DLA MIL-R-28750 5 F-2009 RELAY SOLID STATE HERMETICALLY SEALED ISOLATED PLUS OR MINUS 50 MA PLUS OR MINUS 40 V AC OR DC ANALOG SIGNAL SWITCHING SPST (N O ).pdf

上传人:deputyduring120 文档编号:693166 上传时间:2018-12-30 格式:PDF 页数:5 大小:90.05KB
下载 相关 举报
DLA MIL-R-28750 5 F-2009 RELAY SOLID STATE HERMETICALLY SEALED ISOLATED PLUS OR MINUS 50 MA PLUS OR MINUS 40 V AC OR DC ANALOG SIGNAL SWITCHING SPST (N O ).pdf_第1页
第1页 / 共5页
DLA MIL-R-28750 5 F-2009 RELAY SOLID STATE HERMETICALLY SEALED ISOLATED PLUS OR MINUS 50 MA PLUS OR MINUS 40 V AC OR DC ANALOG SIGNAL SWITCHING SPST (N O ).pdf_第2页
第2页 / 共5页
DLA MIL-R-28750 5 F-2009 RELAY SOLID STATE HERMETICALLY SEALED ISOLATED PLUS OR MINUS 50 MA PLUS OR MINUS 40 V AC OR DC ANALOG SIGNAL SWITCHING SPST (N O ).pdf_第3页
第3页 / 共5页
DLA MIL-R-28750 5 F-2009 RELAY SOLID STATE HERMETICALLY SEALED ISOLATED PLUS OR MINUS 50 MA PLUS OR MINUS 40 V AC OR DC ANALOG SIGNAL SWITCHING SPST (N O ).pdf_第4页
第4页 / 共5页
DLA MIL-R-28750 5 F-2009 RELAY SOLID STATE HERMETICALLY SEALED ISOLATED PLUS OR MINUS 50 MA PLUS OR MINUS 40 V AC OR DC ANALOG SIGNAL SWITCHING SPST (N O ).pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 MIL-R-28750/5F 06 July 2009 SUPERSEDING MIL-R-28750/5E 23 June 2003 MILITARY SPECIFICATION SHEET RELAY, SOLID STATE, HERMETICALLY SEALED, ISOLATED, 50 MA, 40 V, AC OR DC, ANALOG SIGNAL SWITCHING, SPST (N. O.) This specification is approved for use by all Departments and Agencies of the Department o

2、f Defense. The requirements for acquiring the products described herein shall consist of this specification sheet and MIL-PRF-28750. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. Termin

3、al numbers shown above are for reference only. FIGURE 1. Outline drawing and dimensions. AMSC N/A FSC 5945 INCH-POUND MIL-R-28750/5 is inactive for new design after 16 June 1998 and is no longer used, except for replacement purposes. Ltr Inches mm Min Max Min Max A - .370 - 9.40 B - .335 - 8.51 C -

4、020 - 0.51 D - .280 - 7.11 E .500 - 12.70 - F .007 .027 0.18 0.68 G .021 .041 0.53 1.04 H .022 .042 0.56 1.07 J .090 .110 2.29 2.79 K .190 .210 4.83 5.33 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-28750/5F 2 REQUIREMENTS: INPUT DATA: Inpu

5、t voltage range: 4.0 to 7 V dc. 1/ Rated turn-on voltage: 5.0 V dc. 1/ Rated turn-off voltage: 1.0 V dc maximum. 1/ Input current: 22 mA dc maximum at rated voltage. Turn-on time: 10 microseconds maximum at rated voltage. Turn-off time: 15 microseconds maximum from rated voltage. Bias voltage: Not a

6、pplicable. OUTPUT DATA: Rated output current: See figure 2. Rated output voltage: 40 V, ac or dc. Output voltage drop: .5 V dc maximum at rated voltage. Output leakage current: 100 microamperes maximum at rated voltage. Crosstalk: Not applicable. Transient voltage: Not applicable. Electric system sp

7、ike: Not applicable. Overload: 1.5 x rating for 5 ms, 1 percent duty cycle. DC offset voltage: 10 millivolts. Waveform distortion: Not applicable. ELECTRICAL DATA: Dielectric withstanding voltage: 1,000 V ac (P-P), 60 Hz. Insulation resistance: 100 megohms. Isolation: 10 picofarads tested at 1 kHz.

