BS EN 61169-45-2014 Radio-frequency connectors Sectional specification for series SQMA series quick lock RF coaxial connectors《射频连接器 SQMA系列快锁射频 (RF) 连接器的分规格》.pdf

上传人:medalangle361 文档编号:577024 上传时间:2018-12-13 格式:PDF 页数:30 大小:1.38MB
下载 相关 举报
BS EN 61169-45-2014 Radio-frequency connectors Sectional specification for series SQMA series quick lock RF coaxial connectors《射频连接器 SQMA系列快锁射频 (RF) 连接器的分规格》.pdf_第1页
第1页 / 共30页
BS EN 61169-45-2014 Radio-frequency connectors Sectional specification for series SQMA series quick lock RF coaxial connectors《射频连接器 SQMA系列快锁射频 (RF) 连接器的分规格》.pdf_第2页
第2页 / 共30页
BS EN 61169-45-2014 Radio-frequency connectors Sectional specification for series SQMA series quick lock RF coaxial connectors《射频连接器 SQMA系列快锁射频 (RF) 连接器的分规格》.pdf_第3页
第3页 / 共30页
BS EN 61169-45-2014 Radio-frequency connectors Sectional specification for series SQMA series quick lock RF coaxial connectors《射频连接器 SQMA系列快锁射频 (RF) 连接器的分规格》.pdf_第4页
第4页 / 共30页
BS EN 61169-45-2014 Radio-frequency connectors Sectional specification for series SQMA series quick lock RF coaxial connectors《射频连接器 SQMA系列快锁射频 (RF) 连接器的分规格》.pdf_第5页
第5页 / 共30页
亲,该文档总共30页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、BSI Standards PublicationRadio-frequency connectorsPart 45: Sectional specification for seriesSQMA series quick lock RF coaxial connectorsBS EN 61169-45:2014National forewordThis British Standard is the UK implementation of EN 61169-45:2014. It isidentical to IEC 61169-45:2014.The UK participation i

2、n its preparation was entrusted to TechnicalCommittee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport t

3、o include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2014.Published by BSI Standards Limited 2014ISBN 978 0 580 84383 9ICS 33.120.30Compliance with a British Standard cannot confer immunity fromlegal obligations.Thi

4、s British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2014.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 61169-45:2014EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 61169-45 August 2014 ICS 33.120

5、.30 English Version Radio-frequency connectors -Part 45: Sectional specification for series SQMA series quick lock RF coaxial connectors (IEC 61169-45:2014) Connecteurs pour frquences radiolectriques - Partie 45:Spcification intermdiaire relative aux connecteurscoaxiaux RF verrouillage rapide, srie

6、SQMA (CEI 61169-45:2014) Hochfrequenz-Steckverbinder - Teil 45:Rahmenspezifikation fr koaxiale HF Steckverbinder derSQMA-Serie mit Schnellverriegelung (IEC 61169-45:2014) This European Standard was approved by CENELEC on 2014-06-27. CENELEC members are bound to comply with the CEN/CENELEC Internal R

7、egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELE

8、C member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official ve

9、rsions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, t

10、he Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normalisation ElectrotechniqueEuropisches Komitee fr Elektrotechnische Normung CEN-CENELEC Manage

11、ment Centre: Avenue Marnix 17, B-1000 Brussels 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. EN 61169-45:2014 E EN 61169-45:2014 - 2 - Foreword The text of document 46F/238/CDV, future edition 1 of IEC 61169-45, prepared by SC 4

12、6F, “R.F. and microwave passive components“, of IEC TC 46, “Cables, wires, waveguides, R.F. connectors, R.F. and microwave passive components and accessories“ was submitted to the IEC-CENELEC parallel vote and approved by CENELEC as EN 61169-45:2014. The following dates are fixed: latest date by whi

13、ch the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2015-03-27 latest date by which the national standards conflicting with the document have to be withdrawn (dow) 2017-06-27 Attention is drawn to the possibility that some

14、of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. Endorsement notice The text of the International Standard IEC 61169-45:2014 was approved by CENELEC as a European Standard without any

15、 modification. BS EN 61169-45:2014- 3 - EN 61169-45:2014 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its appl

16、ication. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies.

