1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Make change to note 1 under figure 1. Update boilerplate paragraphs to current MIL-PRF-38535 requirements. - ro 11-08-03 C. SAFFLE REV SHET REV SHET REV STATUS REV A A A A A A A A A A OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 PMIC N/A PREPARED BY RICK

2、 C. OFFICER DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY CHARLES E. BESORE APPROVED BY MICHAEL A. FRYE MICROCIRCUIT, LINEAR, WIDEBAND AMPL

3、IFIER, MONOLITHIC SILICON DRAWING APPROVAL DATE 93-06-16 AMSC N/A REVISION LEVEL A SIZE A CAGE CODE 67268 5962-90521 SHEET 1 OF 10 DSCC FORM 2233 APR 97 5962-E260-11 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A

4、 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A. 1.2 Part or Identifyi

5、ng Number (PIN). The complete PIN is as shown in the following example: 5962-90521 01 X A Drawing number Device type (see 1.2.1) Case outline(see 1.2.2) Lead finish(see 1.2.3)1.2.1 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit functio

6、n 01 SL532 Wideband amplifier, low phase shift limiter 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 8 Can 1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535,

7、appendix A. 1.3 Absolute maximum ratings. Supply voltage ( VCC1, VCC2) +15 V dc Power dissipation (PD) 250 mW Junction temperature (TJ) . +175C Lead temperature (soldering, 10 seconds) +300C Storage temperature range . -65C to +150C Thermal resistance, junction-to-case (JC) . 60C/W Thermal resistanc

8、e, junction-to-ambient (JA) 210C/W 1.4 Recommended operating conditions. 1/ Supply voltage ( VCC1, VCC2) +9.0 V dc Frequency . 60 MHz Input voltage (VIN) 7.07 mVrms Bandwidth . 300 MHz Ambient operating temperature range (TA) . -55C to +125C _ 1/ All outputs may be shorted to ground. Provided by IHS

9、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handb

10、ooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits,

11、Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Stan

12、dard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text

13、of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in

14、 accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL

15、-PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modificati

16、ons shall not affect form, fit, or function of the device. These modifications shall not affect the PIN as described herein. A “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used. 3.2 Design, construction, and physical dimensions.

17、 The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535, appendix A and herein. 3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2. 3.3 El

18、ectrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full ambient operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups

19、 specified in table II. The electrical tests for each subgroup are described in table I. 3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. For packages where m

20、arking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the “5962-“ on the device. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance to MIL-PRF-38535, appendi

21、x A. The compliance indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SI

22、ZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 4 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ -55C TA+125C Group A subgroupsDevice type Limits 2/ Unit unless otherwise specified Min Max Supply current I+ No s

23、ignal 1,2,3 01 5 12 mA Small signal voltage gain AVS4,5,6 01 11 14 dB Gain variation with temperature AT4,5,6 01 3.0 dB Upper cut-off frequency fCU-3 dB with respect to 60 MHz gain 4,5,6 01 200 MHz Lower cut-off frequency fCL-3 dB with respect to 60 MHz gain 4,5,6 01 10 MHz Phase variation -30 dBm t

24、o +10 dBm 4 01 -3 +3 Degrees 5,6 -1 +1Limited output voltage VIN= 0.707 V rms 4 01 1.0 1.4 VPP5,6 -0.1 +0.1 1/ Unless otherwise specified, VCC1, VCC2= +9 V, f = 60 MHz, RL= 1 k, and RS= 50 , CL 5 pF. See figure 3. 2/ The algebraic convention, whereby the most negative value is a minimum and the most

25、 positive is a maximum, is used in this table. Negative current shall be defined as conventional current flow out of a device terminal. 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-1

26、03 (see 6.6 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an approved source of supply shall affirm that the manufacturers product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance. A ce

27、rtificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing. 3.8 Notification of change. Notification of change to DLA Land and Maritime -VA shall be required for any change that affects this drawing. 3.9 Verification a