8、 1/ Input must be a step function. Rise or fall time, as applicable, not to exceed 100 microseconds. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-28750/5F 3 Power dissipation: 140 milliwatts maximum at rated voltage. Reverse polarity (dc op

9、erated relays): Not applicable. ENVIRONMENTAL DATA: Temperature (operating and storage): -55C to +125C. Shock (specified pulse): MIL-STD-202, method 213, test condition F (1,500 Gs). Vibration: MIL-STD-202, method 204, test condition H, except peak value shall be 100 Gs (10 Hz to 2,000 Hz). Electrom

10、agnetic interference: Not applicable. Resistance to soldering heat: Applicable. Salt spray (corrosion): In accordance with MIL-STD-750, method 1041. Moisture resistance: Not applicable. PHYSICAL DATA: Terminal strength (MIL-STD-202, method 211): Pull test: Test condition A, 1 pound pull. Bend test:

11、Test condition C, 1/2 pound load. Twist test: Test condition D. Terminal solderability: Applicable. Dimensions and configuration: See figure 1. Weight: 5 grams (.18 ounce) typical. Seal: Hermetic. Terminal finish: Gold plated. LIFE TEST REQUIREMENTS: Life test: Group B and group C testing shall not

12、be performed. Minimum marking: Military PIN, functional diagram and terminal identification, date code, and manufacturers name or source code. Part or Identifying Number (PIN): M28750/5-001Y, M28750/5-001W and M28750/5-001X have been superseded by M28750/5-001Y. Provided by IHSNot for ResaleNo repro

13、duction or networking permitted without license from IHS-,-,-MIL-R-28750/5F 4 FIGURE 2. Output current versus input control voltage and ambient temperature. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-28750/5F 5 Referenced documents. In add

14、ition to MIL-PRF-28750, this document references the following: MIL-STD-202 MIL-STD-750 Changes from previous issue: Marginal notations are mark with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liabilit

15、y whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC

16、 Navy - EC Air Force - 85 DLA - CC (Project 5945-2009-013) Review activities: Army - AR, AT, CR4, MI Navy - AS, MC, OS, SH Air Force - 19, 99 NASA - NA NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 50131-8-2010 Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems German version EN 50131-8 2009《报警系统 侵入和拦截系统 第8部分 设备和系统用安全性》.pdf DIN EN 50131-8-2010 Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems German version EN 50131-8 2009《报警系统 侵入和拦截系统 第8部分 设备和系统用安全性》.pdf
  • DIN EN 50132-5-3-2013 Alarm systems - CCTV surveillance systems for use in security applications - Part 5-3 Video transmission - Analogue and digital video transmission German vers.pdf DIN EN 50132-5-3-2013 Alarm systems - CCTV surveillance systems for use in security applications - Part 5-3 Video transmission - Analogue and digital video transmission German vers.pdf
  • DIN EN 50134-1-2003 Alarm systems - Social alarm systems - Part 1 System requirements German version EN 50134-1 2002《报警系统 社会报警系统 第1部分 系统要求》.pdf DIN EN 50134-1-2003 Alarm systems - Social alarm systems - Part 1 System requirements German version EN 50134-1 2002《报警系统 社会报警系统 第1部分 系统要求》.pdf
  • DIN EN 50134-3-2012 Alarm systems - Social alarm systems Part 3 Local unit and controller German version EN 50134-3 2012《报警系统 社会报警系统 第3部分 局部装置和控制器 德文版本 EN 50134-3-2012》.pdf DIN EN 50134-3-2012 Alarm systems - Social alarm systems Part 3 Local unit and controller German version EN 50134-3 2012《报警系统 社会报警系统 第3部分 局部装置和控制器 德文版本 EN 50134-3-2012》.pdf
  • DIN EN 50134-5-2005 Alarm systems - Social alarm systems - Part 5 Interconnections and communications German version EN 50134-5 2004《警报系统 社会警报系统 第5部分 互连和通信》.pdf DIN EN 50134-5-2005 Alarm systems - Social alarm systems - Part 5 Interconnections and communications German version EN 50134-5 2004《警报系统 社会警报系统 第5部分 互连和通信》.pdf
  • DIN EN 50136-1-2012 Alarm systems - Alarm transmission systems and equipment - Part 1 General requirements for alarm transmission systems German version EN 50136-1 2012《报警系统 报警传输系统.pdf DIN EN 50136-1-2012 Alarm systems - Alarm transmission systems and equipment - Part 1 General requirements for alarm transmission systems German version EN 50136-1 2012《报警系统 报警传输系统.pdf
  • DIN EN 50143-2010 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V German versi.pdf DIN EN 50143-2010 Cables for signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 000 V but not exceeding 10 000 V German versi.pdf
  • DIN EN 50147-1-1996 Anechoic chambers - Part 1 Shield attenuation measurement German version EN 50147-1 1996《消声室 第1部分 屏蔽消声测量》.pdf DIN EN 50147-1-1996 Anechoic chambers - Part 1 Shield attenuation measurement German version EN 50147-1 1996《消声室 第1部分 屏蔽消声测量》.pdf
  • DIN EN 50148-1996 Electronic taximeters German version EN 50148 1995《出租车电子计价器》.pdf DIN EN 50148-1996 Electronic taximeters German version EN 50148 1995《出租车电子计价器》.pdf