1、BRITISH STANDARD BS EN 60966-3-2:2003 Radio frequency and coaxial cable assemblies Part 3-2: Detail specification for semi-flexible coaxial cable assemblies for GSM use (0,8 GHz 1 GHz) The European Standard EN 60966-3-2:2003 has the status of a British Standard ICS 33.120.10 BS EN 60966-3-2:2003 Thi
2、s British Standard was published under the authority of the Standards Policy and Strategy Committee on 18 November 2003 BSI 18 November 2003 ISBN 0 580 42915 6 National foreword This British Standard is the official English language version of EN 60966-3-2:2003. It is identical with IEC 60966-3-2:20
3、03. It supersedes BS EN 60966-3-2:1999 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee EPL/46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, to Subcommittee EPL/46/1, Coaxial cables, which has the r
4、esponsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entit
5、led “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance
6、 with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related inte
7、rnational and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 8, an inside back cover and a back cover. The BSI copyright notice displayed in this document indicates when the document wa
8、s last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEAN STANDARD EN 60966-3-2 NORME EUROPENNE EUROPISCHE NORM October 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnisch
9、e Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 60966-3-2:2003 E ICS 33.120.10 Supersedes EN 60966-3-2:1999English version Radio frequency and coaxial cable
10、 assemblies Part 3-2: Detail specification for semi-flexible coaxial cable assemblies for GSM use (0,8 GHz - 1 GHz) (IEC 60966-3-2:2003) Ensembles de cordons coaxiaux et de cordons pour frquences radiolectriques Partie 3-2: Spcification particulire pour cordons coaxiaux semi-flexibles pour applicati
11、ons GSM (0,8 GHz - 1 GHz) (CEI 60966-3-2:2003) Konfektionierte Koaxial- und Hochfrequenzkabel Teil 3-2: Bauartspezifikation fr halbflexible konfektionierte Koaxialkabel fr GSM-Anwendungen (0,8 GHz - 1 GHz) (IEC 60966-3-2:2003) This European Standard was approved by CENELEC on 2003-10-01. CENELEC mem
12、bers are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on applicat
13、ion to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat
14、has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Lithuania, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, S
15、weden, Switzerland and United Kingdom. EN 66906-3-2:0230 - - 2 Foreword The text of document 46A/550/FDIS, future edition 2 of IEC 60966-3-2, prepared by SC 46A, Coaxial cables, of IEC TC 46, Cables, wires, waveguides, r.f. connectors, r.f. and microwave passive components and accessories, was submi
16、tted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60966-3-2 on 2003-10-01. This European Standard supersedes EN 60966-3-2:1999. The major change with respect to EN 60966-3-2:2003 is the reference to the 1999 edition of the generic specification EN 60966-1. The following dates w
17、ere fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2004-07-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2006-10-01 This detail specification is to
18、 be read with EN 60966-1:1999, Radio frequency and coaxial cable assemblies Part 1: Generic specification - General requirements and test methods, with EN 60966-3:2003, Radio frequency and coaxial cable assemblies Part 3: Sectional specification for semi-flexible coaxial cable assemblies and with EN
19、 60966-3-1:2003, Radio frequency and coaxial cable assemblies Part 3-1: Blank detail specification for semi-flexible coaxial cable assemblies. Annexes designated “normative“ are part of the body of the standard. In this standard, annex ZA is normative Annex ZA has been added by CENELEC. _ Endorsemen
20、t notice The text of the International Standard IEC 60966-3-2:2003 was approved by CENELEC as a European Standard without any modification. In the official version, add the following note at the end: NOTE IEC 60169-4:1975 is harmonized as HD 134.4 S2:1977. _ Page2 EN6096632:2003 INTRODUCTION This pa
21、rt of IEC 60966 is a detail specification that relates to the subfamily of coaxial cables and connector assemblies operating in the frequency range of GSM (0,8 GHz to 1 GHz). They are designed with a cable having a diameter of 13 mm and connectors from IEC 60169-4 (type 7-16). This detail specificat
22、ion gives subfamily requirements and severities which should be applied. Under Qualification Approval, the qualification will be conducted in accordance with 12.2 of IEC 60966-3 taking into account the specified variants. Only the tests whose results might depend on the variants will be repeated Und
23、er Capability Approval, the qualification will be conducted on the relating CQCs as defined in 12.3 of IEC 60966-3 and described in the CM. Unless otherwise specified in the CM, only lot- by-lot tests from groups Ba and Eb will be conducted on delivered products; all other tests will be performed on
24、 CQCs as defined in 12.3 of IEC 60966-3 and described in the CM. Reference document: IEC 60169-4:1975, Radio-frequency connectors Part 4: RF coaxial connectors with inner diameter of outer conductor 16 mm (0,63 in) with screw lock Characteristic impedance 50 ohms (type 7-16) Page3 EN6096632:2003 1 P
