1、BS EN ISO3452-5:2008ICS 19.100,NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDNon-destructive testing Penetrant testingPart 5: Penetrant testing attemperatures higher than 50 degrees C(ISO 3452-5:2008)Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06
2、/2009 02:49, Uncontrolled Copy, (c) BSIThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 28 February2009 BSI 2009ISBN 978 0 580 57159 6Amendments/corrigenda issued since publicationDate CommentsBS EN ISO 3452-5:2008National forewordThis British Sta
3、ndard is the UK implementation of EN ISO 3452-5:2008.The UK participation in its preparation was entrusted to TechnicalCommittee WEE/46, Non-destructive testing.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to inclu
4、de all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.It is identical to ISO 3452-5:2008.Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Cop
5、y, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 3452-5December 2008ICS 19.100English VersionNon-destructive testing - Penetrant testing - Part 5: Penetranttesting at temperatures higher than 50 degrees C (ISO 3452-5:2008)Essais non destructifs - Examen par ressuage - Partie 5:Examen
6、par ressuage des tempratures supriures 50degrs C (ISO 3452-5:2008)Zerstrungsfreie Prfung - Eindringprfung - Teil 5:Eindringprfung bei Temperaturen ber 50 Grad C (ISO3452-5:2008)This European Standard was approved by CEN on 8 November 2008.CEN members are bound to comply with the CEN/CENELEC Internal
7、 Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.Th
8、is European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are th
9、e national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland
10、and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 3452
11、-5:2008: ELicensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008EN ISO 3452-5:2008 (E) 3 Foreword This document (EN ISO 3452-5:2008) has been prepared by Technical Committee CEN/TC 138 “Non-destructive testing“, the secretariat of whi
12、ch is held by AFNOR, in collaboration with Technical Committee ISO/TC 135 “Non-destructive testing“. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2009, and conflicting national standards s
13、hall be withdrawn at the latest by June 2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Re
14、gulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Ne
15、therlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008ISO 3452-5:2008(E) ISO 2008 All rights reserved iiiForeword ISO
16、 (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical com
17、mittee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrot
18、echnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the mem
19、ber bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identify
20、ing any or all such patent rights. ISO 3452-5 was prepared by the European Committee for Standardization (CEN) Technical Committee CEN/TC 138, Non-destructive testing, in collaboration with ISO Technical Committee TC 135, Non-destructive testing, Subcommittee SC 2, Surface methods, in accordance wit
21、h the Agreement on technical cooperation between ISO and CEN (Vienna Agreement). ISO 3452 consists of the following parts, under the general title Non-destructive testing Penetrant testing: Part 1: General principles Part 2: Testing of penetrant materials Part 3: Reference test blocks Part 4: Equipm
22、ent Part 5: Penetrant testing at temperatures higher than 50 C Part 6: Penetrant testing at temperatures lower than 10 C Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008ISO 3452-5:2008(E) iv ISO 2008 All rights reservedIntroduct
23、ion Temperatures higher than 50 C can affect the properties of penetrant test materials. The use of penetrant materials and the testing of penetrant materials within the temperature range 10 C to 50 C are the subject of EN 571-1 and ISO 3452-2. This part of ISO 3452 addresses materials and their use
24、 at higher temperatures. This part of ISO 3452 introduces the concept of process times being linked to working temperatures and accordingly users are recommended to ensure that testing products are correctly associated with process parameters in written instructions (procedures). Testing products ma
25、y be specifically developed and qualified for high temperature use but testing products qualified for use at normal temperatures, in some cases, may also be suitable for higher temperature use. This part of ISO 3452 was prepared with the assistance of ISPESL (Italy), whose laboratory performed resea
26、rch activity to verify the possibility of using penetrant at temperatures higher than 50 C, up to 200 C. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008INTERNATIONAL STANDARD ISO 3452-5:2008(E) ISO 2008 All rights reserved 1Non
27、-destructive testing Penetrant testing Part 5: Penetrant testing at temperatures higher than 50 C 1 Scope This part of ISO 3452 specifies the testing requirements particular to applications at higher temperatures (over 50 C) and also the method for qualification of suitable testing products. It appl
28、ies only to materials qualified for the relevant temperature range used in accordance with the manufacturers instructions. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undat
29、ed references, the latest edition of the referenced document (including any amendments) applies. ISO 3059, Non-destructive testing Penetrant testing and magnetic particle testing Viewing conditions ISO 3452-1, Non destructive testing Penetrant testing Part 1: General principles ISO 3452-2, Non-destr
30、uctive testing Penetrant testing Part 2: Testing of penetrant materials ISO 3452-3, Non-destructive testing Penetrant testing Part 3: Reference test blocks ISO 12706, Non-destructive testing Terminology Terms used in penetrant testing ISO/TS 18173, Non destructive testing General terms and definitio
