1、BS EN 60079-15:2010Explosive atmospheresPart 15: Equipment protection by type of protection “n“(IEC 60079-15:2010)BS EN 60079-15:2010Incorporating corrigendum November 2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 60079-15:2010 BRITISH STANDARDNational fo
2、rewordThis British Standard is the UK implementation of EN 60079-15:2010. It is identical to IEC 60079-15:2010. It supersedes BS EN 60079-15:2005 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EXL/31, Equipment for explosive atmospheres.A list of orga
3、nizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016. Published by BSI Standards Limited 2
4、016ISBN 978 0 580 96227 1ICS 29.260.20Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2010.Amendments/corrigenda issued since publicationDate Text a
5、ffected30 November 2016 Implementation of IEC Interpretation Sheet 1 September 2016 in National Annex NAIEC 60079-15:2010/ISH1:2016 IEC 2016 1 ICS 29.260.20 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ IEC 60079-15 Edition 4.0 2010-01 EXPLOSIVE ATMOSPHERES Part 15: Equipment protection by type of pro
6、tection “n“ INTERPRETATION SHEET 1This interpretation sheet has been prepared by IEC technical committee 31: Equipment for explosive atmospheres. The text of this interpretation sheet is based on the following documents: ISH Report on voting 31/1259/ISH 31/1273/RVD Full information on the voting for
7、 the approval of this interpretation sheet can be found in the report on voting indicated in the above table. _ IEC 60079-15:2010 Edition 4.0, Explosive atmospheres Part 15: Equipment protection by type of protection “n“ Question: Do the requirements given in 8.3 prohibit the use of a terminal box o
8、pened to the interior of a motor rated 1 kV or greater, provided the interior of the machine has an ingress protection of IP54 or greater? IEC 60079-15:2010 Edition 4.0 8.3 Terminal boxes Terminal boxes attached to machines operating at voltages up to 1 kV, may be opened to the interior of the machi
9、ne, only when the IP rating of the machine is IP44 or higher. The external IP protection of the box shall be not less than IP54, as determined in accordance with IEC 60079-0. IEC 60079-15:2010-01/ISH1:2016-09(en-fr)BS EN 60079-15:2010 National Annex NA (informative) 2 IEC 60079-15:2010/ISH1:2016 IEC
10、 2016 Answer: No. As long as the interior of the machine has an ingress protection of IP54 or greater, determined in accordance with IEC 60079-0, there is no limitation to less than 1 kV. If the interior of the machine has an ingress rating of IP44 or lower, the use of a terminal box open to the int
11、erior of a motor rated 1 kV or greater is not permitted. NOTE Many manufacturers opt to declare IP44 for the machine for certification purposes, whilst claiming a rating of IP54 or higher, by assessment, for contractual purposes in order to avoid the difficult testing required for certification of t
12、he IP of larger machines. As such, this additional IP rating need only comply with IEC 60529 or IEC 60034-5 as applicable, and not with any of the testing detailed in IEC 60079-0. BS EN 60079-15:2010 EUROPEAN STANDARD EN 60079-15NORME EUROPENNE EUROPISCHE NORM May 2010 CENELEC European Committee for
13、 Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2010 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref
14、. No. EN 60079-15:2010 E ICS 29.260.20 Supersedes EN 60079-15:2005English version Explosive atmospheres - Part 15: Equipment protection by type of protection “n“ (IEC 60079-15:2010) Atmosphres explosives - Partie 15: Protection du matriel par mode de protection “n“ (CEI 60079-15:2010) Explosionsfhig
15、e Atmosphre - Teil 15: Gerteschutz durch Zndschutzart “n“ (IEC 60079-15:2010) This European Standard was approved by CENELEC on 2010-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a n
16、ational standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A versio
17、n in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cy
18、prus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. 2 IEC 60079-15:2010/ISH1:20
