BS EN 16583-2015 Heat exchangers Hydronic room fan coils units Determination of the sound power level《热交换器 空调房间风机盘管 声功率级的测定》.pdf

上传人:visitstep340 文档编号:573941 上传时间:2018-12-13 格式:PDF 页数:26 大小:1.37MB
下载 相关 举报
BS EN 16583-2015 Heat exchangers Hydronic room fan coils units Determination of the sound power level《热交换器 空调房间风机盘管 声功率级的测定》.pdf_第1页
第1页 / 共26页
BS EN 16583-2015 Heat exchangers Hydronic room fan coils units Determination of the sound power level《热交换器 空调房间风机盘管 声功率级的测定》.pdf_第2页
第2页 / 共26页
BS EN 16583-2015 Heat exchangers Hydronic room fan coils units Determination of the sound power level《热交换器 空调房间风机盘管 声功率级的测定》.pdf_第3页
第3页 / 共26页
BS EN 16583-2015 Heat exchangers Hydronic room fan coils units Determination of the sound power level《热交换器 空调房间风机盘管 声功率级的测定》.pdf_第4页
第4页 / 共26页
BS EN 16583-2015 Heat exchangers Hydronic room fan coils units Determination of the sound power level《热交换器 空调房间风机盘管 声功率级的测定》.pdf_第5页
第5页 / 共26页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 16583:2015Heat exchangers Hydronicroom fan coils units Determination of the soundpower levelBS EN 16583:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 16583:2015.The UK participation in its preparation was entrusted to Techni

2、calCommittee RHE/17, Testing of air conditioning units.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The Britis

3、h Standards Institution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 82138 7ICS 27.060.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 August 20

4、15.Amendments issued since publicationDate Text affectedBS EN 16583:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16583 August 2015 ICS 27.060.30 English Version Heat exchangers - Hydronic room fan coils units - Determination of the sound power level changeurs thermiques - Ventilo-convect

5、eurs eau - Dtermination du niveau de puissance acoustique Wrmebertrager - Wasser-Luft-Ventilatorkonvektoren - Bestimmung des Schallleistungspegels This European Standard was approved by CEN on 27 June 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the

6、 conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard

7、exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national

8、 standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovaki

9、a, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means r

10、eserved worldwide for CEN national Members. Ref. No. EN 16583:2015 EBS EN 16583:2015EN 16583:2015 (E) 2 Contents Page European foreword .3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Measuring instruments .5 5 Operation of the unit .6 6 Installation 7 6.1 General 7 6.2 Non ducted

11、 units7 6.2.1 General 7 6.2.2 Floor mounted unit 7 6.2.3 Wall mounted unit 8 6.2.4 High wall mounted unit .9 6.2.5 Cassette and under ceiling mounted units 10 6.2.6 Under floor mounted 10 6.3 Ducted units 10 6.3.1 General . 10 6.3.2 Discharge or inlet sides . 11 6.3.3 Sound level radiated by the cas

12、ing . 17 7 Acoustic measurement 18 7.1 Frequency range . 18 7.2 Acoustic standard. 18 7.3 Diffuse field . 18 7.4 Free field 19 7.5 In-duct measurement . 19 8 Uncertainty 19 9 Test report . 20 9.1 General information 20 9.2 Additional information . 20 9.3 Test results 20 10 Data to be recorded 21 11

13、Manufacturers data 21 Bibliography . 22 BS EN 16583:2015EN 16583:2015 (E) 3 European foreword This document (EN 16583:2015) has been prepared by Technical Committee CEN/TC 113 “Heat pumps and air conditioning units”, the secretariat of which is held by AENOR. This European Standard shall be given th

14、e status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2016, and conflicting national standards shall be withdrawn at the latest by February 2016. Attention is drawn to the possibility that some of the elements of this document may be

15、 the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Be

16、lgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Swit

17、zerland, Turkey and the United Kingdom. BS EN 16583:2015EN 16583:2015 (E) 4 1 Scope This European Standard applies to hydronic fan coil units (FCU) as factory-made single assemblies which provide the functions of cooling and/or heating but do not include the source of cooling or heating. The standar

18、d covers both air free delivery and air ducted units with a maximum external static pressure due to duct resistance of 120 Pa max. This European Standard provides methods for the determination of the acoustical performance of fan coil units, defining standard working condition and installation. It i