17、 NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here: www.cenelec.eu. Publication Year Title EN/HD Year IEC 61169-1 2013 Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods EN 61169-

18、1 2013 BS EN 61169-45:2014 2 IEC 61169-45:2014 IEC 2014 CONTENTS 1 Scope 6 2 Normative references 6 3 Mating face and gauge information 6 3.1 Dimensions General connectors Grade 2 6 Connector with pin-centre contact (see Figure 1) . 6 3.1.1Connector with socket-centre contact (see Figure 2) . 8 3.1.

19、23.2 Gauges . 9 Gauge pins for socket-centre contact (see Figure 3) 9 3.2.1Test procedure 9 3.2.23.3 Dimensions Standard test connectors Grade 0 10 Connector with pin-centre contact (see Figure 4) . 10 3.3.1Connector with socket-centre contact (see Figure 5) . 11 3.3.24 Quality assessment procedure

20、. 12 4.1 General . 12 4.2 Ratings and characteristics . 12 4.3 Test schedule and inspection requirements 15 Acceptance tests . 15 4.3.1Periodic tests . 16 4.3.24.4 Procedures for quality conformance 17 Quality conformance inspection . 17 4.4.1Quality conformance and its maintenance 17 4.4.24.5 Test

21、and measurement procedures . 17 General . 17 4.5.1Schedule of basic test groupings for acceptance and periodic tests . 17 4.5.24.6 Specifications . 18 Specification structures . 18 4.6.1Sectional specification (SS) . 18 4.6.2Detail specification (DS) 18 4.6.3Blank detail specification (BDS) . 18 4.6

22、.4Blank detail specification pro-forma for SQMA connectors . 20 4.6.55 Marking . 24 5.1 Marking of component . 24 5.2 Marking and contents of package 25 Figure 1 Connector with pin-centre contact (for dimensions and key, see Table 1) . 7 Figure 2 Connector with socket-centre contact (for dimensions

23、andkey, see Table 2) 8 Figure 3 Gauge pins for socket-centre contact (for dimensions, see Table 3) . 9 Figure 4 Connector with pin-centre contact (for dimensions and key, see Table 4) . 10 Figure 5 Connector with socket-centre contact (for dimensions and key, see Table 5) . 11 BS EN 61169-45:2014IEC

24、 61169-45:2014 IEC 2014 3 Table 1 Dimensions of connector with pin-centre contact . 7 Table 2 Dimensions of connector with socket-centre contact 8 Table 3 Dimensions of gauge pins for socket-centre contact 9 Table 4 Dimensions of connector with pin-centre contact . 10 Table 5 Dimensions of connector

25、 with socket-centre contact 11 Table 6 Climatic categories 12 Table 7 Ratings and characteristics . 12 Table 8 Acceptance tests . 15 Table 9 Periodic tests 16 BS EN 61169-45:2014 6 IEC 61169-45:2014 IEC 2014 RADIO-FREQUENCY CONNECTORS Part 45: Sectional specification for SQMA series quick lock RF co

26、axial connectors 1 Scope This part of IEC 61169, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SQMA quick lock RF coaxial connectors. The connectors are normally used with 50 in microwave, telecommunication, wireles

27、s and other fields, connecting with RF cables or micro-strips. The operating frequency limit is up to 18 GHz. It describes the interface dimensions for general purpose connectors grade 2 and standard test connectors grade 0 with gauging information and the mandatory tests selected from IEC 61169-1,

28、applicable to all detail specifications relative to type SQMA connectors. This specification indicates the recommended performance characteristics to be considered when writing a DS and covers all tests schedules and inspection requirements for assessment levels M and H. 2 Normative references The f

29、ollowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61169-1:

30、2013, Radio-frequency connectors Part 1: Generic specification General requirements and measuring methods 3 Mating face and gauge information 3.1 Dimensions General connectors Grade 2 Connector with pin-centre contact (see Figure 1) 3.1.1Metric dimension are original dimensions. All undimensioned pi

