1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Changes in accordance with NOR 5945-R001-93. 3 Dec 92 David E. Moore B Changed CAGE 63745 to 16170. Updated to current requirements of MIL-R-28750C. Changed 3.5, 3.6.3, 3.6.4, 3.6.5, 4, and figure 1. Editorial changes throughout. 1 Nov 95 D. Moore C Changes
2、 in accordance with NOR 5945- R008-00. 3 Apr 00 Kendall Cottongim D Validation and update. 25 Jul 03 K. Cottongim E Corrected part number for CAGE 16170. 24 Aug 05 Kendall Cottongim Prepared in accordance with ASME Y14.100 Selected item drawing REV PAGE REV PAGE REV D REV STATUS OF PAGES PAGES 1 PMI
3、C N/A PREPARED BYJames R. Martin CHECKED BYJames R. Martin APPROVED BYRichard A. Gosciniak SIZE A CODE IDENT. NO.Original date of drawing 8 February 1988 REV E CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43216-5000 AMSC N/A DISTRIBUT
4、ION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-D D D D D D D D E 2 3 4 5 6 7 8 9 10 DESIGN ACTIVITY DEFENSE ELECTRONICS SUPPLY CENTER DAYTON, OH 45444-5000 TITLE: RELAY, SOLID S
5、TATE, HERMETICALLY SEALED, ISOLATED, BI-DIRECTIONAL, 0.95 A, 60 V DC, ANALOG SIGNAL SWITCHING, SPST (N.O.), CMOS AND TTL CONTROL INPUTS 14933 DWG NO. 87042 PAGE 1 OF 10 5945-E125 1. SCOPE 1.1 Scope. This drawing describes the requirements for a hermetically sealed, solid state relay supplied to the
6、“Y“ screening requirements of MIL-PRF-28750. 1.2 Part or Identifying Number (PIN). The complete PIN shall be as follows: 87042 -001| | | | Drawing Dash number number 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and handbooks. The following specifications, standa
7、rds, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6
8、.3). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-PRF-28750 - Relays, Solid State, General Specification for. STANDARDS DEPARTMENT OF DEFENSE MIL-STD-202 - Test Method Standard Electronic and Electrical Component Parts. MIL-STD-750 - Test Method Standard for Semiconductor Devices. MIL-STD-883 - Test Met
9、hod Standard Microcircuits. (Unless otherwise indicated, copies of federal and military specifications, standards, and handbooks are available from the Document Automation and Production Service, Building 4D (DPM-DODSSP), 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In
10、the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. T
11、he individual item requirements shall be in accordance with MIL-PRF-28750, and as specified herein. 3.2 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-28750, and herein (see figure 1). DEFENSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DW
12、G NO. DAYTON, OH A 14933 87042 REV E PAGE 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Inches mm .002 .017 .02 .020 .110 .135 .190 .200 .273 .300 .470 .500 .530 .600 .850 .890 0.05 0.43 0.5 0.51 2.79 3.43 4.83 5.08 6.93 7.62 11.94 12.70 13.46 15
13、.24 21.59 22.61 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. Terminal numbers shown above are for reference only. 5. See table I and RSwhen VC 6 V. FIGURE 1. Outline drawing and dimens
14、ions. DEFENSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3 Input characteristics. -55C to +110C unless otherwise specified. 3.3.1 TTL (4-terminal confi
15、guration). See figure 1. 3.3.1.1 Input current. 16 mA dc maximum. 3.3.1.2 Voltage supply range. 3.8 V dc to 32 V dc max (see table l). 3.3.1.3 Rated turn-on voltage. 5.0 V dc. 3.3.1.4 Assured turn-off voltage. 1.5 V dc maximum. 3.3.1.5 Assured turn-on voltage. 3.8 V dc minimum. 3.3.1.6 Reverse polar
16、ity. -32 V dc maximum. 3.3.2 CMOS (5-terminal configuration/low power). See figure 1. 3.3.2.1 Control current. 3.3.2.1.1 At 5 V dc. 250 A maximum. 3.3.2.1.2 At 18 V dc. 1 mA maximum. 3.3.2.2 Control voltage range. 0 to 18 V dc. 3.3.2.3 Voltage supply range. 3.8 to 32 V dc (see table I). 3.3.2.4 Supp
17、ly current. 16 mA dc maximum. 3.3.2.5 Control turn-on voltage. 3.3.2.5.1 At -55C to +25C. 0.5 V dc maximum. 3.3.2.5.2 At +25C to +110C. 0.3 V dc maximum. 3.3.2.6 Control turn-off voltage. 3.3.2.6.1 At -55C to +25C. 3.2 V dc minimum. 3.3.2.6.2 At +25C to +110C. 2.8 V dc minimum. 3.3.2.7 Hysteresis. 1
