1、BRITISH STANDARD BS EN 61076- 4-100:2002 IEC 61076- 4-100:2001 Connectors for electronic equipment Part 4-100: Printed board connectors with assessed quality Detail specification for two-part connector modules having a grid of 2,5 mm for printed boards and backplanes The European Standard EN 61076-4
2、-100:2001 has the status of a British Standard ICS 31.220.10 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBS EN 61076-4-100:2002 This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under
3、the authority of the Standards Policy and Strategy Committee on 18 January 2002 BSI 18 January 2002 ISBN 0 580 38852 2 National foreword This British Standard is the official English language version of EN 61076-4-100:2001. It is identical with IEC 61076-4-100:2001. It supersedes BS EN 61076-4-100:1
4、998 which is withdrawn. The UK participation in its preparation was entrusted by Technical Committee EPL/48, Electromechanical components for electronic equipment, to Subcommittee EPL/48/2, Connectors for electronic equipment, which has the responsibility to: A list of organizations represented on t
5、his subcommittee can be obtained on request to its secretary. From 1 January 1997, all IEC publications have the number 60000 added to the old number. For instance, IEC 27-1 has been renumbered as IEC 60027-1. For a period of time during the change over from one numbering system to the other, public
6、ations may contain identifiers from both systems. Cross-references The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by us
7、ing the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunit
8、y from legal obligations. aid enquirers to understand the text; present to the responsible European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summa
9、ry of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 70, an inside back cover and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date Comments
10、EUROPEAN STANDARD EN 61076-4-100 NORME EUROPENNE EUROPISCHE NORM December 2001 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2
11、001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 61076-4-100:2001 E ICS 31.220.10 Supersedes EN 61076-4-100:1998 English version Connectors for electronic equipment Part 4-100: Printed board connectors with assessed quality - D
12、etail specification for two-part connector modules having a grid of 2,5 mm for printed boards and backplanes (IEC 61076-4-100:2001) Connecteurs pour quipements lectroniques Partie 4-100: Connecteurs pour cartes imprimes - Spcification particulire pour les modules de connecteurs en deux parties pour
13、cartes imprimes et fonds de panier, au pas de 2,5 mm (CEI 61076-4-100:2001) Steckverbinder fr elektronische Einrichtungen Teil 4-100: Steckverbinder fr gedruckte Schaltungen mit bewerteter Qualitt - Bauartspezifikation fr indirekte Steckverbinder fr gedruckte Schaltungen und Rckplatten, modulare Bau
14、weise, Raster 2,5 mm (IEC 61076-4-100:2001) This European Standard was approved by CENELEC on 2001-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alter
15、ation. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tr
16、anslation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Gree
17、ce, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.EN 61076-4-100:2001 - 2 - Foreword The text of document 48B/1086/FDIS, future edition 2 of IEC 61076-4-100, prepared by SC 48B, Connectors, of IEC TC 48, Electromechanical com
18、ponents and mechanical structures for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 61076-4-100 on 2001-12-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical n
19、ational standard or by endorsement (dop) 2002-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2004-12-01 Annexes designated “normative“ are part of the body of the standard. In this standard, annexes A and ZA are normative. Annex ZA has been added
20、 by CENELEC. _ Endorsement notice The text of the International Standard IEC 61076-4-100:3001 was approved by CENELEC as a European Standard without any modification. _ Page2 1002:001467016NE 2002yraunaJ61ISB Page4BSI18January2002 4egaP 1002:001467016NEPage2 EN610764100:2001 67016-4-01 0 IEC:0210 3
