BS EN 40-2-2004 Lighting columns - General requirements and dimensions《灯柱 一般要求和尺寸》.pdf
《BS EN 40-2-2004 Lighting columns - General requirements and dimensions《灯柱 一般要求和尺寸》.pdf》由会员分享,可在线阅读,更多相关《BS EN 40-2-2004 Lighting columns - General requirements and dimensions《灯柱 一般要求和尺寸》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 40-2:2004 Lighting columns Part 2: General requirements and dimensions The European Standard EN 40-2:2004 has the status of a British Standard ICS 93.080.40 BS EN 40-2:2004 This British Standard was published under the authority of the Standards Policy and Strategy Committee o
2、n 13 October 2004 BSI 13 October 2004 ISBN 0 580 44591 7 National foreword This British Standard is the official English language version of EN 40-2:2004. I t s u p e r s e d e s B S 5 6 4 9 - 2 : 1 9 7 8 wh i c h i s w i t hd r a wn . I t wi l l p a r t i a l l y s u pe r s e d e BS 5649-5 by amend
3、ment. The UK participation in its preparation was entrusted to Technical Committee B/509, Road equipment, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement interna
4、tional or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purpor
5、t to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee
6、any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 24, an
7、 inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN402 October2004 ICS93.080.40 SupersedesEN402:1976 Englishve
8、rsion LightingcolumnsPart2:Generalrequirementsanddimensions CandlabresdclairagepublicPartie2:Prescriptions gnralesetdimensions LichtmasteTeil2:AllgemeineAnforderungenundMae ThisEuropeanStandardwasapprovedbyCENon16August2004. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipula
9、tetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconcernings uchnational standardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French
10、,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariathasthesamestatusast heofficial versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,G
11、reece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Bru
12、ssels 2004CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN402:2004:EEN 40-2:2004 (E) 2 Contents page Foreword. 3 1 Scope 4 2 Normative references . 4 3 Terms and definitions. 4 4 Main dimensions. 5 4.1 Post top columns 5 4.2 Columns with brackets. 5
13、 4.3 Door openings and cable entry slots 8 4.3.1 Door openings. 8 4.3.2 Cable entry slots . 8 4.4 Base compartments and cableways .10 4.4.1 Compartment dimensions 10 4.4.2 Compartment door 10 4.4.3 Attachment of electrical equipment 10 4.4.4 Electrical cableways . 10 4.4.5 Protection category 10 4.4
14、.6 Earthing terminals. 13 4.5 Column planting depth and base plate. 13 4.5.1 Planting depth . 13 4.5.2 Base plate 13 4.6 Flange plates . 15 4.7 Connection dimensions for lanterns 16 4.7.1 General. 16 4.7.2 Post top lanterns. 17 4.7.3 Side entry lanterns 18 5 Tolerances . 19 5.1 Straightness 19 5.2 T
15、otal length of post top columns 20 5.3 Total length of columns with brackets . 20 5.4 Bracket projection. 21 5.5 Lantern fixing angle 21 5.6 Door opening and cable entry slot 21 5.7 Column cross-section 21 5.7.1 Metal columns . 21 5.7.2 Concrete columns. 21 5.8 Connection dimensions for lantern fixi
16、ng21 5.9 Twist in columns. 22 5.9.1 Columns with roots. 22 5.9.2 Columns with flange plates . 22 5.10 Thickness tolerance 22 5.11 Verticality tolerance 22 Annex A (informative) Passive safety 23 Bibliography . 24 EN 40-2:2004 (E) 3 Foreword This document (EN 40-2:2004) has been prepared by Technical
17、 Committee CEN/TC 50 “Lighting columns and spigots”, the secretariat of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by April 2005, and conflicting national standards shall b
18、e withdrawn at the latest by April 2005. This document supersedes EN 40-2:1976. This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. This Part gives the necessary requirements for specifiers and manufacturers of col
19、umns. The majority of lighting columns are made from steel, aluminium or concrete and are normally of a stepped tubular, round, octagonal or polygonal cross-section. They are usually of neutral design with a lantern spigot either at the post top or at the end of a bracket and are produced to certain
20、 standard dimensions and tolerances. This Part of EN 40 is the second in a series relating to specifications for lighting columns. When complete, EN 40 will consist of the following Parts: Part 1: Definitions and terms Part 2: Dimensions and tolerances Part 3: Design and verification 3-1 Specificati
21、on for characteristic loads 3-2 Verification by testing 3-3 Verification by calculation Part 5: Requirements for steel lighting columns Part 6: Requirements for aluminium lighting columns Part 7: Requirements for fibre reinforced polymer composite lighting columns According to the CEN/CENELEC Intern
22、al Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherl
23、ands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 40-2:2004 (E) 4 1 Scope This document specifies the requirements and dimensions for lighting columns, brackets, base compartments, cableways and earthing terminals. It applies to post top columns no
24、t exceeding 20 m height for post top lanterns and columns with brackets not exceeding 18 m height for side entry lanterns. This Part does not attempt to restrict the actual appearance or shape of the column or bracket. The majority of lighting columns are normally of a stepped tubular, round, octago
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
本资源只提供5页预览,全部文档请下载后查看!喜欢就下载吧,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN4022004LIGHTINGCOLUMNSGENERALREQUIREMENTSANDDIMENSIONS 灯柱 一般 要求 尺寸 PDF

链接地址:http://www.mydoc123.com/p-551224.html