25、repared by IEC SC 46A 2 Document n 60966-3-2 Indice/Issue: Second issue Date: 3 Available from: IEC 3 rue de Varemb Genve Suisse 4: Generic specification CEI/IEC 60966-1 Sectional specification CEI/IEC 60966-3 Blank detail specification: CEI/IEC 60966-3-1 5 Additional references: IEC 60169-4 Detail
26、specification for semi-flexible coaxial assemblies for GSM use (0,8 GHz to 1 GHz) L IEC 2054/037 Characteristic impedance: 50 8 Frequency range: 0,8 GHz to 1 GHz 9 Weight: 200 g/m + 180 g/m 10 Minimum inside radius: for static bending 30 mm for dynamic bending 180 mm 11 Climatic category: 40/70/21 1
27、2 Applicable test group: Ba, Eb, Eh, Ee, Et, Mn, Vv, Vc, Vt, Vf 13 Connector type Cable type a IEC 60169-4(7-16) Straight plug 13 mm b IEC 60169-4(7-16) Straight plug 13 mm c IEC 60169-4(BNC) Right-angle plug 13 mm Marking method: Marking sleeves Marking text: CEI/Manufacturer identification and IEC
28、 reference: 60966-3-2 14 Variants 1 a-a 2 c-c 3 a-b 4 b-c 15 Page 1 of 5 pages 6 Page4 EN6096632:2003 16 Inspection values, ratings or characteristics 17 Subclause 18 Value 19 Remarks Electrical Reflection properties 8.1 26 dB 0,8 GHz to 1 GHz from both ends Insertion loss 8.3 110 dB Up to 1 GHz Vol
29、tage proof 8.10 2,5 kV Peak value 50 Hz Insulation resistance 8.11 10 5 M Test voltage 500 V, 1 min Inner and outer conductor continuity 8.12 OK/no Low-voltage d.c. Power rating 8.14 Under consideration Intermodulation level 8.5 Under consideration Mechanical Tensile 9.1 Interface OK/no 280 N Durati
30、on 3 mn Return loss 26 dB Cable crushing 9.4 Interface OK/no 70 N Return loss 26 dB Torque 9.5 Interface OK/no 4 Nm Return loss 26 dB Multiple bending 9.6 Interface OK/no 20 cycles, r = 100 mm Return loss 26 dB Page5 EN6096632:2003 16 Inspection values, ratings or characteristics 17 Subclause 18 Val
31、ue 19 Remarks Environmental Vibration 10.2 OK/no 100 m/s 10-2 000 Hz 10 g Bumps 10.2 OK/no 390 m/s 40 000 bumps 40 g Shock 10.2 OK/no 300 m/s 1/2 sine 18 ms 30 g Climatic sequence 10.3 OK/no 3 cycles 40/70/1 000 Damp heat, steady state 10.4 OK/no 3 cycles 1 000 h test 8.3 Rapid change of temperature
32、 10.5 OK/no 40 C +70 C Test 8.3, 8.10, 8.11 Solvents and contaminating fluids 10.6 Not applicable Water immersion 10.7 OK/no With mated connectors Salt mist and sulphur dioxide 10.8 OK/no Dust tests 10.9 OK/no Flammability 10.10 OK/no Page6 EN6096632:2003Grouping of tests for specification purposes
33、Recommended grouping of tests Recommended severity 20 Group Tests 21 Subclause 22 Periodicity 23 NC IL 24 NQA AQL 25 n 26 c 27 Specimen Ba Visual inspection Dimensional inspection 7.2 7.3 Lot by lot Lot by lot II S4 I 0,4 % Eh Reflection properties Insertion loss 8.1 8.3 Lot by lot Lot by lot 100 %
34、100 %Eb Voltage proof Insulation resistance Inner and outer conductor continuity 8.10 8.11 8.12 Lot by lot Lot by lot Lot by lot S4 S4 100 % 0,4 % 0,4 % Ee Screening effectiveness 8.9 18 months 10 0 Two of each variant Mn Tensile Cable crushing Torque Multiple bending 9.1 9.4 9.5 9.6 18 months 3 yea
35、rs 6 months 3 years 10 2 10 2 1 0 1 0 Two of each variant On original length of cable Two of each variant On original length of cable Page7 EN6096632:2003 Recommended grouping of tests Recommended severity 20 Group Test 21 Subclause 22 Periodicity 23 NC IL 24 NQA AQL 25 n 26 c 27 Specimen Et Power r
36、ating 8.14 3 years Vv Vibration, bumps, shock 10.2 18 months 10 1 Two of each variant Vc Climatic sequence 10.3 3 years 5 0 One of each variant Vt Damp heat, steady state Rapid change of temperature Salt mist and sulphur dioxide 10.4 10.5 10.8 18 months 3 years 3 years 10 5 5 0 0 0 Two of each varia
37、nt One of each variant One of each variant Vf Water immersion Dust tests Flammability 10.7 10.9 10.10 18 months 18 months 18 months 5 5 5 1 1 One of each variant _ Page8 EN6096632:2003blankBS EN 60966-3-2:2003 BSI 389 Chiswick High Road London W4 4AL BSI British Standards Institution BSI is the inde
38、pendent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter. Revisions British Standards are updated by amendment or revision. Users of British Standards should make sure that th
39、ey possess the latest amendments or editions. It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the
40、identity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400. BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards. Buying standards Orders for all BSI, inte
41、rnational and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-. In response to orders for international standards, it is BSI policy to su
42、pply the BSI implementation of those that have been published as British Standards, unless otherwise requested. Information on standards BSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various
43、 BSI electronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-. Subscribing members of BSI are kept up to date with standards developments and receive sub
44、stantial discounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-. Information regarding online access to British Standards via British Standards Online can be fo
45、und at http:/www.bsi- Further information about BSI is available on the BSI website at http:/www.bsi-. Copyright Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyrig
46、ht, Designs and Patents Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI. This does not preclude the free use, in the course of implementing the st
47、andard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained. Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553. Email: copyrightbsi-.