19、16 IEC 2016 Answer:No. As long as the interior of the machine has an ingress protection of IP54 or greater,determined in accordance with IEC 60079-0, there is no limitation to less than 1 kV. If the interior of the machine has an ingress rating of IP44 or lower, the use of a terminal box open to the
20、 interior of a motor rated 1 kV or greater is not permitted.NOTE Many manufacturers opt to declare IP44 for the machine for certification purposes, whilst claiming a rating of IP54 or higher, by assessment, for contractual purposes in order to avoid the difficult testing required forcertification of
21、 the IP of larger machines. As such, this additional IP rating need only comply with IEC 60529 orIEC 60034-5 as applicable, and not with any of the testing detailed in IEC 60079-0. EN 60079-15:2010 - 2 - Foreword The text of document 31/833/FDIS, future edition 4 of IEC 60079-15, prepared by IEC TC
22、31, Equipment for explosive atmospheres, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60079-15 on 2010-05-01. This European Standard supersedes EN 60079-15:2005. The significant technical changes with respect to EN 60079-15:2005 are as follows: addition of equipme
23、nt protection levels; removal of the requirements for energy-limited “nL” and associated energy limited apparatus “nL”; removal of the requirements for encapsulated Devices “nC”; requirements for electrical connections expanded and clarified; requirements for luminaire ballasts expanded and clarifie
24、d; requirements for evaluation and testing of motor rotors clarified; 15 kV limit for equipment protection by type of protection “n“ added; spacing requirement for voltages above 10 kV modified; requirements for restricted breathing enclosures modified; modification to requirements for motor rotors
25、and stators; addition of Annex A (informative); undated references to IEC 60079-0 included.This standard is to be used in conjunction with EN 60079-0. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and CENELEC shall not be he
26、ld responsible for identifying any or all such patent rights. The following dates were fixed: latest date by which the EN has to be implementedat national level by publication of an identicalnational standard or by endorsement (dop) 2011-02-01 latest date by which the national standards conflictingw
27、ith the EN have to be withdrawn (dow) 2013-05-01 This European Standard has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Association and covers essential requirements of EC Directive 94/9/EC. See Annex ZZ. Annexes ZA, ZY and ZZ have been added
28、 by CENELEC. _ BS EN 60079-15:2010- 3 - EN 60079-15:2010 Endorsement notice The text of the International Standard IEC 60079-15:2010 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standa
29、rds indicated: IEC 60034-5 NOTE Harmonized as EN 60034-5. IEC/TS 60034-17 NOTE Harmonized as CLC/TS 60034-17. IEC 60068-2-6 NOTE Harmonized as EN 60068-2-6. IEC 60079-7:2006 NOTE Harmonized as EN 60079-7:2007 (not modified). IEC 60079-17 NOTE Harmonized as EN 60079-17. IEC 60079-18 NOTE Harmonized a
30、s EN 60079-18. IEC 60079-29-2 NOTE Harmonized as EN 60079-29-2. IEC 60297 series NOTE Harmonized in EN 60297 series (not modified). _ BS EN 60079-15:2010EN 60079-15:2010 - 4 - Annex ZA (normative) Normative references to international publications with their corresponding European publications The f
31、ollowing referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modifi
32、ed by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60034 Series Rotating electrical machines EN 60034 Series IEC 60034-1 - Rotating electrical machines - Part 1: Rating and performance EN 60034-1 - IEC/TS 60034-25 - Rotating electrical m
33、achines - Part 25: Guidance for the design and performance of a.c. motors specifically designed for converter supply CLC/TS 60034-25 - IEC 60061 Series Lamp caps and holders together with gauges for the control of interchangeability and safety - - IEC 60061-1 - Lamp caps and holders together with ga
34、uges for the control of interchangeability and safety - Part 1: Lamp caps EN 60061-1 - IEC 60068-2-27 2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock EN 60068-2-27 2009 IEC 60079-0 2007 Explosive atmospheres - Part 0: Equipment - General requirements EN 60079-0 2009 IEC 6