21、CONTENTS 1 General data 8 1.1 Recommended method of mounting 8 1.2 Ratings and characteristics. 8 1.3 Normative references . 9 1.4 Marking 9 1.5 IEC type designation10 1.6 Ordering information10 2 Technical information11 2.1 Definitions .11 2.1.1 Backplane male contact arrangement 11 2.2 Survey of s
22、tyles and variants.12 2.3 Information on application13 2.3.1 Complete connectors (pairs) 13 2.3.2 Fixed board connectors14 2.3.3 Free board connectors.14 2.3.4 Accessories .14 2.3.5 Shielding/grounding .14 2.3.6 Basic type of termination14 2.4 Contact arrangements .15 2.4.1 Fixed board connectors15
23、2.4.2 Free board connectors.16 3 Dimensional information .17 3.1 General .17 3.2 Isometric view and common features .18 3.2.1 Common features 19 3.2.2 Reference system19 3.2.3 Height dimensions .20 3.2.4 Width dimensions.21 3.2.5 Depth dimensions 22 3.3 Engagement (mating) information 23 3.3.1 Elect
24、rical engagement length.23 3.3.2 Inclination25 3.3.3 Planarity 25 3.4 Fixed board connectors .25 3.4.1 Dimensions25 3.4.2 Terminations32 3.5 Free board connectors.33 3.5.1 Dimensions33 3.5.2 Terminations38 3.6 Accessories.38 3.7 Mounting information for fixed board connectors39 3.7.1 Hole pattern on
25、 panels.39 3.8 Mounting information for free board connectors .40 3.8.1 Hole pattern on printed boards.40 3.8.2 Requirements for press-in tools .41 Page3 1002:001467016NE 2002yraunaJ61ISB Page5BSI18January2002 5egaP 1002:001467016NEPage3 EN610764100:2001 67016-4-01 0 IEC:0210 4 3.9 Gauges42 3.9.1 Si
26、zing gauges and retention force gauges42 4 Characteristics43 4.1 Climatic category.43 4.2 Electrical .43 4.2.1 Creepage and clearance distances 43 4.2.2 Voltage proof (applicable for PL1, 2, 3)43 4.2.3 Current-carrying capacity (applicable for PL1, 2, 3)44 4.2.4 Contact resistance.45 4.2.5 Insulatio
27、n resistance45 4.3 Mechanical 46 4.3.1 Mechanical operation.46 4.3.2 Insertion and withdrawal forces46 4.3.3 Contact retention in insert46 4.3.4 Static load, axial 46 4.3.5 Vibration (sinusoidal) .46 5 Test schedule .47 5.1 General .47 5.1.1 Arrangement for contact resistance measurement49 5.1.2 Arr
28、angement for dynamic stress tests 49 5.1.3 Arrangement for testing static load, axial .49 5.1.4 Wiring arrangement for insulation resistance, voltage proof and polarization voltage during damp heat test.50 5.1.5 Arrangement for flammability test.50 5.1.6 Arrangement for measurement of the press-in c
29、onnections (female connector) .51 5.1.7 Planarity of mounted connectors52 5.1.8 Test board for fixed and free board connectors 53 5.2 Test schedule tables54 5.2.1 Preliminary group P .54 5.2.2 Group AP Dynamic/climatic.55 5.2.3 Group BP Mechanical endurance58 5.2.4 Group CP Moisture .59 5.2.5 Group
30、DP Electrical load.60 5.2.6 Group EP Mechanical resistivity61 5.2.7 Group FP Chemical fluids .62 5.2.8 Group GP Connections .62 6 Quality assessment procedures 63 6.1 Qualification approval testing.63 6.1.1 Method 1 .63 6.1.2 Method 2 .64 6.2 Quality conformance inspection .64 6.2.1 Lot-by-lot tests
31、.64 6.2.2 Periodic tests.65 6.3 Delayed delivery, re-inspection66 Annex A (normative) Mechanical structures67 Annex ZA (normative) Normative references to internataional publications withthere corresponding European publications 69 1002:001467016NE 2002yraunaJ61ISB Page6 BSI18January2002 6egaP 1002:
32、001467016NEPage4 EN610764100:2001 67016-4-01 0 IEC:0210 5 Figure 1 Backplane male contact arrangement.11 Figure 2 Free and fixed board connectors for modular arrangement 13 Figure 3 Contact arrangements 15 Figure 4 Contact arrangements 16 Figure 5 Isometric view 18 Figure 6 Height dimensions20 Figur
33、e 7 Width dimensions .21 Figure 8 Depth dimensions.22 Figure 9 Mating conditions .23 Figure 10 First contact point.24 Figure 11 Perpendicular to engagement (mating) direction.24 Figure 12 Inclination.25 Figure 13 Style A .26 Figure 14 Details W and X and views U and V27 Figure 15 Style B .28 Figure
34、16 Style D .29 Figure 17 Style G .30 Figure 18 Style H .31 Figure 19 Terminations 32 Figure 20 Style A .33 Figure 21 View X and details U, V, W, Y and Z.34 Figure 22 Style B .35 Figure 23 Style D .36 Figure 24 Style G .37 Figure 25 Style H .38 Figure 26 Terminations 38 Figure 27 Hole pattern on pane
35、ls .39 Figure 28 Hole pattern on printed boards .40 Figure 29 Hole pattern on printed boards .41 Figure 30 Gauge dimensions42 Figure 31 Current-carrying capacity44 Figure 32 Measuring points 45 Figure 33 Dynamic stress tests arrangements 49 Figure 34 Wiring of specimen.50 Figure 35 Arrangement for f