31、ns 3 Terms and definitions For the purposes of this document, the terms and definitions given in ISO/TS 18173 and ISO 12706 apply. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008ISO 3452-5:2008(E) 2 ISO 2008 All rights reserved
32、4 High temperature penetrant testing requirements Penetrant materials shall be qualified, type tested for the temperature range within which the test temperature is included. The general principles as defined in ISO 3452-1 shall apply unless otherwise stated in this part of ISO 3452 or in the manufa
33、cturers instructions. The manufacturers instructions shall be followed. 5 Safety precautions Equipment and testing products shall be handled, stored and used in a safe manner and always in accordance with the manufacturers instructions. The viewing conditions required in this part of ISO 3452 are th
34、e same as those for the 10 C up to 50 C temperature range and the same safety precautions should be observed. In addition to the safety considerations associated with 10 C up to 50 C temperature range, due consideration shall be given to the risks associated with use at higher temperatures. Skin-bur
35、ning, flammability and volatility are examples of potential hazards which vary with temperature. The work area shall always be adequately ventilated and personnel exposure levels should be carefully assessed. All relevant European, national and local regulations pertaining to health and safety, envi
36、ronmental requirements etc. shall be observed. 6 Personnel qualification Personnel carrying out testing in accordance with this part of ISO 3452 shall be suitably certified (e.g. ISO 9712, EN 473). They shall also be knowledgeable of the special considerations for testing at higher temperatures (e.g
37、. time limitations for inspection, special considerations of materials). 7 Classification of testing products Testing products shall be classified by type, method and form as given in ISO 3452-2:2006, Table 1, but high temperature sensitivity shall be as described herein. Products also classified an
38、d qualified for 10 C up to 50 C temperature range may be designated with a suffix to show suitability for use at temperatures above 50 C, e.g. Type I, Method C, Form a, Level 2, Temperature M, (ICa-2/M). 8 General characteristics of the products The reference products as stated in 14.2 are penetrant
39、 materials used in the range 10 C to 50 C for comparison purposes (see 14.3) and they shall conform with the requirements of ISO 3452-2. Thermal stability shall be stated by the manufacturer and the test shall be carried out at least at 20 C above the maximum rated working temperature for the candid
40、ate testing material. Testing products shall be selected according to application with appropriate reference to the manufacturers recommendations for process parameters. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008ISO 3452-5
41、:2008(E) ISO 2008 All rights reserved 39 Reference blocks Temperature designation shall be performed with defined reference blocks (see e.g. Annex A of this part of ISO 3452 or ISO 3452-3, Type 1). Before use, reference blocks shall be cleaned using suitable means and tested for absence of indicatio
42、ns with a suitable non-aqueous wet developer. Absence of indications confirms that the panel is suitable for use. The developer shall be removed and the panel shall not be touched by bare hands throughout the process (to avoid contamination). Clean, white cotton, or other materials meant for tempera
43、ture-rating gloves, may be used to assist with handling. Annex A comparators shall be used only once and in matched pairs. One of them shall be tested at the temperature given in Clause 12 and the other one shall be tested at ambient temperature using penetrant materials suitable for use at 10 C to
44、50 C, (see Clause 8). NOTE High temperature process of Type 1 panels could lead to some residues being difficult to remove from the cracks. Specific care needs to be taken to maintain the usability of the panels. 10 Equipment Testing at higher temperatures requires additional equipment to that detai
45、led in ISO 3452-2, specifically, a) a thermostatic cell: capable of achieving a stable temperature at least 50 C above the maximum testing temperature, b) gloves suitable for that temperature, c) a brush suitable for that temperature, and d) a surface thermometer (contact type): 5 C error of indicat
46、ion of a measuring instrument. 11 Viewing conditions Viewing conditions shall comply with the requirements of ISO 3059. 12 Test temperature Temperature ratings and test points are shown in Table 1. For materials with a working temperature range of more than 50 C, testing shall be carried out at maxi
47、mum intervals of 50 C. Testing shall be carried out at the temperatures shown in Table 1. Table 1 Test temperatures Temperature rating Permitted range Test point temperature Tolerance M: Medium temperature 50 C to 100 C 50 C and 100 C 5 C H: High temperature 100 C to 200 C 100 C, 150 C and 200 C 5 C
48、 A, B: Range as specified by manufacturer A C to B C A C; B C and 50 C intervals 5 C Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 04/06/2009 02:49, Uncontrolled Copy, (c) BSIBS EN ISO 3452-5:2008ISO 3452-5:2008(E) 4 ISO 2008 All rights reserved13 Procedure for qualification Qualification t
49、ests are carried out by the manufacturer and if products are used within the stated range, no further tests are needed on site. Testing products shall be at room temperature prior to application, unless otherwise stated by the manufacturer. During the procedure detailed below the test block temperature shall not fall by more than 10 C. NOTE A metal block at test temperature can be used as a heat reservoir. a) Select, according to Clause 12, the test poin