28、nd review. DLA Land and Maritime, DLA Land and Maritimes agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the reviewer. Provided by IHSNot for Resale

29、No reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 5 DSCC FORM 2234 APR 97 Case X FIGURE 1. Case outline. Provided by IHSNot for ResaleNo reproduction or networkin

30、g permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 6 DSCC FORM 2234 APR 97 Case X Symbol Dimensions Notes Inches Millimeters Min Max Min Max A .165 .185 4.19 4.70 b .016 .019 0.41 0.48 3, 5,

31、7 b1 .016 .021 0.41 0.53 3, 5, 7 D .335 .370 8.51 9.40 D1 .305 .335 7.75 8.51 D2 .110 .160 2.79 4.06 F - .040 - 1.02 k .027 .034 0.69 0.86 k1 .027 .045 0.69 1.14 4 L .500 .750 12.70 19.05 3 L1 - .050 - 1.27 3 L2 .250 - 6.35 - 3 Case outline Symbol Note e e1 N X 45 BSC .200 BSC .100 BSC 8 5 1. The US

32、 government preferred system of measurement is the metric SI system. However, since this item was originally designed using inch-pound units of measurement, in the event of conflict between the metric and inch pound units, the inch pound units shall take precedence. 2. Metric equivalents are for gen

33、eral information only. 3. All leads: b applies between L1 and L2. b1 applies between L2 and .500 (12.70 mm) from the reference plane. Diameter is uncontrolled in L1 and beyond .500 (12.70 mm) from the reference plane. 4. Measured from maximum diameter of the product. 5. Leads having a maximum diamet

34、er .019 (0.48 mm) measured in gauging plane .054 (1.37 mm) + .001 (0.03 mm) - .000 (0.00 mm) below the base plane of the product shall be within .007 (0.18 mm) of their true position relative to a maximum width tab. 6. The product may be measured by direct methods or by gauge. 7. All leads: Increase

35、 maximum limit by .003 (0.08 mm) when lead finish A or B is applied. 8. The location, alpha, of the leads is 360/N. N is total number of leads or lead positions. FIGURE 1. Case outline Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDA

36、RD MICROCIRCUIT DRAWING SIZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 7 DSCC FORM 2234 APR 97 Device type 01 Case outline X Terminal number Terminal symbol 1 VCC12 BIAS 3 INPUT 4 INPUT GROUND 5 DECOUPLE (LF ONLY) (see note1) 6 OUTPUT (see note2) 7 OUTPUT GR

37、OUND 8 VCC2NOTES: 1, This pin is used to extend the low frequency (LF) response. 2. Load capacitance should be less than 5 pF including stray capacitance. FIGURE 2. Terminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROC

38、IRCUIT DRAWING SIZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 8 DSCC FORM 2234 APR 97 FIGURE 3. Test circuit. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-90521 DL

39、A LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 9 DSCC FORM 2234 APR 97 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. Screening shall be in accordance with method 5004 of MIL-

40、STD-883, and shall be conducted on all devices prior to quality conformance inspection. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level

41、 control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TA= +125C, minimum. b. Interim and fi

42、nal electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. 4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-ST

43、D-883 including groups A, B, C, and D inspections. The following additional criteria shall apply. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted. 4.3.2 Groups C and D inspections. a

44、. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available t

45、o the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA= +125C, minimum. (3) Test duration: 1,000 hours, except as permitted by

46、method 1005 of MIL-STD-883. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-90521 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 10 DSCC FORM 2234 APR 97 TABLE II. Electrical test requ

47、irements. MIL-STD-883 test requirements Subgroups (in accordance with MIL-STD-883, method 5005, table I) Interim electrical parameters (method 5004) 1 Final electrical test parameters (method 5004) 1*,2,3,4,5,6 Group A test requirements (method 5005) 1,2,3,4,5,6 Groups C and D end-point electrical p

48、arameters (method 5005) 1 * PDA applies to subgroup 1. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification