DLA SMD-5962-13225-2013 MICROCIRCUIT HYBRID DIGITAL DUAL CHANNEL DRIVER-RECEIVER.pdf

上传人:王申宇 文档编号:698530 上传时间:2019-01-02 格式:PDF 页数:17 大小:187.56KB
下载 相关 举报
DLA SMD-5962-13225-2013 MICROCIRCUIT HYBRID DIGITAL DUAL CHANNEL DRIVER-RECEIVER.pdf_第1页
第1页 / 共17页
DLA SMD-5962-13225-2013 MICROCIRCUIT HYBRID DIGITAL DUAL CHANNEL DRIVER-RECEIVER.pdf_第2页
第2页 / 共17页
DLA SMD-5962-13225-2013 MICROCIRCUIT HYBRID DIGITAL DUAL CHANNEL DRIVER-RECEIVER.pdf_第3页
第3页 / 共17页
DLA SMD-5962-13225-2013 MICROCIRCUIT HYBRID DIGITAL DUAL CHANNEL DRIVER-RECEIVER.pdf_第4页
第4页 / 共17页
DLA SMD-5962-13225-2013 MICROCIRCUIT HYBRID DIGITAL DUAL CHANNEL DRIVER-RECEIVER.pdf_第5页
第5页 / 共17页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED REV SHEET REV SHEET 15 16 REV STATUS REV OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Greg Cecil DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Gr

2、eg Cecil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE APPROVED BY Charles F. Saffle MICROCIRCUIT, HYBRID, DIGITAL, DUAL CHANNEL, DRIVER-RECEIVER DRAWING APPROVAL DATE 13-12-17 AMSC N/A REVISION LEVEL SIZE A CAGE CODE 67268 5962-13225 SHEET 1 OF 16 DS

3、CC FORM 2233 APR 97 5962-E541-13 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This dra

4、wing documents five product assurance classes as defined in paragraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in t

5、he PIN. 1.2 PIN. The PIN shall be as shown in the following example: 5962 - 13225 01 H X A Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardnes

6、s assurance (RHA) designator. Device classes H and K RHA marked devices shall meet the MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows:

7、 Device type Generic number Circuit function 01 BU-67402 Dual channel, five volt, MIL-STD-1553 Transceiver/transformer combination 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements

8、of MIL-PRF-38534 and require QML Certification as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applic

9、ations. H Standard military quality class level. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible li

10、mited temperature range, manufacturer specified incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C, and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements o

11、f that class. These exception(s) must be specified in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the man

12、ufacturers internal, QML certified flow. This product may have a limited temperature range. 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIR

13、CUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL SHEET 3 DSCC FORM 2234 APR 97 Outline letter Descriptive designator Terminals Package style X See figure 1 36 Flat Package with ceramic tie bars Y See figure 1 36 Flat package with gull wing shaped leads. 1

14、.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Supply voltage range . -0.3 V dc to +7.0 V dc Logic input voltage range . -0.3 V dc to VCC+0.3 Storage temperature range -65C to +150C Power dissipation PD2/ 3/ 4/ 5/ 1.32 W Lead temperature (s

15、oldering, 10 seconds) +300C Thermal resistance, junction to case JC. 9C/W 3/ 1.4 Recommended operating conditions. 2/ Supply voltage range . +4.75 V dc to +5.25 V dc Logic input voltage range . 0.0 V dc to +VCCMinimum logic high input voltage (VIH) . 2.0 V dc Maximum logic low input voltage (VIL) 0.

16、8 V dc Receiver differential voltage direct coupled: Device type 01 1.2 Vp-pminimum Receiver differential voltage transformer coupled: Device type 01 0.860 Vp-pminimum Receiver common-mode voltage: Device type 01 10.0 VPEAK Driver peak output current . 700 mA Serial data rate 1.0 MHz maximum Case op

17、erating temperature range -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are thos

18、e cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. MIL-S

19、TD-1553 - Digital Time Division Command/Response Multiplex Data Bus 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2/ Normal operating conditions require one transceiver

20、on and the other off. 3/ Hottest die. 4/ Assumes 100 percent transmitter duty cycle on one channel and 0 percent duty cycle on the other channel. 5/ Applies up to TC = +125C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWI

21、NG SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL SHEET 4 DSCC FORM 2234 APR 97 DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at h

22、ttp:/quicksearch.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. No

23、thing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item performance requirements for device classes D, E, G, H, and K shall be in accordance with MIL-PRF-38534. Compliance wi

24、th MIL-PRF-38534 shall include the performance of all tests herein or as designated in the device manufacturers Quality Management (QM) plan or as designated for the applicable device class. The manufacturer may eliminate, modify or optimize the tests and inspections herein, however the performance