19、s not the purpose of this standard to specify the tests used for production or field testing. NOTE For the purpose of remaining clauses, the term “unit” is used to mean “fan coil unit” as defined in 3.1 of EN 1397:2015. 2 Normative references The following documents, in whole or in part, are normati

20、vely referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1397:2015, Heat exchangers - Hydronic room fan coil units - T

21、est procedures for establishing the performance EN ISO 3741, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for reverberation test rooms (ISO 3741) EN ISO 3743-1, Acoustics - Determination of sound power levels and so

22、und energy levels of noise sources using sound pressure - Engineering methods for small movable sources in reverberant fields - Part 1: Comparison method for a hard-walled test room (ISO 3743-1) EN ISO 3743-2, Acoustics - Determination of sound power levels of noise sources using sound pressure - En

23、gineering methods for small, movable sources in reverberant fields - Part 2: Methods for special reverberation test rooms (ISO 3743-2) EN ISO 3744, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially f

24、ree field over a reflecting plane (ISO 3744) EN ISO 3745, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for anechoic rooms and hemi-anechoic rooms (ISO 3745) EN ISO 9614-1, Acoustics - Determination of sound power le

25、vels of noise sources using sound intensity - Part 1: Measurement at discrete points (ISO 9614-1) EN ISO 9614-2, Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2: Measurement by scanning (ISO 9614-2) EN ISO 9614-3, Acoustics - Determination of sound pow

26、er levels of noise sources using sound intensity - Part 3: Precision method for measurement by scanning (ISO 9614-3) EN ISO 80000-8:2007, Quantities and units - Part 8: Acoustics (ISO 80000-8:2007, corrected 2007-08-15) BS EN 16583:2015EN 16583:2015 (E) 5 3 Terms and definitions For the purposes of

27、this document, the following terms and definitions apply. 3.1 hydronic fan-coil unit factory-made single assembly which provides one or more of the functions of forced circulation of air, heating, cooling, dehumidification and filtering of air, but which does not include the source of heating or coo

28、ling Note 1 to entry: This device includes at least a liquid-to-air heat exchanger and a fan, and may be designed for free or ducted intake air and/or for free or ducted delivery of supply air. 3.2 total electric power input total electric power absorbed by the unit, including fan(s) and auxiliary d

29、evices but excluding any electrical resistance heater 3.3 standard fan speed fan speed setting declared by the manufacturer and used for setting the air flow rate conditions of ducted units Note 1 to entry: The fan speed setting can be declared by the manufacturer as a certain wiring, a switch posit

30、ion or a steering voltage. 3.4 external static pressure positive pressure difference measured between the air outlet and inlet sections of the unit 3.5 acoustics for acoustic quantities, the definitions of EN ISO 80000-8:2007 apply 4 Measuring instruments The acoustic instruments shall fulfil the re

31、quirements of the acoustic standard used for the test. Other measurements can be necessary for the tests: Electrical: voltage (V), current (A), total electric power input (W); Pressure (Pa); Rotation speed (min-1). Measurements for the ambient conditions: Relative humidity (%); Air Temperature (C);

32、Atmospheric pressure (kPa). Table 1 gives the uncertainties allowed for these measurement values. BS EN 16583:2015EN 16583:2015 (E) 6 Table 1 Uncertainties of measurement for indicated values Measured quantity Unit Uncertainty of measurement Air static pressure difference Pa 3 Pa (P 100 Pa) 3% (P 10

33、0 Pa) Electrical quantities Voltage V 0,5 % Current A 0,5 % Power W 1 % or minimum 1 W Rotation speed min-1 1 % Relative humidity HR 5 % Atmospheric pressure kPa 1 % Temperature C 0,5 K 5 Operation of the unit The testing conditions are given in EN 1397:2015 except the following: The acoustic test s

34、hall be performed without connection to water supply, without water staying in the water circuit, with dry coil surface and an inlet air temperatures between 15 C and 25 C. The control of the relative humidity is not required. If the unit includes flaps, they shall be adjusted in a fixed position ac

35、cording to the manufacturer instructions. If this information is not available, their position shall correspond to the maximum mechanical open position. NOTE 1 This maximum mechanical open position might differ from the minimum airflow resistance. For testing, the unit shall include an air filter bu

