ECA 520EAAA-1989 Detail Specification for Surface Mountable Dual In-Line Switches of Certified Quality《已质量认证的表面可安装双列直插式开关的详细规范》.pdf

上传人:priceawful190 文档编号:704079 上传时间:2019-01-03 格式:PDF 页数:10 大小:374.76KB
下载 相关 举报
ECA 520EAAA-1989 Detail Specification for Surface Mountable Dual In-Line Switches of Certified Quality《已质量认证的表面可安装双列直插式开关的详细规范》.pdf_第1页
第1页 / 共10页
ECA 520EAAA-1989 Detail Specification for Surface Mountable Dual In-Line Switches of Certified Quality《已质量认证的表面可安装双列直插式开关的详细规范》.pdf_第2页
第2页 / 共10页
ECA 520EAAA-1989 Detail Specification for Surface Mountable Dual In-Line Switches of Certified Quality《已质量认证的表面可安装双列直插式开关的详细规范》.pdf_第3页
第3页 / 共10页
ECA 520EAAA-1989 Detail Specification for Surface Mountable Dual In-Line Switches of Certified Quality《已质量认证的表面可安装双列直插式开关的详细规范》.pdf_第4页
第4页 / 共10页
ECA 520EAAA-1989 Detail Specification for Surface Mountable Dual In-Line Switches of Certified Quality《已质量认证的表面可安装双列直插式开关的详细规范》.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、EIA 520EAAA 89 m 3234b00 0073553 T W ,- - ANSU ElA-52OEAAA-198f) APPROVED: Msiy 26,1989 EIA SPEC1 FICATION Detail Specification for Surf ace Mountable Dual In-line Switches of Certified Quality EIA-520EAAA JJNE lo89 ELECTRONIC IN DUSTRI ES ASSOCIATION ENGINEERING DEPARTMENT Amroved For Use In The NE

2、CQ Svstem I EIA 520EAAA 89 3234600 0073554 L W NOTICE EIA Engineering Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purcha

3、ser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or non-member of EIA from manufacturing or selling products not conforming to such Standards and Publications, nor s

4、hall the existence of suck Standards and Publications preclude their voluntary use by those other than EIA members, whether the standard is to be used either domestically or internationally. Recommended Standards and Publications are adopted by EIA without regard to whether or not their adoption may

5、 involve patents on articles, materials, or processes. By such action, EIA does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Recommended Standard or Publication. This EIA Specification is considered to have international standardiza

6、tion implication, but the International Electrotechnical Commission activity has not progressed to the point where a valid comparison between the EIA standard and the IEC document can be made. This Specification does not purport to address all safety problems associated with its use or all applicabl

7、e regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. (APPROVED FOR USE IN THE NECQ SYSTEM AS NQ-EIA-520EAAA.) Copyright 1989 Published by ELEC

8、TRONIC INDUSTRIES ASSOCIATION Engineering Department 1722 Eye Street, N.W. Washington, D.C. 20006 PRICE: $10.00 All rights reserved Printed in U.S.A. e EIA 520EAAA 89 m 3234b00 0073555 3 m EIA-520EAAA ELECTRONIC INDUSTRIES ASSOCIATION 2001 EYE STREET, N.W. WASHINGTON, D.C. 2- SENER IC SPECIFIC AT I

9、ON NUMBER EIA-5200000 ELECTRONIC COMPONENTS OF ACSESSED QUALITY IN ACCORDANCE WITH . OUTLINE DRAWING CIRCUIT DIAGRAM 3F SWITCH IN POSITION SHOWN. AS VIEWED FROM TOP ,286 (7.26) MAX. h- + .020*.002 (.51*.05) TYP. .300*. O I O 17.6t. 25) O TO 4 .O20 I.Si)-NOM. .O40 1 .o2 .o27 I .69) ,045 ( I . I 41 TY

10、P. (-1 .240 6.iO) TYP. OF .O35 R 4 fi .O90 (2.29) MAX. k- . iOOt.0p,2.54t. 13 FICUBE 1 NQt8a: 1. Original dimanriona ara inche 2. Th8 configur8tion ir option81 within the Ifaita of tha rpacifiad dimenriona. ETAIL SPECIFICATION NUMBER EIA-520- BLANK DETAIL ;PECIFICATION NUMBER EIA-520EA00 )RODUCT DES

11、CRIPTION DUAL-IN-LINE PACKAGE (DIP) SWITCH, SLIDE ACTUATED , MACHINE INSERTABLE, SURFACE MOUNTABLE MULTIPLE SPST STATIONS ELECTRICAL CIRCUIT SEE CIRCUIT DIAGRAM TYPICAL CONSTRUCTIOF HIGH TEMPERATURE PLASTIC APPLICATION/ ASSESSMENT LEVEL INFORMATION ON THE AVAILABILITY OF THE COMPONENTS QUALIFIED TO