31、ctorial configurations are for reference purpose only. BS EN 61169-45:2014IEC 61169-45:2014 IEC 2014 7 Figure 1 Connector with pin-centre contact (for dimensions and key, see Table 1) Table 1 Dimensions of connector with pin-centre contact Ref. mm Additional notes Min. Max. a 11,50 b 4,98 5,02 c 5,6

32、2 5,68 d 4,18 e 7,50 (6) g 0,00 0,25 h 0,00 0,25 j 2,54 k 0,30 m 1,27 p 1,70 2,00 r (7) s 0,90 0,94 (1) Mechanical and electrical reference plane. (2) Design and location of the seal ring are optional, but shall meet environmental requirements. (3) Chamfer. (4) No chamfer, undercut acceptable. (5) D

33、esign of spring is optional, but shall meet mechanical requirement. (6) Prefix locknut (maximal dimension). (7) Diameter is chosen to obtain a normal impedance of 50 and meet electrical and mechanical requirements. (1) (2) (3) (4) (3) (5) e g p h m j IEC 1822/14 dbcarksBS EN 61169-45:2014 8 IEC 6116

34、9-45:2014 IEC 2014 Connector with socket-centre contact (see Figure 2) 3.1.2Figure 2 Connector with socket-centre contact (for dimensions andkey, see Table 2) Table 2 Dimensions of connector with socket-centre contact Ref. mm Additional notes Min. Max. a 4,95 b 4,90 4,95 c 5,55 5,59 d 4,18 e 7,60 f

35、3,97 4,00 g 0,25 h 0,25 j 2,82 n 2,00 2,50 p 3,20 3,40 r (3) s (4) t 49o51oAngle (1) Mechanical and electrical reference plane. (2) Design of chamfer is optional, but shall meet mechanical requirements. (3) Diameters are chosen to obtain a normal impedance of 50 and meet electrical and mechanical re

36、quirements. (4) Design for slotting optional, and should meet electrical and mechanical requirements, when mating with 0,90 mm 0,94 mm pin. IEC 1823/14 da(1) e (2) f p n bcg srh j BS EN 61169-45:2014IEC 61169-45:2014 IEC 2014 9 3.2 Gauges Gauge pins for socket-centre contact (see Figure 3) 3.2.1Figu

37、re 3 Gauge pins for socket-centre contact (for dimensions, see Table 3) Table 3 Dimensions of gauge pins for socket-centre contact Gauge A Maximum material for sizing purposes Gauge B Minimum material for measurement of retention force Mass of gauge: 28 g +2 g Ref. mm mm Min. Max. Min. Max. a 0,940

38、0,945 0,899 0,902 b 0,76 1,14 1,27 1,90 Material: steel, polished. Surface roughness: Ra 0,4 m on the cylindrical surface of length b. Test procedure 3.2.2The gauge A shall be inserted into the socket-centre contact three times with a minimum depth of 0,76 mm. This is a sizing operation and should o

39、nly be carried out when the socket-centre contact is removed from the connector. After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain the mass of the gauge in a vertical downward position. The test also shall be carried out on connector when the socket-centr

40、e contact is not removed. IEC 1824/14 50 10 a R0,4 mm max. bBS EN 61169-45:2014 10 IEC 61169-45:2014 IEC 2014 3.3 Dimensions Standard test connectors Grade 0 Connector with pin-centre contact (see Figure 4) 3.3.1Figure 4 Connector with pin-centre contact (for dimensions and key, see Table 4) Table 4

41、 Dimensions of connector with pin-centre contact Ref. mm Additional notes Min. Max. a 11,50 b 4,98 5,00 c 5,62 5,68 d 4,10 4,13 e 7,50 (6) g 0,05 h 0,08 j 2,03 2,29 k 0,30 m 1,27 p 1,70 2,00 r 1,27 nominal (7) s 0,92 0,94 (1) Mechanical and electrical reference plane. (2) Design and location of the

42、seal ring are optional, but shall meet environmental requirements. (3) Chamfer. (4) No chamfer, undercut acceptable. (5) Design of spring is optional, but shall meet mechanical requirements performance. (6) Prefix locknut (maximal dimension). (7) Diameters are chosen to obtain a normal impedance of