36、lammability test .50 Figure 36 Press-in connections (female connector) measurement arrangements51 Figure 37 Planarity of mounted connectors.52 Figure 38 Test board for fixed and free board connectors.53 Figure A.1 Plug-in unit dimension.68 Page5 1002:001467016NE 2002yraunaJ61ISB Page7BSI18January200
37、2 7egaP 1002:001467016NEPage5 EN610764100:2001 67016-4-01 0 IEC:0210 6 Table 1 Rated voltage .8 Table 2 Contact arrangement and number of contacts12 Table 3 Styles of termination12 Table 4 Isometric view and common features .19 Table 5 Height dimensions .20 Table 6 Width dimensions 21 Table 7 Depth
38、dimensions22 Table 8 Ranges of safe contact performance23 Table 9 Dimensions of terminations32 Table 10 Hole pattern on panels.39 Table 11 Hole pattern on printed boards.41 Table 12 Gauges42 Table 13 Climatic category.43 Table 14 Minimum creepage and clearance distances43 Table 15 Voltage proof.43 T
39、able 16 Current-carrying capacity at 70 C.44 Table 17 Number of mechanical operations46 Table 18 Insertion and withdrawal forces46 Table 19 Vibration severity.46 Table 20 Number of specimens 48 Table 21 Dynamic stress tests49 Table 22 Test board for fixed and free board connectors53 Table 23 Perform
40、ance levels63 Table 24 Lot-by-lot tests.64 Table 25 Periodic tests.65 Table 26 Delayed delivery, re-inspection66 Table A.1 Dimensions required in accordance with IEC 60917-2-2 .67 Page6 1002:001467016NE 2002yraunaJ61ISB Page8BSI18January2002 8egaP 1002:001467016NEPage6 EN610764100:2001 67016-4-01 0
41、IEC:0210 7 CONNECTORS FOR ELECTRONIC EQUIPMENT Part 4-100: Printed board connectors with assessed quality Detail specification for two-part connector modules having a grid of 2,5 mm for printed boards and backplanes IEC 61076-4-100 QC 480301XX0001 IEC SC 48B: LF connectors Specification available fr
42、om: IEC Central Office or from the addresses shown on the inside cover. ELECTRONIC COMPONENTS OF ASSESSED QUALITY IN ACCORDANCE WITH: GENERIC SPECIFICATION IEC 61076-1 First edition:1995 Page 15 of 138 pages Modular two-part connector for printed boards and backplanes, grid of 2,5 mm in accordance w
43、ith IEC 60917 Connector with height multiple modules n 25 mm, (with n = 1, 2, 4, 9,10) five rows See clause 3 for dimensions Performance levels (PL): 1, 2, 3 Assessment levels: B and G * ) Combinations of performance and assessment levels: 1G, 2B, 2G, 3B *) See 6.2 and 6.3. IEC 1839/01 Page7 1002:00
44、1467016NE 2002yraunaJ61ISB Page9BSI18January2002 9egaP 1002:001467016NEPage7 EN610764100:2001 67016-4-01 0 IEC:0210 8 1 General data 1.1 Recommended method of mounting The free board connectors are provided either with solder or with press-in contacts. The mounting of the free board connector is ach
45、ieved by press-in pivots. The terminations of the free board connectors shall fit into holes in the printed board according to IEC 60326-3, located on a grid of 2,5 mm. The fixed board connectors are provided either with: press-in contacts; press-in and wrap contacts; press-in and wrap and mating ar
46、ea contacts. The connector is fixed on the press-in contacts. Fixing holes on the backplane are not necessary. The distance of termination centre lines is 2,5 mm or a multiple of it. The terminations of the fixed board connectors are suited for backplanes having a grid dimension of 2,5 mm. NOTE Info
47、rmation about manufacturers who have components qualified to this detail specification is given in the Qualified Products List. 1.2 Ratings and characteristics Rated voltage: Contact/contact for fully loaded connector (arrangement 1) Table 1 Rated voltage Material group Pollution degree Rated voltag
48、e V I, II, IIIa/b 1 250 II, IIIa/b 2 32 NOTE Reference is made to table 14 of this specification, and table 4 of IEC 60664-1 listing the relation between creepage distances, pollution degree and material groups versus voltages r.m.s. Current rating: 1 A at 70 C for fully loaded connector (arrangement 1) Insulation resistance: 10 6M min. for PL1 and PL2 10 5M min. for PL3 Climatic category: PL1: 55/125/56 PL2: 55/125/21 PL3: 25/100/00 Printed board thickness: 1,6 mm to 3,2 mm for free board connector 1,6 mm mi