25、requirements as defined in MIL-PRF-38534 shall be met for the applicable device class. In addition, the modification in the QM plan shall not affect the form, fit, or function of the device for the applicable device class. 3.2 Design, construction, and physical dimensions. The design, construction,

26、and physical dimensions shall be as specified in MIL-PRF-38534 and herein. 3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.4 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.2.3 Pin functions. The pin functions

27、shall be as specified in table III. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.4 Electrical test requirements. The electri

28、cal test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.5 Marking of device(s). Marking of device(s) shall be in accordance with MIL-PRF-38534. The device shall be marked with the PIN listed in 1.2 herein. In addition, the

29、manufacturers vendor similar PIN may also be marked. 3.6 Data. In addition to the general performance requirements of MIL-PRF-38534, the manufacturer of the device described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group A lot

30、sample, for each device type listed herein. Also, the data should include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made available to the preparing activity

31、(DLA Land and Maritime -VA) upon request. 3.7 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance (original copy) submitted to DLA Land and Maritime -VA shall affirm that the manufacturers prod

32、uct meets the performance requirements of MIL-PRF-38534 and herein. 3.8 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of microcircuits delivered to this drawing. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspecti

33、on procedures shall be in accordance with MIL-PRF-38534 or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. 4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The fo

34、llowing additional criteria shall apply: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL SHEET 5 DSCC FORM 2234 APR 97 a. Burn-in test, met

35、hod 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to either DLA Land and Maritime -VA or the acquiring activity upon request. Also, the test circuit shall specify the i

36、nputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TAas specified in accordance with table I of method 1015 of MIL-STD-883. b. Interim and final electrical test parameters shall be as specified in table II herein,

37、except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-

38、3990 REVISION LEVEL SHEET 6 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ -55C TC +125C unless otherwise specified Group A subgroups Device type Limits Unit Min Max RECEIVER Output low voltage VOLIOL= 4.0 mA 2/ 1,2,3 01 0.4 V Output high voltage VOH

39、IOH= -2.4 mA 2/ 1,2,3 01 4.1 V Differential input level VI3/ 4,5,6 01 28.0 Vp-p Input common-mode voltage VICM3/ 4,5,6 01 10.0 V Differential Input Impedance ZDIN Direct coupled, 1 MHz sine wave 3/ 4,5,6 01 2.0 k Differential Input Impedance ZXINTransformer coupled, 1 MHz since wave 3/ 4,5,6 01 1.0

40、k Input capacitance CIN1 MHz sine-wave 3/ 4,5,6 01 10.0 pf Threshold voltage VDTHDirect coupled 4,5,6 01 0.280 1.2 Vp-p Threshold voltage VXTHTransformer coupled 4,5,6 01 0.200 0.860 Vp-p RECEIVER STROBE Input low voltage VSIL3/ 1,2,3 01 0.8 V Input high voltage VSIH3/ 1,2,3 01 2.0 V Input low curre

41、nt ISILVSIL= 0.0 V 1,2,3 01 -100 -2.0 A Input high current ISIHVSIH= VCC 1,2,3 01 -10 10 A See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS,

42、OHIO 43218-3990 REVISION LEVEL SHEET 7 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Conditions 1/ -55C TC +125C unless otherwise specified Group A subgroups Device type Limits Unit Min Max TRANSMITTER Input low voltage VIL3/ 1,2,3 01 0.8 V Input high

43、 voltage VIH3/ 1,2,3 01 2.0 V Input low current IILVIL= 0.0 V 1,2,3 01 -10 +10 A Input high current IIHVIH= VCC1,2,3 01 20 100 A Differential out voltage VO35 load 4,5,6 01 6.0 9.0 VP-P140 load 18 27 Differential out noise VONInhibited, transformer-coupled 3/ 4,5,6 01 14.0 mVRMSInhibited, direct-cou

44、pled 3/ 5.0 mVRMSOutput capacitance COUT1 MHz sine-wave 3/ 01 10 pf Differential offset voltage VOS35 load 4/ 4,5,6 01 90 mV pk 140 load 4/ 250 mVP-PRise time tR 35 load 9,10,11 01 100 300 ns 140 load Fall time tF35 load 9,10,11 01 100 300 ns 140 load See footnotes at end of table. Provided by IHSNo

45、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL SHEET 8 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics - Continued. Test Symbol Condi