12、THIS SPECIFICATION IS GIVEN IN THE QUALIFIED PRODUCTS LIST EIA 520EAAA 89 = 3234600 0073556 5 EIA-520EkU Page 1 DETAIL SPECIFICATION FOR SURFACE MOUNTABLE DUAL IN-LINE SWITCHES OF CERTIFIED QUALITY Introduction (From EA Standards Proposal No. 2191, formulated under the cognizance of the EIA P-13.4 S

13、ubcommittee on In-Line and Miscellaneous Switches.) The complete requirements forthe switches describedherein shall consist ofthis Detail Specification, the latest issue of EIA-520E000, “Sectional Specification for In-Line Switches of Certified Quality,g1 and the latest issue of EIA-5200000, “Generi

14、c Specification for Special-use Electromechanical switches of Certified Quality. II 1.0 SECTION ONE - SCOPE AND OBJECT 1.1 Scope The Dual In-line Surface Mountable Switches of certified quality covered by this Detail Specification: 1.1.1-. Have maximum enclosure dimensions of 32.5 mm (1.280 inch) lo

15、ng, 7.26 (0.286) wide and 4.57 (0.180) high. 1.1.2 Have a maximum rated voltage of 50 Vdc. 1.1.3 Have a maximum rated current of 100 mA. 1.1.4 Have slide actuators that are flush with, or recessed below, the top surface of the switch. 1.1.5 Are sealed against the entrance of soldering flux and clean

16、ing solutions during the process of assembly to circuit boards. 1.2 Object The object of this Detail Specification is to provide all information required for the identification, quality assessment, and certification of these switches. The information, contained herein or by reference, is complete an

17、d sufficient for inspection purposes. 2.0 SECTION TWO - GENERAL 2.1 The related documents, units, symbols, terminology and markings are prescribed in Section Two of Sectional Specification EIA 520E000, and General Speci- fication EIA 5200000, and the following additional requirements: 2.5.1 Switches

18、 shall be marked so as to identify .the state of the contacts with respect to the actuation position (i.e. “ON“ on appropriate side, a round dot on the closed contact side, etc.). EIA 520EAAA 89 W 3234600 0073557 7 EIA-52OEAAA Page 2 2.5.2 Part Number: Switches shall be identified as follows: EIA XX

19、XXXXX - XXX - - Type number from Table IV This Detail Specification number TABLE IV 1 Type No. .1 2 !3 /4 5 ;6 17 8 19 : 10 11 ! 12 i L I j Gull Wing i Form I J-Bend j Terminal Form O01 : 002 003 I 004 * 005 ! 006 ! 021 i 022 i 023 1 024 j 025 I 026 007 027 3.0 SECTION THREE - QUALITY ASSESSMENT PRO

20、CEDURES -* 3.1 4.0 4.1 O08 028 O09 029 - O10 O 30 - o11 I 012 031 032 I The quality assessment procedures are prescribed in Section Three or Sectional Specification EIA 520E000, and are supplemented by the following information: 3.1.1 Qualification Inspection Tests: The qualification tests are presc

21、ribed in Table I herein for the qualification of the entire subfamily of switches covered by this Detail Specification. Either gull wing, J-bend or I-type terminations can be used for qualification, but switches must have 8 poles. 3.4.5 Lot-By-Lot Inspection Tests: The lot-by-lot inspection tests ar

22、e prescribed in Table II herein. 3.4.6 Periodic Inspection Tests: The periodic inspection tests are prescribed in Table III herein. SECTION FOUR - TEST METHODS AND REQUIREMENTS General The test methods and requirements are prescribed in Section Four of Generic Specification EIA 5200000, Section Four

23、 of Sectional Specification EIA 520E000, and are supplemented by the following information: EIA 520EAAA 89 m 3234600 0073558 9 m EIA-52OEAAA Page 3 4.1.6 4.5.1 4.5.2. 4.6.1 4.8.1 4.9.1 4.11.1 4.19 4.25 Switches with tape top seals shall be supplied with contacts in the closed position and seals in p

24、lace for Group A, the solderability test of Group B, and the machine soldering test of Group C of Qualification Test Table I. These seals may be removed for all other qualification tests. Insulation resistance and voltage proof measurement in Group A only will be made between adjacent poles (the clo

25、sed circuit prevents taking these readings across open contacts). Switch Resistance Contact resistance is to be measured between the two terminals associated with each switch pole, and shall not exceed 20 milliohms initially and in Qualification Groups A and C, and 100 milliohms in Qualification Gro

26、ups B, D, E and Periodic Test Group B. Insulation Resistance Insulation resistance shall be measured at 100 2 5 Vdc, and at stan- dard atmospheric conditions. Insulation resistance shall not be less than 1000 megohms. Voltage Proof Voltage proof measurements shall be made with an applied voltage of

