441.2.26M-IHE6.0-II-4- 4.8MIS-CT.27DICOM General SeriesProtocol Name(0018,1030)64LO11RThorax1.2.826.0.1002.102.8441.2.27M-IHE6.0-II-4- 4.8MIS-CT.28DICOM General SeriesPatient Position(0018,5100)16CS11REHFSPS3 C.7.3.1.1.21.2.826.0.1002.102.8441.2.28M-IHE6.0-II-4- 4.8MIS
34、-CT.29DICOM General SeriesRequestAttributes Sequence(0040,0275)SQ11R1.2.826.0.1002.102.8441.2.29M-IHE6.0-II-4- 4.8MIS-CT.30DICOMRequestAttributesSequenceRequested Procedure ID(0040,1001)16SH11RR1234561.2.826.0.1002.102.8441.2.30Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontr
35、olled Copy, (c) BSI6 BSI 2006BS 8441-2:2006Table1Profile table M-IHE6.0-II-4-4.8MIS-CT (continued)Profile item IDStd./ Ver.Container nameContentitemnameContent itemIDLENDTCardOptExample valueDoc.clauseA/COIDM-IHE6.0-II-4- 4.8MIS-CT.31DICOMRequestAttributesSequenceRequestedProcedureDescription(0032,1
36、060)64LO11RCT chest withcontrast1.2.826.0.1002.102.8441.2.31M-IHE6.0-II-4- 4.8MIS-CT.32DICOMRequestAttributesSequenceReason for Requested ProcedureCodeSequence(0040,100A)SQ11R1.2.826.0.1002.102.8441.2.32M-IHE6.0-II-4- 4.8MIS-CT.33DICOM Reason Code SequenceCode Value(0008,0100)16SH11RX1234567891.2.82
37、6.0.1002.102.8441.2.33M-IHE6.0-II-4- 4.8MIS-CT.34DICOM Reason Code SequenceCodingScheme Designator(0008,0102)16SH11RSNOMED-CT1.2.826.0.1002.102.8441.2.34M-IHE6.0-II-4- 4.8MIS-CT.35DICOM Reason Code SequenceCoding SchemeVersion(0008,0103)16SH11R3.51.2.826.0.1002.102.8441.2.35M-IHE6.0-II-4- 4.8MIS-CT.
38、36DICOM Reason Code SequenceCode Meaning(0008,0104)64LO11RDifficultyBreathing1.2.826.0.1002.102.8441.2.36M-IHE6.0-II-4- 4.8MIS-CT.37DICOMRequestAttributesSequenceScheduledProcedureStepID(0040,0009)16SH11R123456781.2.826.0.1002.102.8441.2.37M-IHE6.0-II-4- 4.8MIS-CT.38DICOMRequestAttributesSequenceSch
39、eduledProcedureDescription(0040,0007)64LO11RCT Chest with Contrast1.2.826.0.1002.102.8441.2.38M-IHE6.0-II-4- 4.8MIS-CT.39DICOMRequestAttributesSequenceScheduledProtocolCodeSequence(0040,0008)SQ11R1.2.826.0.1002.102.8441.2.39M-IHE6.0-II-4- 4.8MIS-CT.40DICOM SchedProtocolCodeSequenceCode Value(0008,01
40、00)16SH11RCT12341.2.826.0.1002.102.8441.2.40Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI BSI 2006 7BS 8441-2:2006Table1Profile table M-IHE6.0-II-4-4.8MIS-CT (continued)Profile item IDStd./ Ver.Container nameContentitemnameContent item ID LENDTCardOptExa
41、mple valueDoc.clauseA/COIDM-IHE6.0-II-4-4.8MIS- CT.41DICOM Sched Protocol CodeSequenceCoding SchemeDesignator(0008,0102)16SH11RSNOMED1.2.826.0.1002.102.8441.2.41M-IHE6.0-II-4-4.8MIS- CT.42DICOM Sched Protocol CodeSequenceCoding SchemeVersion(0008,0103)16SH11R3.51.2.826.0.1002.102.8441.2.42M-IHE6.0-I