18、.0 V minimum. (Not applicable for group A inspection). 3.4 Output characteristics. 3.4.1 Continuous operating output voltage. 60 V maximum. DEFENSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 4 Provided by IHSNot for ResaleNo reproduction or networking p
19、ermitted without license from IHS-,-,-3.4.2 Output leakage current. 3.4.2.1 At 60 V dc, -55C to +25C. 10 A maximum. 3.4.2.2 At 60 V dc, +25C to +110C. 100 A maximum. 3.4.2.3 At 35 V dc, +25C. 2 A maximum. 3.4.3 Output current. 0.95 A dc maximum at +25C. 3.4.4 Rated output current over temperature. S
20、ee figure 2. 3.4.5 Output capacitance. 200 pF maximum at 25 V dc, 1 MHz superimposed. 3.4.6 Input-output capacitance. 5 pF maximum, 1 kHz. 3.4.7 Transient voltage. 80 V dc maximum, 5 seconds maximum 1 mA at 80 V dc. 3.4.8 On resistance. 0.70 ohm maximum (measured at 100 mA at +25C). For on-resistanc
21、e at temperatures greater than +25C, use the following equation: TxexRR=006.025Where: R = Resistance at new junction temperature. R25 = Resistance at +25C junction temperature. T = (TJ- 25C). e = 2.7182818. 3.4.9 Output voltage drop. 1.2 V dc maximum. 3.4.10 Overload. 200 percent of rated current, 1
22、 second duration, 10 percent duty cycle. 3.5 Electrical characteristics. Unless otherwise specified, ambient temperature for electrical characteristics shall be -55C to +110C. 3.5.1 Dielectric withstanding voltage. 1,200 V ac maximum (input-to-output-to-case). 3.5.2 Insulation resistance. The insula
23、tion resistance from input to output, input to case, and output to case shall be 109ohms minimum. 3.5.3 Turn-on time (T(on). See figure 3. 3.5.3.1 At -55C to +25C. 3.0 milliseconds maximum. 3.5.3.2 At +25C to +110C. 6.0 milliseconds maximum. DEFENSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DWG
24、NO. DAYTON, OH A 14933 87042 REV E PAGE 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-TABLE I. Voltage supply range. V(C)range (volts) R(S) ohms Power rating watts 3.8 - 6 Not required Not required 6 - 10 300 .25 10 - 14 620 .25 14 - 18 910 .50 1
25、8 - 22 1,200 .50 22 - 26 1,500 .50 26 - 32 2,000 1 FIGURE 2. Thermal derating curves (free air) absolute maximum current versus ambient temperature. DEFENSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 6 Provided by IHSNot for ResaleNo reproduction or net
26、working permitted without license from IHS-,-,-3.5.4 Turn-off time (T(off). 4.0 milliseconds maximum (see figure 3). 3.5.5 Electromagnetic interferences. Not applicable. 3.5.6 Exponential rate of voltages rise. Not applicable. 3.6 Environmental characteristics. 3.6.1 Operating temperature range. -55
27、C to maximum per derating curve. 3.6.2 Storage temperature range. -55C to +125C. 3.6.3 Shock. MIL-STD-202, method 213, test condition G. 3.6.4 Vibration. MIL-STD-202, method 204, test condition D, 20 gs, 10 - 2,000 Hz. 3.6.5 Acceleration. MIL-STD-883, method 2001, test condition A, 5,000 gs, Y1. 3.6
28、.6 Seal. Hermetic seal shall be in accordance with MIL-PRF-28750. 3.6.7 Physical. Requirements shall be specified herein. 3.6.8 Weight. 5 grams maximum. 3.6.9 Wiring diagram. See figure 4. 3.7 Marking. Marking shall be in accordance with MIL-PRF-28750, except the relay shall be marked with the PIN a
29、s specified herein (see 1.2), the manufacturers name or Commercial and Government Entity (CAGE) code, and date lot codes. The M28750/X-XXXY PIN shall not be used. 3.8 Certificate of compliance. A certificate of compliance shall be required from manufacturers requesting to be a suggested source of su
30、pply. The certificate shall state that the manufacturers product meets all the requirements of this drawing. 3.9 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the
31、material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.10 Workmanship. The relay shall be uniform in quality and free from any defects that will affect life, serviceability, or appearance. DEFENSE ELECTRONICS SUPPLY CENTER S
32、IZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 7 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NOTE: Input transitions should be less than 1 millisecond duration. FIGURE 3. Turn-on and turn-off timing. FIGURE 4. Wiring diagram. DEFE
33、NSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. VERIFICATION 4.1 Product assurance program. The product assurance program specified in MIL-PRF-28750 is
