CLC TR 62453-509-2009 Field device tool (FDT) interface specification - Part 509 Communication implementation for common object model - IEC 61784 CPF 9《现场装置工具(FDT)接口规范 第509部分 公共对象模.pdf

上传人:confusegate185 文档编号:629560 上传时间:2018-12-22 格式:PDF 页数:28 大小:1.79MB
下载 相关 举报
CLC TR 62453-509-2009 Field device tool (FDT) interface specification - Part 509 Communication implementation for common object model - IEC 61784 CPF 9《现场装置工具(FDT)接口规范 第509部分 公共对象模.pdf_第1页
第1页 / 共28页
CLC TR 62453-509-2009 Field device tool (FDT) interface specification - Part 509 Communication implementation for common object model - IEC 61784 CPF 9《现场装置工具(FDT)接口规范 第509部分 公共对象模.pdf_第2页
第2页 / 共28页
CLC TR 62453-509-2009 Field device tool (FDT) interface specification - Part 509 Communication implementation for common object model - IEC 61784 CPF 9《现场装置工具(FDT)接口规范 第509部分 公共对象模.pdf_第3页
第3页 / 共28页
CLC TR 62453-509-2009 Field device tool (FDT) interface specification - Part 509 Communication implementation for common object model - IEC 61784 CPF 9《现场装置工具(FDT)接口规范 第509部分 公共对象模.pdf_第4页
第4页 / 共28页
CLC TR 62453-509-2009 Field device tool (FDT) interface specification - Part 509 Communication implementation for common object model - IEC 61784 CPF 9《现场装置工具(FDT)接口规范 第509部分 公共对象模.pdf_第5页
第5页 / 共28页
点击查看更多>>
资源描述

1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationField device tool (FDT) interfacespecification Part 509: Communication implementation for common object model IEC 61784 CPF 9PD CLC/TR 62453-509:2009National forewordThis Publish

2、ed Document is the UK implementation of CLC/TR 62453-509:2009.The UK participation in its preparation was entrusted to Technical CommitteeAMT/7, Industrial communications: process measurement and control, includ-ing fieldbus.A list of organizations represented on this committee can be obtained onreq

3、uest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2010ISBN 978 0 580 62573 2ICS 25.040.40; 35.100.05; 35.110Compliance with a British Standard cannot confer immunity fromlegal obligatio

4、ns.This Published Document was published under the authority of theStandards Policy and Strategy Committee on 31 January 2010Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDPD CLC/TR 62453-509:2009TECHNICAL REPORT CLC/TR 62453-509 RAPPORT TECHNIQUE TECHNISCHER BERICHT N

5、ovember 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any mean

6、s reserved worldwide for CENELEC members. Ref. No. CLC/TR 62453-509:2009 E ICS 25.040.40; 35.100.05; 35.110 English version Field device tool (FDT) interface specification - Part 509: Communication implementation for common object model - IEC 61784 CPF 9 (IEC/TR 62453-509:2009) Spcification des inte

7、rfaces des outils des dispositifs de terrain (FDT) - Partie 509: Implmentation des communications pour le modle objet commun - CEI 61784 CPF 9 (CEI/TR 62453-509:2009) Field Device Tool (FDT)-Schnittstellenspezifikation - Teil 509: Kommunikationsimplementierung mit dem allgemeinen Objektmodell (COM)

8、-Kommunikationsprofilfamilie (CPF) 9 nach IEC 61784 (IEC/TR 62453-509:2009) This Technical Report was approved by CENELEC on 2009-10-01. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany,

9、 Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. PD CLC/TR 62453-509:2009CLC/TR 62453-509:2009 - 2 - Foreword The text of document 65E/70/CDV, fu

10、ture edition 1 of IEC/TR 62453-509, prepared by SC 65E, Devices and integration in enterprise systems, of IEC TC 65, Industrial-process measurement, control and automation, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as CLC/TR 62453-509 on 2009-10-01. This standard is

11、to be used in conjunction with EN 62453-3xy series. Annex ZA has been added by CENELEC. _ Endorsement notice The text of the Technical Report IEC/TR 62453-509:2009 was approved by CENELEC as a Technical Report without any modification. In the official version, for Bibliography, the following note ha

12、s to be added for the standard indicated: IEC 61784-1 NOTE Harmonized as EN 61784-1:2008 (not modified). _ PD CLC/TR 62453-509:2009- 3 - CLC/TR 62453-509:2009 Annex ZA (normative) Normative references to international publications with their corresponding European publications The following referenc

13、ed documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modi

14、fications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 62453-1 2009 Field device tool (FDT) interface specification - Part 1: Overview and guidance EN 62453-1 2009 IEC 62453-2 2009 Field device tool (FDT) interface specification - Part 2: Concepts and detail

15、ed description EN 62453-2 2009 IEC/TR 62453-41 2009 Field device tool (FDT) interface specification - Part 41: Object model integration profile - Common object model CLC/TR 62453-41 2009 IEC 62453-309 2009 Field device tool interface specification - Part 309: Communication profile integration - IEC