42、I-4-4.8MIS- CT.43DICOM Sched Protocol CodeSequenceCodeMeaning(0008,0104)64LO11RCaLung1.2.826.0.1002.102.8441.2.43M-IHE6.0-II-4-4.8MIS- CT.44DICOM General SeriesPerformed Procedure StepID(0040,0253)16SH11R1234565781.2.826.0.1002.102.8441.2.44M-IHE6.0-II-4-4.8MIS- CT.45DICOM General SeriesPerformed Pr
43、ocedure StepStart Date(0040,0244)8DA11R200301151.2.826.0.1002.102.8441.2.45M-IHE6.0-II-4-4.8MIS- CT.46DICOM General SeriesPerformed Procedure StepStart Time(0040,0245)16TM11R1205141.2.826.0.1002.102.8441.2.46M-IHE6.0-II-4-4.8MIS- CT.47DICOM General SeriesPerformed Procedure Description(0040,0254)64L
44、O11RCT Chest with Contrast1.2.826.0.1002.102.8441.2.47M-IHE6.0-II-4-4.8MIS- CT.48DICOM General SeriesPerformed Protocol Code Sequence(0040,0260)SQ1NR1.2.826.0.1002.102.8441.2.48M-IHE6.0-II-4-4.8MIS- CT.49DICOM Performed Protocol CodeSequenceCodeValue(0008,0100)16SH11RCT12341.2.826.0.1002.102.8441.2.
45、49M-IHE6.0-II-4-4.8MIS- CT.50DICOM Performed Protocol CodeSequenceCoding SchemeDesignator(0008,0102)16SH11RSNOMED1.2.826.0.1002.102.8441.2.50Licensed Copy: Wang Bin, na, Thu Nov 02 07:16:41 GMT+00:00 2006, Uncontrolled Copy, (c) BSI8 BSI 2006BS 8441-2:2006Table1Profile table M-IHE6.0-II-4-4.8MIS-CT
46、(continued)Profile item IDStd./ Ver.Container nameContent item nameContent item ID LENDTCardOptExample valueDoc.clauseA/COIDM-IHE6.0-II-4- 4.8MIS-CT.51DICOM Performed ProtocolCodeSequenceCoding Scheme Version(0008,0103)16SH11R3.51.2.826.0.1002.102.8441.2.51M-IHE6.0-II-4- 4.8MIS-CT.52DICOM Performed
47、ProtocolCodeSequenceCodeMeaning(0008,0104)64LO11RCaLung1.2.826.0.1002.102.8441.2.52M-IHE6.0-II-4- 4.8MIS-CT.53DICOM Frameof ReferenceFrameofReference UID (0020,0052)64UI11R 1.2.826.0.1.3680043.2.587.90651.2.826.0.1002.102.8441.2.53M-IHE6.0-II-4- 4.8MIS-CT.54DICOM Frameof ReferencePositionReference I
48、ndicator(0020,1040)64LO11RESSNPS3C.7.4.1.1.21.2.826.0.1002.102.8441.2.54M-IHE6.0-II-4- 4.8MIS-CT.55DICOMGeneralEquipmentManufacturer (0008,0070)64LO11REGE1.2.826.0.1002.102.8441.2.55M-IHE6.0-II-4- 4.8MIS-CT.56DICOMGeneralImageImageNumber(0020,0013)12IS11RE11.2.826.0.1002.102.8441.2.56M-IHE6.0-II-4-
49、4.8MIS-CT.57DICOM General ImagePatient Orientation (0020,0020)16CS11RR,A1.2.826.0.1002.102.8441.2.57M-IHE6.0-II-4- 4.8MIS-CT.58DICOM General ImageImageDate (0008,0023)8DA11C200301151.2.826.0.1002.102.8441.2.58M-IHE6.0-II-4- 4.8MIS-CT.59DICOM General ImageImageTime(0008,0033)16TM11C1205141.2.826.0.1002.102.8441.2.59M-IHE6.0-II-4- 4.8MIS-CT.60DICOM Image PlanePixelSpacing (0028,0030)16DS11R0.10.11.2.8