35、0079-1 - Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures “d“ EN 60079-1 - IEC 60079-11 - Explosive atmospheres - Part 11: Equipment protection by intrinsic safety “i“ EN 60079-11 - IEC 60112 - Method for the determination of the proof and the comparative tracking indice
36、s of solid insulating materials EN 60112 - IEC 60155 - Glow-starters for fluorescent lamps EN 60155 - IEC 60228 - Conductors of insulated cables EN 60228 - IEC 60238 - Edison screw lampholders EN 60238 - IEC 60269-3 - Low-voltage fuses - Part 3: Supplementary requirements for fuses for use by unskil
37、led persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F HD 60269-3 - IEC 60400 - Lampholders for tubular fluorescent lamps and starterholders EN 60400 - BS EN 60079-15:2010- 5 - EN 60079-15:2010 Publication Year Title EN/HD Year IEC 60529 -
38、 Degrees of protection provided by enclosures (IP Code) EN 60529 - IEC 60598 Series Luminaires EN 60598 Series IEC 60598-1 (mod) - 2008 - Luminaires - Part 1: General requirements and tests EN 60598-1 + A11 2008 2009 IEC 60598-2 Series Luminaires - Part 2: Particular requirements EN 60598-2Series IE
39、C 60664-1 - Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests EN 60664-1 - IEC 60927 - Auxiliaries for lamps - Starting devices (other than glow starters) - Performance requirements EN 60927 - IEC 60947-7-1 - Low-voltage switchgear and cont
40、rolgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors EN 60947-7-1 - IEC 60947-7-2 - Low-voltage switchgear and controlgear - Part 7-2: Ancillary equipment - Protective conductor terminal blocks for copper conductorsEN 60947-7-2 - IEC 60998-2-4 - Connecting devices for low
41、voltage circuits for household and similar purposes - Part 2-4: Particular requirements for twist-on connecting devices EN 60998-2-4 - IEC 60999-1 - Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements
42、 and particular requirements for clamping units for conductors from 0,2 mm up to 35 mm (included) EN 60999-1 - IEC 60999-2 - Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units f
43、or conductors above 35 mm up to 300 mm (included) EN 60999-2 - IEC 61048 - Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements EN 61048 - IEC 61184 - Bayonet lampholders EN 61184 - IEC 61195 - Double-capped fluorescent
44、 lamps - Safety specifications EN 61195 - IEC 61347-1 (mod) 2007 Lamp controlgear - Part 1: General and safety requirements EN 61347-1 2008 IEC 61347-2-1 - Lamp controlgear - Part 2-1: Particular requirements for starting devices (other than glow starters) EN 61347-2-1 - IEC 61347-2-2 - Lamp control
45、gear - Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps EN 61347-2-2 - IEC 61347-2-3 - Lamp controlgear - Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lampsEN 61347-2-3 - BS EN 60079-15:2010EN 60
46、079-15:2010 - 6 - Publication Year Title EN/HD Year IEC 61347-2-4 - Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting EN 61347-2-4 - IEC 61347-2-7 - Lamp controlgear - Part 2-7: Particular requirements for d.c. supplied electronic ballast
47、s for emergency lighting EN 61347-2-7 - IEC 61347-2-8 - Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps EN 61347-2-8 - IEC 61347-2-9 - Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) EN 61347-
48、2-9 - BS EN 60079-15:2010- 7 - EN 60079-15:2010 Annex ZY (informative) Significant changes between this European Standard and EN 60079-15:2005 This European Standard supersedes EN 60079-15:2005. The significant changes with respect to EN 60079-15:2005 are as listed below. TypeMinor and editorial cha
49、nges Extension Substantial change regarding ESRs aAddition of Equipment Protection Levels X Removal of the requirements for Energy-limited “nL“ and associated energy limited apparatus “nL“ X Removal of the requirements for Encapsulated Devices “nC“ X Requirements for electrical connections expanded and clarified X Requirements for luminaire ballasts expanded and clarified X Requirements for evaluation and testing of motors rotors clarified X 15 kV limit for Equipment protection b