16、61784 CPF 9 EN 62453-309 2009 _ PD CLC/TR 62453-509:2009 2 TR 62453-509 IEC:2009(E) CONTENTS INTRODUCTION.5 1 Scope.6 2 Normative references .6 3 Terms, definitions, symbols, abbreviated terms and conventions 6 3.1 Terms and definitions 6 3.2 Symbols and abbreviated terms.6 3.3 Conventions 7 3.3.1 D

17、ata type names and references to data types 7 3.3.2 Vocabulary for requirements7 4 Bus category 7 5 Access to instance and device data7 6 Protocol specific usage of general data types.7 7 Protocol specific common data types8 8 Network management data types8 8.1 General .8 8.2 HART device address8 9

18、Communication data types FDTHARTCommunicationSchema .8 10 Channel parameter data types FDTHARTChannelParameterSchema 11 11 Device identification .14 11.1 Device type identification data types FDTHARTIdentSchema .14 11.2 Topology scan data types DTMHARTDeviceSchema 14 11.3 Scan identification data ty

19、pes FDTHARTScanIdentSchema15 11.4 Device type identification data types FDTHARTDeviceIdentSchema.16 11.5 XSLT Transformation 17 Bibliography24 Figure 1 Part 509 of the IEC 62453 series .5 Table 1 Protocol specific usage of general data types7 PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 5 INTROD

20、UCTION This part of IEC 62453 is an interface specification for developers of FDT (Field Device Tool) components for function control and data access within a client/server architecture. The specification is a result of an analysis and design process to develop standard interfaces to facilitate the

21、development of servers and clients by multiple vendors that need to interoperate seamlessly. With the integration of fieldbusses into control systems, there are a few other tasks which need to be performed. In addition to fieldbus- and device-specific tools, there is a need to integrate these tools

22、into higher-level system-wide planning- or engineering tools. In particular, for use in extensive and heterogeneous control systems, typically in the area of the process industry, the unambiguous definition of engineering interfaces that are easy to use for all those involved is of great importance.

23、 A device-specific software component, called DTM (Device Type Manager), is supplied by the field device manufacturer with its device. The DTM is integrated into engineering tools via the FDT interfaces defined in this specification. The approach to integration is in general open for all kind of fie

24、ldbusses and thus meets the requirements for integrating different kinds of devices into heterogeneous control systems. Figure 1 shows how IEC/TR 62453-509 is aligned in the structure of IEC 62453 series. Part 509Communicationimplementationfor common object model IEC 61784 CPF 9Figure 1 Part 509 of

25、the IEC 62453 series PD CLC/TR 62453-509:2009 6 TR 62453-509 IEC:2009(E) FIELD DEVICE TOOL (FDT) INTERFACE SPECIFICATION Part 509: Communication implementation for common object model IEC 61784 CPF 9 1 Scope IEC/TR 62453-509, which is a technical report, provides information for integrating the HART

26、1technology into the FDT interface specification (IEC 62453-2). This part of IEC 62453 specifies communication and other services. This specification neither contains the FDT specification nor modifies it. 2 Normative references The following referenced documents are indispensable for the applicatio

27、n of this specification. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies IEC 62453-1:2009, Field Device Tool (FDT) interface specification Part 1: Overview and guidance IEC 62453-2:2009, Fi

28、eld Device Tool (FDT) interface specification Part 2: Concepts and detailed description IEC/TR 62453-41:2009, Field Device Tool (FDT) interface specification Part 41: Object model integration profile Common object model IEC 62453-309:2009, Field Device Tool (FDT) interface specification Part 309: Co

29、mmunication profile integration IEC 61784 CPF 9 3 Terms, definitions, symbols, abbreviated terms and conventions 3.1 Terms and definitions For the purpose of this document, the terms and definitions given in IEC 62453-1, IEC 62453-2, and IEC/TR 62453-41 apply. 3.2 Symbols and abbreviated terms For t

30、he purpose of this document, the symbols and abbreviations given in IEC 62453-1, IEC 62453-2, and IEC/TR 62453-41 apply. 1HART is the trade name of the product supplied by HART Communication Foundation. This information is given for convenience of users of this document and does not constitute an en

31、dorsement by IEC of the product named. Equivalent products may be used if they can be shown to lead to the same results. PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 7 3.3 Conventions 3.3.1 Data type names and references to data types The conventions for naming and referencing of data types are

32、explained in IEC 62453-2 Clause A.1 3.3.2 Vocabulary for requirements The following expressions are used when specifying requirements. Usage of “shall” or “Mandatory” No exceptions allowed. Usage of “should” or “Recommended” Strong recommendation. It may make sense in special exceptional cases to di

33、ffer from the described behaviour. Usage of “can or “Optional Function or behaviour may be provided, depending on defined conditions. 4 Bus category IEC 61784 CPF 9 protocol is identified in the attribute busCategory of the BusCategory element by the identifiers, as specified in IEC 62453-309. 5 Acc