27、500 Vac (rms). Maximum allowable leakage current is 500 microamperes. The switch shall withstand the test voltage without sustained arcing, breakdown, or damage to insulation. Vibration Vibration testing shall be in accordance with EIA 186-8 Type III. Strength of Terminations Strength of termination

28、s shall be tested in accordance with EIA-186-6 with a 1.1 pound load on a minimum of three randomly selected terminals on each specimen. Electrical Endurance The electrical endurance test shall be run with one-half of the specimens tested in accordance with Test 8-4 (logic load) and one-half of the

29、specimens tested in accordance with Test 8-5 (low level load). The number of cycles shall be 2000, and no sticks or misses are allowed. Capacitance The maximum allowable capacitance shall be 5 picofarads. Machine Soldering (Vapor Phase) The machine soldering test shall be run in accordance with EIA

30、448-19 of this specification, and with Method A (immersion) cleaning using all four solutions. After the test, there shall be good solder connections, no externally visible indication of leakage, contact resistance shall be in accordance with 4.5.1, and insulation resistance shall be in accordance w

31、ith 4.5.2, and all marking shall be readable. EIA 520EAAA 89 3234b00 0073559 O E IA- 5 2 O EAAA Page 4 Test Method & Group TABLE I : QUALIFICATION APPROVAL INSPECTION TESTS Group A Visual Examination D hens ions Mass Switch Resistance Insulation Resistance Voltage Proof Group B Solderability Strengt

32、h of Terminations Electrical Endurance Switch Resistance Voltage Proof Group C Machine Soldering Visual Examination Switch Resistance Insulation Resistance Group D Thermal Shock Vibration Visual Examination Shock Visual Examination Switch Resistance Voltage Proof Group D Capacitance Moisture Resista

33、nce Switch Resistance Voltage Proof Test No. 1-1 1-2 1-4 2- 1 2-5 3- 1 11-1 See 4.9 See 4.11.1 2- 1 3- 1 See 4.24 1-1 2- 1 2-5 10-2 5- 3 1-1 5-2 1- 1 2- 1 3- 1 17-1 10- 1 2-1 3- 1 M/WS M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M D /ND - ND ND ND ND ND ND D D D ND ND D ND ND ND D D

34、ND D ND ND ND ND D ND ND - t.d g.d t.s. O Al 1 O (1) O (1) O All O Al 1 O All O 10 24 10 10 1 1 1 1 1 O 1 EIA 520EAAA 89 3234600 O073560 7 EIA-520EAM Page 5 TABLE II: LOT-BY-LOT INSPECTION TESTS Assessment Level C IL - Test Method & Group Test No. .D/ND Group A (Lot-By Lot) Visual Examination Ma j o

35、r Minor Switch Resistance Insulation Resistance Voltage Proof a I l Test Method & Group Group B (every 12 months) Solderability Strength of Terminations Electrical Endurance Switch Resistance Voltage Proof O Group C (every 36 months) Requalification 1- 1 ND 2- 1 ND 2-5 ND 3- 1 ND 11 Table III: PERIO

36、DIC INSPECTION TESTS t.s. - Test No. D/ND 20 11-1 D See 4.9 D See 4.11.1 D 2- 1 ND 3- 1 ND Table I D 1% t .d. 6.d. - 1 EIA-52QEAAA Page 6 KEY : M= mandatory test D= destructive test ND = nondestructive test t.s. = minimum quantity of test specimens t.d. = maximum permissible number defective units p

37、er test g.d. = maximum permissible number of defective units per group NOTES : (1) = A minimum of 2 pieces of each configuration covered by the Detail Specification. i. EIA 520EAAA 47 W 3234600 0073562 O I Standard or Generic Specification Indicator A EIA STANDARD AND SPECIFICATION NUMBERING STANDAR

38、D A document that establishes engineering and technical requirements for processes, procedures, practices and methods that have been decreed by authority or adopted by consensus. Standards may also be established for selection, application and design criteria for material. Standards and other docume

39、nts not in the specification format use only the EIA basic numbering system as follows: EIA-123 Original Standard EIA-123-1 Addendum to the Original Standard EIA-123-A First Revision of original Standard incorporating all Addenda SPECIFICATION A document prepared specifically to facilitate procureme

40、nt which clearly and accurately describes the essential technical requirements for purchased material. Procedures necessary to determine that the requirements for the purchased material covered by the specification have been met shall also be referenced or included. EIA Specifications use the follow

41、ing system: EIA123A -=?-TT Standard Prefix for all Numbers A - A - Detail Specification Designator EIA 1230000 is a Generic Specification EIA 123A000 is a Sectional Specification EIA 123AA00 is a Blank Detail Specification EIA 123AAAA is a Detail Specification EIA 12300AA is a Detail Specification for which no Sectional or Blank Detail Specification was issued NOTES 1. Some older specifications may not have been converted to this numbering system. 2. See EP-11, “Guide for the Preparation of Specifications Using IECQ-System Format,“ for more detail.