43、50 0,5 and meet electrical and mechanical requirements. IEC 1825/14 0,013 mm A A 0,025 mm B 0,013 mm B A (1) (2) (3) (4) e dbcag p h m j ksr(3) (5) BS EN 61169-45:2014IEC 61169-45:2014 IEC 2014 11 Connector with socket-centre contact (see Figure 5) 3.3.2Figure 5 Connector with socket-centre contact

44、(for dimensions and key, see Table 5) Table 5 Dimensions of connector with socket-centre contact Ref. mm Additional notes Min. Max. a 4,95 b 4,92 4,95 c 5,55 5,56 d 4,10 4,13 e 7,60 f 3,97 4,00 g 0,05 h 0,08 j 2,82 n 2,00 2,20 p 3,20 3,40 r 1,27 nominal (3) s (4) t 49o51o(1) Mechanical and electrica

45、l reference plane. (2) Design of chamfer is optional, but shall meet mechanical requirements. (3) Diameters are chosen to obtain a normal impedance of 50 0,5 . (4) Design for slotting optional, and should meet electrical and mechanical requirements when mating with 0,92 mm 0,94 mm pin. IEC 1826/14 0

46、,013 mm A A 0,025 mm B 0,013 mm A (1) (2) e dbcag p h n j rsf BS EN 61169-45:2014 12 IEC 61169-45:2014 IEC 2014 4 Quality assessment procedure 4.1 General The subclauses of this Clause 4 provide recommended ratings, performance and test conditions to be considered when writing a detail specification

47、 (DS). They also provide an appropriate schedule of tests with minimum levels of conformance. 4.2 Ratings and characteristics The values indicated below in Tables 6 and 7 are recommended for type SQMA connectors and are given for the writer of the detail specification. They are applicable for the co

48、ndition when the connectors are fully mated. Certain tests will usually not be required. When these tests are required, appropriate values shall be entered in the detail specification at the discretion of the specification writer. Table 6 Climatic categories Category designation Letter Temperature r

49、ange Damp heat steady state 65/125/51 65 C to +125 C Table 7 Ratings and characteristics Ratings and characteristics Test method IEC 61169-1:2013 subclause Value Remarks, deviation from standard test method Electrical Nominal impedance 50 Frequency range DC to 18 GHz Or upper frequency limit of cable R

展开阅读全文
相关资源
  • BS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdfBS ISO IEC 29150-2011 Information technology Security techniques Signcryption《信息技术 安全技术 签密》.pdf
  • BS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdfBS ISO IEC 15408-1-2009 Information technology - Security techniques - Evaluation criteria for IT Security - Introduction and general model《信息技术 安全技术 IT安全评价准则 一.pdf
  • BS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdfBS ISO 7295-1988+A1-2014 Tyre valves for aircraft Interchangeability dimensions《飞机轮胎汽门嘴 互换性尺寸》.pdf
  • BS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdfBS ISO 15118-1-2013 Road vehicles Vehicle to grid communication interface General information and use-case definition《道路车辆 车辆到电力通讯接口 通用信息和使用案例定义》.pdf
  • BS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdfBS ISO 13765-2-2004 Refractory mortars - Determination of consistency using the reciprocating flow table method《耐熔灰浆 使用往复流动表法测定一致性》.pdf
  • BS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdfBS ISO 10998-2008+A1-2014 Agricultural tractors Requirements for steering《农业拖拉机 操纵要求》.pdf
  • BS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdfBS Z 9-1998 Space data and information transfer systems - Advanced orbiting systems - Networks and data links - Architectural specification《空间数据和信息传输系统 高级轨道系统 网络和数据链接 结构规范》.pdf
  • BS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdfBS Z 7-1998 Space data and information transfer systems - ASCII encoded English《空间数据和信息传输系统 ASCII 编码英语》.pdf
  • BS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdfBS Z 5-1997 Space data and information transfer systems - Standard formatted data units - Control authority procedures《航天数据和信息发送系统 标准格式数据单元 控制授权程序》.pdf
  • BS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdfBS Z 4-1997 Space data and information transfer systems - Standard formatted data units - Structure and construction rules《航天数据和信息传输系统 标准格式数据单元 结构和构造规则》.pdf
  • 猜你喜欢
    相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > BS

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1