46、tions 1/ -55C TC +125C unless otherwise specified Group A subgroups Device type Limits Unit Min Max TRANSMITTER INHIBIT Input low voltage VIIL3/ 1,2,3 01 0.8 V Input high voltage VIIH3/ 1,2,3 01 2.0 V Input low current IIILVIIL= 0.0 V 1,2,3 01 -10 10 A Input high current IIIHVIIH= 2.4 V 1,2,3 01 20

47、100 A POWER SUPPLY Supply current ICC1Standby 1,2,3 01 80 100 mA ICC225% duty cycle 4,5,6 01 200 229 mA ICC350% duty cycle 4,5,6 01 300 348 mA ICC4100% duty cycle 4,5,6 01 500 565 mA Power Dissipation PD Standby 3/ 01 0.40 0.50 W 25% duty cycle 3/ 0.66 0.81 50% duty cycle 3/ 0.75 1.06 100% duty cycl

48、e 3/ 0.92 1.32 See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-13225 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL SHEET 9 DSCC FORM 2234 APR 97 TABLE I. Electrical performance chara

展开阅读全文
相关资源
猜你喜欢
  • ANSI AAMI ISO 25539-3-2011 Cardiovascular implants.Endovascular devices.Part 3 Vena Cava Filters.pdf ANSI AAMI ISO 25539-3-2011 Cardiovascular implants.Endovascular devices.Part 3 Vena Cava Filters.pdf
  • ANSI AAMI ISO 27185-2012 Cardiac rhythm management devices.Symbols to be used with cardiac rhythm management device labels and information to be supplied.General nrequirements.pdf ANSI AAMI ISO 27185-2012 Cardiac rhythm management devices.Symbols to be used with cardiac rhythm management device labels and information to be supplied.General nrequirements.pdf
  • ANSI AAMI ISO 5840-3-2013 Cardiovascular implants - Cardiac valve prostheses - Part 3 Heart valve substitutes implanted by transcatheter techniques.pdf ANSI AAMI ISO 5840-3-2013 Cardiovascular implants - Cardiac valve prostheses - Part 3 Heart valve substitutes implanted by transcatheter techniques.pdf
  • ANSI AAMI ISO 8637-2010 A1-2013 Cardiovascular implants and extracorporeal systems - Haemodialysers haemodiafilters haemofilters and haemoconcentrators - Amendment 1 Revision to Fi.pdf ANSI AAMI ISO 8637-2010 A1-2013 Cardiovascular implants and extracorporeal systems - Haemodialysers haemodiafilters haemofilters and haemoconcentrators - Amendment 1 Revision to Fi.pdf
  • ANSI AAMI ISO 8637-2010 Cardiovascular implants and extracorporeal systems - Haemodialysers haemodiafilters haemofilters and haemoconcentrators《心血管植入物和人造器官.血液透析器 血液透析滤过器 血液滤过器和血液浓缩.pdf ANSI AAMI ISO 8637-2010 Cardiovascular implants and extracorporeal systems - Haemodialysers haemodiafilters haemofilters and haemoconcentrators《心血管植入物和人造器官.血液透析器 血液透析滤过器 血液滤过器和血液浓缩.pdf
  • ANSI AAMI ISO TIR 11135-2-2008 Sterilization of health care products - Ethylene oxide - Part 2 Guideance on the application of ANSI AAMI ISO 11135-1《卫生保健产品的消毒.环氧乙烷.第2部分 应用ANSI AAMI.pdf ANSI AAMI ISO TIR 11135-2-2008 Sterilization of health care products - Ethylene oxide - Part 2 Guideance on the application of ANSI AAMI ISO 11135-1《卫生保健产品的消毒.环氧乙烷.第2部分 应用ANSI AAMI.pdf
  • ANSI AAMI ISO TIR 17665-2-2009 Sterilization of health care products - Moist heat - Part 2 Guidance on the application of ANSI AAMI ISO 17665-1《保健品的杀菌.温湿.第2部分 标准ANSI AAMI ISO 17665.pdf ANSI AAMI ISO TIR 17665-2-2009 Sterilization of health care products - Moist heat - Part 2 Guidance on the application of ANSI AAMI ISO 17665-1《保健品的杀菌.温湿.第2部分 标准ANSI AAMI ISO 17665.pdf
  • ANSI AAMI ISO TIR10974-2012 Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device.pdf ANSI AAMI ISO TIR10974-2012 Assessment of the safety of magnetic resonance imaging for patients with an active implantable medical device.pdf
  • ANSI AAMI ISO TIR13004-2013 Sterilization of health care products - Radiation - Substantiation of a selected sterilization dose Method VDmaxSD.pdf ANSI AAMI ISO TIR13004-2013 Sterilization of health care products - Radiation - Substantiation of a selected sterilization dose Method VDmaxSD.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1