34、ess to instance and device data Used at methods: IDtmParameter:GetParameters() IDtmParameter:SetParameters() These methods shall provide access to at least to all parameters defined in IEC 62453-309. 6 Protocol specific usage of general data types Table 1 shows how general data types are used with I

35、EC 61784 CPF 9 devices. Table 1 Protocol specific usage of general data types Attribute Description for use fdt:address fdt:protocolId fdt:deviceTypeId fdt:deviceTypeInformation fdt:deviceTypeInformationPath fdt:manufacturerId fdt:semanticId fdt:applicationDomain fdt:tag All these attributes of the

36、FDTDatatype schema are used as defined in IEC 62453-309. PD CLC/TR 62453-509:2009 8 TR 62453-509 IEC:2009(E) 7 Protocol specific common data types This clause specifies the protocol specific common data types, which are used in the definition of other data types. The data types described in this cla

37、use are defined for following namespace: Namespace: 8 Network management data types 8.1 General The data types specified in this clause are used at following methods: IDtmParameter:GetParameters IDtmParameter:SetParameters 8.2 HART device address The element (defined in IEC/TR 62453-41) is used for

38、defining the network address of a device. 9 Communication data types FDTHARTCommunicationSchema The data types specified in this clause are used with the methods of IFdtCommunication. The definition of the attribute follows the data type definition as defined in IEC 62453-309. PD CLC/TR 62453-509:20

39、09TR 62453-509 IEC:2009(E) 9 PD CLC/TR 62453-509:2009 10 TR 62453-509 IEC:2009(E) Example: Examples for IEC 61784 CPF 9 burst mode The request from the DeviceDTM: PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 11 Answer if the device is already in burst mode: Receiving a burst frame: Unsubscribing

40、: Answer to unsubscribe: 10 Channel parameter data types FDTHARTChannelParameterSchema The XML document describes a how to access an IO value via an IEC 61784 CPF 9 command. The definition of the attributes and elements follows the definition of channel parameter data types as defined in IEC 62453-3

41、09. The data types specified in this clause are used with the following methods: IFdtChannel:GetChannelParameters() IFdtChannel:SetChannelParameters() PD CLC/TR 62453-509:2009 12 TR 62453-509 IEC:2009(E) PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 13 Example: PD CLC/TR 62453-509:2009 14 TR 6245

42、3-509 IEC:2009(E) 11 Device identification 11.1 Device type identification data types FDTHARTIdentSchema The HARTIdentSchema provides elements and attributes with a protocol specific semantic as well as document nodes without such a mapping (data type definition in IEC 62453-309). 11.2 Topology scan

43、 data types DTMHARTDeviceSchema Used at IDtmEvents:OnScanResponse() The XML document describes one entry in the list of scanned IEC 61784 CPF 9-Devices. PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 15 11.3 Scan identification data types FDTHARTScanIdentSchema This schema defines the XML document

44、 provided by a scan response of a CIP network. The schema defines attributes and elements that are used to provide protocol specific scanning. PD CLC/TR 62453-509:2009 16 TR 62453-509 IEC:2009(E) 11.4 Device type identification data types FDTHARTDeviceIdentSchema This subclause defines data types th

45、at are used to protocol specific information for device types. The schema provides attributes and elements for providing protocol specific information for device types. PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 17 11.5 XSLT Transformation ?xml version=“1.0“? !- This file is created by FDTxxxI

46、dentTransformation.xsl after transformation of xxxDTMDeviceIdentificationInstance.xml - FDT xmlns=“x-schema:DTMDeviceTypeIdentSchema.xml“ xmlns:ident=“x-schema:DTMIdentSchema.xml“ xmlns:fdt=“x-schema:FDTDataTypesSchema.xml“ PD CLC/TR 62453-509:2009 18 TR 62453-509 IEC:2009(E) /FDT ?xml version=“1.0“

47、? !- This file is created by FDTxxxIdentTransformation.xsl after transformation of xxxDTMScanIdentificationInstance.xml -FDT xmlns=“x-schema:DTMScanIdentSchema.xml“ xmlns:ident=“x-schema:DTMIdentSchema.xml“ xmlns:fdt=“x-schema:FDTDataTypesSchema.xml“ /FDT PD CLC/TR 62453-509:2009TR 62453-509 IEC:200

48、9(E) 19 Tag Device Identification Number Polling Address DeviceCommandRevisionLevel Device Revision Level DeviceCommandRevisionLevel Device Revision Level PD CLC/TR 62453-509:2009 20 TR 62453-509 IEC:2009(E) DeviceFlag Flags DeviceFlag Flags Manufacturer Identification Code Manufacturer Identificati

49、on Code HART HART PD CLC/TR 62453-509:2009TR 62453-509 IEC:2009(E) 21 HART Revision HART Revision Device Type Code Device Type Code Software Revision Software Revision Hardware Revision PD CLC/TR 62453-509:2009 22 TR 62453-509 IEC:2009(E) Hardware Revision ManufacturerSpecificExtension ManufacturerSpecificExtension ManufacturerSpecificExtension Manuf