36、t no any other accessory for air inlet or diffusion or others. Dampers for fresh air intake shall be closed. NOTE 2 No modification such as sealing is made on the unit before testing. For ducted units, an external static pressure difference of 50 Pa ( 1 Pa) shall be applied to the unit for the stand

37、ard fan speed declared by the manufacturer. If other speeds are tested, the same network curve resistance shall be used. See Figure 1. If the resistance is obtained by using an auxiliary fan, preliminary tests shall be done to determine the external static difference for each additional speed. BS EN

38、 16583:2015EN 16583:2015 (E) 7 Key 1 ductwork load curve 2 reference standard speed 3 other speeds X external static pressure difference Y flow rate Figure 1 Setup external static pressure difference of ducted units for other speeds 6 Installation 6.1 General The typical types of units are presented

39、 in the annex of EN 1397:2015. Tests shall be made in suitable acoustic test chambers. 6.2 Non ducted units 6.2.1 General The target is the sound power level radiated by the whole unit, without distinction of inlet or discharge sides nor casing radiation. 6.2.2 Floor mounted unit The unit shall be i

40、nstalled on the hard floor at a minimum of 1 500 mm away from any wall out of any symmetry axis. The feet provided by the manufacturer shall be used. For aerodynamic purpose, the space between the feet shall be closed in the rear part to simulate the wall, with a rigid and reflective plate, with the

41、 same width of the unit and not exceeding its height. See Figure 2. BS EN 16583:2015EN 16583:2015 (E) 8 This plate shall be in chipboard or equivalent, density 600 kg/m to 700 kg/m, and thickness 19 mm to 22 mm. Key 1 fan coil unit 2 feet 3 plate to close the space between the feet on the rear side

42、4 front side of the fan coil unit 5 rear side of the fan coil unit Figure 2 Floor mounted unit with a closing plate between the feet 6.2.3 Wall mounted unit For low-wall mounting units, the distance to the floor given by the manufacturer shall be respected. Without information from the manufacturer,

43、 this distance shall be 150 mm. For aerodynamic purpose, the space between the unit and the floor shall be closed in the rear part to simulate the wall, with a rigid and reflective plane, with the same width of the unit and not exceeding its height. See Figure 3. The characteristics of the frame sha

44、ll be such that any impact on the acoustic measurement by the frame radiation may be avoided. This plate shall be in chipboard or equivalent, density 600 kg/m to 700 kg/m, and thickness 19 mm to 22 mm. BS EN 16583:2015EN 16583:2015 (E) 9 Key 1 fan coil unit 2 supporting frame 3 plate to close the sp

45、ace between the unit and the floor, at the rear side Figure 3 Example of installation low wall unit mounted on a frame, with the back plate 6.2.4 High wall mounted unit The unit shall be installed on a frame at a minimum of 1 500 mm away from any wall, out of any symmetry axis. For high-wall units,

46、the height shall be at a minimum of 1 500 mm from the floor. See Figure 4. The characteristics of the frame shall be such that any impact on the acoustic measurement by the frame radiation may be avoided. Key 1 fan coil unit 2 supporting frame Figure 4 Example of installation of high wall unit mount

47、ed on a frame BS EN 16583:2015EN 16583:2015 (E) 10 6.2.5 Cassette and under ceiling mounted units The unit shall be hung on a frame, using elastic connection (elastic strap or uncoupled rigid stinger) to avoid vibration transmission, linked to the unit according to the manufacturer instructions. No

48、additional plate is allowed on the top of unit to simulate the ceiling. The distance between the bottom of the unit and the floor shall be at a minimum of 1 500 mm, see Figure 5. The distance between the top of the unit and the ceiling of the testing room shall be at least 1 500 mm. Figure 5 Example

49、 of installation of cassette unit mounted on a frame 6.2.6 Under floor mounted The unit shall be installed directly on the floor at a minimum of 1 500 mm away from any wall, out of any symmetry axis (see Figure 6). A soft and thin layer (maximum 5 mm thick and 20 mm width) can be inserted on the perimeter to ensure a good contact between the unit and the floor, avoiding sheet vibrations. Figure 6 Example of unit under floor mounted 6.3 Ducted units 6.3.1 General In the case of free inlet / ducted discharge