34、 not applicable to this document. 4.2 Statistical process control. The statistical process control program specified in MIL-PRF-28750 is not applicable to this document. 4.3 Conformance inspection. 4.3.1 Inspection of product for delivery. Inspection of product for delivery shall consist of the grou
35、p A inspection of MIL-PRF-28750 for the Y screening level. Group A testing shall be performed on each inspection lot and manufacturers shall keep lot records for 3 years (minimum), monitor for compliance to the prescribed procedures, and records on lots are maintained for these relays. Components us
36、ed internally to the relay shall not require hermetic packaging. Temperature range for screening tests shall be as specified in 3.5 herein. 4.3.2 Inspection of packaging. Inspection of packaging shall be in accordance with MIL-PRF-28750. 4.4 Methods of inspection. Methods of inspection shall be in a
37、ccordance with MIL-PRF-28750. 5. PACKAGING 5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.3). When actual packaging of materiel is to be performed by DoD personnel, these personnel need to contact the responsible packaging ac
38、tivity to ascertain requisite packaging requirements. Packaging requirements are maintained by the Inventory Control Points packaging activity within the Military Department or Defense Agency, or within the Military Departments System Command. Packaging data retrieval is available from the managing
39、Military Departments or Defense Agencys automated packaging files, CD-ROM products, or by contacting the responsible packaging activity. 6. NOTES (This section contains information of a general or explanatory nature which may be helpful, but is not mandatory.) 6.1 Notes. Only definitions of the note
40、s specified in MIL-PRF-28750 will apply to this drawing. 6.2 Intended use. Relays conforming to this drawing are intended for use when military specifications do not exist and qualified military devices that will perform the required function are not available for OEM application. This drawing is in
41、tended exclusively to prevent the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a military specification exists and the product covered by this drawing has been qualified for listing on QPL-28750, this drawing will become inactive for new design. T
42、he QPL-28750 product shall be the preferred item for all applications. 6.3 Ordering data. The contract or purchase order should specify the following: a. Complete PIN (see 1.2). b. Requirements for delivery of one copy of the conformance inspection data or certificate of compliance that parts have p
43、assed conformance inspection with each shipment of parts by the manufacturer. c. Requirements for packaging and packing. 6.4 Replaceability. Relays covered by this drawing will replace the same generic devices covered by contractor-prepared specifications or drawings. DEFENSE ELECTRONICS SUPPLY CENT
44、ER SIZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-6.5 Users of record. Coordination of this document for future revisions are coordinated only with the suggested sources of supply and
45、 the users of record of this document. Requests to be added as a recorded user of this drawing should be in writing to: Defense Supply Center, Columbus, ATTN: DSCC/VAT, Post Office Box 3990, Columbus, OH 43216-5000 or by telephone (614) 692-0554 or DSN 850-0554. 6.6 Suggested sources of supply. Sugg
46、ested sources of supply are listed herein. Additional sources will be added as they become available. For assistance in the use of this drawing, contact Defense Supply Center, Columbus, ATTN: DSCC-VAT, Post Office Box 3990, Columbus, OH 43216-5000 or by telephone (614) 692-0554 or DSN 850-0554. DSCC
47、 drawing PIN Vendor similar designation or type number 1/ Vendor CAGE Vendor name and address 87042-001 686-2Y 16170 Teledyne Microelectronic Technologies 12964 Panama Street Los Angeles, CA 90066-6534 Phone (301) 574-2044 1/ Parts must be purchased to the DSCC PIN to assure that all performance requirements and tests are met. DEFENSE ELECTRONICS SUPPLY CENTER SIZE CODE IDENT NO. DWG NO. DAYTON, OH A 14933 87042 REV E PAGE 10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-