1、 AMSC N/A FSC 5945 INCH-POUND MS25917H 16 March 2011 SUPERSEDING MS25917G 28 July 2009 DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 3 AMPERES, 4 PDT, TYPE I This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the
2、relay described herein shall consist of this specification sheet and MIL-PRF-6106. -1(SOLDER TERMINALS) -2(POTTED LEADS) FIGURE 1. Dimensions and configurations. INACTIVE FOR NEW DESIGN AFTER 2 MARCH 1987. NO SUPERSEDING STANDARD. Provided by IHSNot for ResaleNo reproduction or networking permitted
3、without license from IHS-,-,-MS25917H 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Terminal numbers do not appear on the relay header. There shall be affixed to the relay a suitable legible circuit diagram that identifies each terminal locati
4、on specified. Circuit diagram shown above is the terminal view. 4. In the event of a conflict between the text of this standard and the references cited herein, the text of this standard shall take precedence. 5. Referenced Government documents found on https:/assist.daps.dla.mil/quicksearch/ and sp
5、ecified in the solicitation or contract form a part of this specification sheet to the extent specified herein. 6. Unless otherwise specified, tolerance is .010 (0.25 mm). FIGURE 1. Dimensions and configurations - Continued. Inches mm Inches mm .010 0.25 .656 16.66 .060 1.52 .750 19.05.062 1.57 .812
6、 20.62 .093 2.36 1.000 25.40.112 2.84 1.130 28.70 .125 3.18 1.500 38.10.250 6.35 1.750 44.45 .375 9.53 2.187 55.55.500 12.70 6.000 152.40 .625 15.88 24.000 609.60Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25917H 3 REQUIREMENTS: Dimensions and
7、configuration: See figure 1. Weight: -1 .25 pounds (113 grams). -2 .50 pounds (227 grams). Contact requirements: Load ratings: High level (relay case grounded). Resistive: 3 amperes at 28 V dc, 115 V ac (400 Hz). Inductive: 1.5 amperes at 28 V dc, 115 V ac (400 Hz). Motor: 1.5 amperes at 28 V dc, 11
8、5 V ac (400 Hz). Mixed loads: Applicable. Coil requirements: Nominal coil voltage: 28 V dc. Pick up voltage: 18 V dc (over the temperature range). Hold voltage: 7.0 V dc (over the temperature range). Dropout voltage: 1.5 V dc (over the temperature range). Coil current: 0.15 ampere maximum. Electrica
9、l requirements: Insulation resistance (minimum): Initial: 100 megohms. After life or environmental test: 50 megohms. Dielectric strength: Sea level (V rms) Altitude (V rms) Initial After life 80,000 feet -1 -2 Coil to case: 1,000 1,000 250 500 All of the points: 1,000 1,000 250 500Provided by IHSNot
10、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25917H 4 Environmental requirements: Temperature range: -65C to +120C. Shock (specified pulse): Applicable, MIL-STD-202, method 213, test condition A, 25 gs, 6-9 milliseconds. Contact chatted shall no exceed 10 microse
11、conds maximum opening for closed contacts and 1 microsecond maximum closure for open contacts. Vibration (sinusoidal): Applicable, MIL-STD-202, method 204, test condition A, 10 gs or .036 DA whichever is less, from 5 to 500 Hz. Contact chatter shall not exceed 10 microseconds maximum opening for clo
12、sed contacts and 1 microsecond maximum closure for open contacts. Hermetically-sealed (potted) relay: Relays shall be tested as follows: a. Prior to installing a gasket on the relay header (if a gasket is used), the relay shall be totally immersed in a container of “tap” water. (The “tap” water as u
13、sed here means ordinary drinking water that has not been altered in any way, such as by the addition of any other substance or distilling). The part of the relay closest to the surface of the water shall be a minimum of 1 inch (25.4 mm) below this surface. b. The container and water-covered relay sh
14、all then be placed in a vacuum chamber. The chamber shall be sealed. The chamber pressure shall be reduced from room ambient to 0.82 inch (80,000 feet) +0.0 inch- 0.2 inch of mercury within 5 minutes, and shall be maintained at this level for 30 minutes minimum. The chamber pressure shall be increas
15、ed to room ambient within 1 minute, and shall be maintained at room ambient pressure for 30 minutes, minimum. The foregoing shall constitute one cycle. The relay shall remain fully immersed in the water during the cycle. c. Within a maximum of one-half hour after the cycle, each relay shall be remov
16、ed from the water and dried by shaking, wiping, or blowing with contaminant-free air or gas, but not by any form of heating or baking. d. Within a maximum of one-half hour after drying, each relay shall be subjected to the DWV and IR tests. Life test requirements 50,000 cycles minimum. Qualification
17、 by similarity: If the relay case, frame, or enclosure contains integral sealed electromagnetic relays (mounting means excepted) currently listed on the qualified products list of MIL-PRF-83536/5, reduced testing shall consist of subjecting four sample units to the shock and vibration requirements o
18、f this specification sheet. Post tests shall include insulation resistance, dielectric withstanding voltage and electrical characteristics, and seal. One unsealed unspotted unit shall be submitted to the qualifying activity. VERIFICATION: Group A: a. Group A1: Run-in. This subgroup may be waived by
19、the qualifying activity if fully tested sealed MIL-PRF-83536/5 relays are used internally. b. Group A2: 100 percent. c. Dielectric withstanding voltage: (1) Tests to be conducted at sea level rating only. (2) Duration of application: 5-10 seconds at a 10 percent increase in the dielectric strength v
20、oltage. Group A acceptance reports shall be submitted to the qualifying activity on a yearly basis in order to retain qualification for this detail specification sheet. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25917H 5 Group B and group C te
21、sting are not required. The manufacturer shall notify the qualifying activity in the event of any design or construction changes, and the qualifying activity may impose additional testing requirements as necessary. Part or identifying number: (PIN): MS25917-1 for solder terminals or MS25917-2 for po
22、tted leads. Referenced documents. In addition to MIL-PRF-6106, this document references the following: MIL-PRF-83536/5 MIL-STD-202 MIL-PRF-8516 MIL-DTL-8777 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue
23、 were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relat
24、ionship to the last previous issue. Custodian: Preparing activity: Navy - AS DLA - CC Air Force - 85 DLA - CC (Project 5945-2011-011) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-