1、Energy performance of buildings Method for calculation of system energy requirements and system efficienciesPart 5: Space heating and DHW storage systems (not cooling), Module M3-7, M8-7BS EN 15316-5:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06EUROPEAN STANDA
2、RD NORME EUROPENNE EUROPISCHE NORM EN 15316-5 May 2017 ICS 91.140.10; 91.140.65 English Version Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 5: Space heating and DHW storage systems (not cooling), Module M3-7, M8-7 Performance
3、nergtique des btiments - Mthode de calcul des besoins nergtiques et des rendements des systmes - Partie 5 : Systmes de stockage pour le chauffage et leau chaude sanitaire (sans refroidissement), Module M3-7, M8-7 Energetische Bewertung von Gebuden - Verfahren zur Berechnung der Energieanforderungen
4、und Nutzungsgrade der Anlagen - Teil 5: Raumheizung und Speicher fr erwrmtes Trinkwasser (keine Khlung), Modul M3-7, M8-7 This European Standard was approved by CEN on 27 February 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for givin
5、g this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three offic
6、ial versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of
7、Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia,
8、Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved world
9、wide for CEN national Members. Ref. No. EN 15316-5:2017 ENational forewordThis British Standard is the UK implementation of EN 15316-5:2017.The UK participation in its preparation was entrusted to Technical Committee RHE/24, Heating systems and water based cooling systems in buildings.A list of orga
10、nizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 20
11、17ISBN 978 0 580 87457 4ICS 91.140.65; 91.140.10Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 June 2017.Amendments/corrigenda issued since publicationDate T
12、ext affectedBRITISH STANDARDBS EN 15316-5:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15316-5 May 2017 ICS 91.140.10; 91.140.65 English Version Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 5: Space heating and DHW
13、storage systems (not cooling), Module M3-7, M8-7 Performance nergtique des btiments - Mthode de calcul des besoins nergtiques et des rendements des systmes - Partie 5 : Systmes de stockage pour le chauffage et leau chaude sanitaire (sans refroidissement), Module M3-7, M8-7 Energetische Bewertung von
14、 Gebuden - Verfahren zur Berechnung der Energieanforderungen und Nutzungsgrade der Anlagen - Teil 5: Raumheizung und Speicher fr erwrmtes Trinkwasser (keine Khlung), Modul M3-7, M8-7 This European Standard was approved by CEN on 27 February 2017. CEN members are bound to comply with the CEN/CENELEC
15、Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to
16、 any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the officia
17、l versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, No
18、rway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All right
19、s of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15316-5:2017 EBS EN 15316-5:2017EN 15316-5:2017 (E) 2 Contents Page European foreword . 5 Introduction 6 1 Scope 8 2 Normative references . 10 3 Terms and definitions 10 4 Symbols and abbreviation
20、s 11 4.1 Symbols 11 4.2 Subscripts 11 5 Description of the methods 11 5.1 Output of the method 11 5.2 Extension of the method 11 5.3 Technologies covered and schematisation of the hot water storage system . 12 5.4 Principles for hot water storage systems 13 6 Calculation of storage systems 14 6.1 Ou
21、tput data . 14 6.2 Calculation time steps 17 6.3 Input data 17 6.3.1 Source of data 17 6.3.2 Product data . 17 6.3.3 System design data 19 6.3.4 Control 19 6.3.5 Operating conditions 19 6.3.6 Constants and physical data . 20 6.4 Calculation procedure 21 6.4.1 Applicable time-step . 21 6.4.2 Operatin
22、g conditions calculation . 21 6.4.3 Energy calculation (storage modelled with multi volumes Method A) . 21 6.4.4 Simplified calculation procedure (storage modelled with a single volume Method B) 26 6.4.5 Thermal losses 28 6.4.6 Calculation of the auxiliary energy 28 6.4.7 Recoverable, recovered ther
23、mal losses . 28 7 Quality control 29 8 Compliance check. 29 Annex A (informative) Template for input data and choices 31 A.1 Model information . 31 A.2 Product description data . 31 A.2.1 Storage type 31 A.2.2 Type of energy use (services) 31 A.2.3 Storage fuel . 31 A.2.4 CE marking 32 BS EN 15316-5
24、:2017EN 15316-5:2017 (E) 3 A.2.5 Dimension . 32 A.2.6 Energy input/output . 32 A.2.7 Multiple energy input/output 33 A.2.8 Stand-by thermal losses . 33 A.2.9 Factors for energy recovery . 34 A.3 Design data . 35 A.3.1 Localization 35 A.3.2 Hydraulic connection 35 A.3.3 Storage control type 35 A.3.3.
25、1 Type of control 35 A.3.3.2 Adaptation of thermal losses for monthly or annual step time . 36 A.4 Operative conditions for method A hourly calculation time step . 36 A.5 Operative conditions for Method B - bin, monthly or annual calculation time step . 37 Annex B (informative) Default Input data 38
26、 B.1 Model information . 38 B.2 Product description data . 38 B.2.1 Storage type 38 B.2.2 Type of energy use (services) 38 B.2.3 Storage fuel . 38 B.2.4 CE marking 38 B.2.5 Dimension . 38 B.2.6 Energy input/output . 38 B.2.7 Multiple energy input/output 39 B.2.8 Stand-by thermal losses . 39 B.2.9 Fa
27、ctors for energy recovery . 41 B.3 Design data . 41 B.3.1 Localization 41 B.3.2 Hydraulic connection 41 B.3.3 Storage control type 41 B.3.3.1 Type of control 41 B.3.3.2 Adaptation of thermal losses for monthly or annual step time . 41 B.4 Operative conditions for method A hourly calculation time ste
28、p . 41 B.5 Operative conditions for Method B - bin, monthly or annual calculation time step 42 BS EN 15316-5:2017EN 15316-5:2017 (E) 4 Annex C (normative) Selection of methods . 43 C.1 Method A - Model based on a representation of stratified temperature in the storage . 43 C.1.1 Applicability of the
29、 stratified model . 43 C.1.2 Selection of the number of volumes to model the storage unit . 43 C.2 Method B - Model based on a representation of an homogenous temperature in the storage . 43 Annex D (informative) Alternative presentation for Method A 44 D.1 Step 2 - Direct withdrawal of a heat quant
30、ity (volume to withdraw) . 44 D.1.1 General . 44 D.1.2 Additional . 46 D.2 Step 3 - Temperature of the storage after volume withdrawal . 46 D.3 Step 6 - indirect heat input and output 47 D.4 Rearrange temperatures in the storage to a natural state 49 D.5 Heat exchanger - additional . 50 D.5.1 Genera
31、l . 50 D.5.2 Indirect heat input in the storage, using a solar collector loop. 50 D.5.3 Indirect heat output from the storage to the space heating service. . 51 Bibliography . 52 BS EN 15316-5:2017EN 15316-5:2017 (E) 5 European foreword This document (EN 15316-5:2017) has been prepared by Technical
32、Committee CEN/TC 228 “Heating systems and water based cooling systems in buildings”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2017 and conf
33、licting national standards shall be withdrawn at the latest by November 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This doc
34、ument has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium,
35、 Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Sw
36、itzerland, Turkey and the United Kingdom. BS EN 15316-5:2017EN 15316-5:2017 (E) 6 Introduction This European Standard is part of a series of standards aiming at international harmonization of the methodology for the assessment of the energy performance of buildings, called “set of EPB standards”. Al
37、l EPB standards follow specific rules to ensure overall consistency, unambiguity and transparency. All EPB standards provide a certain flexibility with regard to the methods, the required input data and references to other EPB standards, by the introduction of a normative template in Annex A and Ann
38、ex B with informative default choices. EPB standards deal with energy performance calculation and other related aspects (like system sizing) to provide the building services considered in the EPBD. This standard specifies two methods to take into account the energy performance of storage systems for
39、 heating of domestic hot water coupled to generation system(s) producing hot water or using independent energy input to the storage unit. This standard presents two methods applicable to the different technologies of water based storage system and related controls systems: method A applies when the
40、hot water is thermally stratified; method B applies when the hot water contained in the storage unit(s) is thermally homogeneous. The standard covers typically hourly time-step but can be adapted to different time steps accordingly with the scenarios used for energy use and energy delivered. The sub
41、jects covered by CEN/TC 228 are the following: design of heating systems (water based, electrical etc.); installation of heating systems; commissioning of heating systems; instructions for operation, maintenance and use of heating systems; methods for calculation of the design heat loss and heat loa
42、ds; methods for calculation of the energy performance of heating systems. For the correct use of this standard, Annex A is to be used to specify the choices with the required input data for use with method A (hourly calculation time step) or Method B (other calculation time steps). Default values fo
43、r use of the Method A and B monthly and annual methods are provided in Annex B. In case the standard is used in the context of national or regional legal requirements, mandatory choices may be given at national or regional level for such specific applications, in particular for the application withi
44、n the context of EU Directives transposed into national legal requirements. These choices can be made available as National Annex or as separate (e.g. legal) document. It is expected, if the default values and choices in Annex A are not followed due to national regulations, policy or traditions, tha
45、t: either the national standardization body will consider the possibility to add or include a National Annex in agreement with the template of Annex A; or the national or regional authorities will, in the building regulations, reference the standard and prepare data sheets containing the national or
46、 regional choices and values, in agreement with the template of Annex A. Heating systems also include the effect of attached systems such as hot water production systems. BS EN 15316-5:2017EN 15316-5:2017 (E) 7 All these standards are systems standards, i.e. they are based on requirements addressed
47、to the system as a whole and not dealing with requirements to the products within the system. Where possible, reference is made to other European or International Standards, a.o product standards. However, use of products complying with relevant product standards is no guarantee of compliance with t
48、he system requirements. The requirements are mainly expressed as functional requirements, i.e. requirements dealing with the function of the system and not specifying shape, material, dimensions or the like. The guidelines describe ways to meet the requirements, but other ways to fulfil the function
49、al requirements might be used if fulfilment can be proved. Heating systems differ among the member countries due to climate, traditions and national regulations. In some cases, requirements are given as classes so national or individual needs may be accommodated. In cases where the standards contradict with national regulations, the latter should be followed. Table 1 shows the relative position of this standard within the EPB standards. BS EN 15316-5:2017EN 15316-5:2017 (E) 8 1 Scope This European Standard covers en