1、BS EN 12707:2009ICS 55.140NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDPlastics drums Non-removable head (tighthead) drums with anominal capacity of 210l and 225 lThis British Standardwas published under theauthority of the StandardsPolicy and StrategyCommitt
2、ee on 31 August2009 BSI 2009ISBN 978 0 580 60974 9Amendments/corrigenda issued since publicationDate CommentsBS EN 12707:2009National forewordThis British Standard is the UK implementation of EN 12707:2009. Itsupersedes BS EN 12707:2000 which is withdrawn.The UK participation in its preparation was
3、entrusted to TechnicalCommittee PKW/0, Packaging.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with
4、a British Standard cannot confer immunityfrom legal obligations.BS EN 12707:2009EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 12707July 2009ICS 55.140 Supersedes EN 12707:1999 English VersionPlastics drums - Non-removable head (tight head) drums with anominal capacity of 210 l and 225 lFts en ma
5、tire plastique - Fts ouverture partielle dunecapacit nominale de 210 l et 225 lKunststofffsser - Spundfsser mit einem Nennvolumenvon 210 l und 225 lThis European Standard was approved by CEN on 27 June 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the
6、 conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in t
7、hree official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of A
8、ustria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMM
9、ITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 12707:2009: EBS EN 12707:2009EN 12707:2009
10、 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms and definitions .44 Requirements .54.1 Dimensions .54.2 Drum mass .54.3 Material identification symbol 54.4 Closures 54.5 Materials .54.6 Handling 54.7 Stacking 54.8 Draining 54.9 Finish 65 Designation 6Annex A (normative) Capac
11、ity measurement method for non-removable head (tight head) plastics drums 8A.1 Principle 8A.2 Apparatus .8A.3 Procedure for determination of total capacity 8A.4 Procedure for determination of brimful capacity .9A.5 Expression of results 9Annex B (normative) Draining test method for non-removable hea
12、d (tight head) plastics drums . 10B.1 Principle . 10B.2 Apparatus 10B.3 Determination of drainability using the top section of the drum (procedure A) 10B.4 Determination of drainability using a complete drum (procedure B) 10B.5 Expression of results . 11Bibliography . 12BS EN 12707:2009EN 12707:2009
13、 (E) 3 Foreword This document (EN 12707:2009) has been prepared by Technical Committee CEN/TC 261 “Packaging”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the late
14、st by January 2010, and conflicting national standards shall be withdrawn at the latest by January 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all s
15、uch patent rights. This document supersedes EN 12707:1999. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,
16、France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 12707:2009EN 12707:2009 (E) 4 1 Scope This European Standard specifies the cha
17、racteristics and dimensions of non-removable head (tight head) plastics drums with a nominal capacity of 210 l and 225 l. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undate
18、d references, the latest edition of the referenced document (including any amendments) applies. EN ISO 20848-3, Packaging - Plastics drums - Part 3: Plug/bung closure systems for plastics drums with a nominal capacity of 113,6 l to 220 l (ISO 20848-3:2006) 3 Terms and definitions For the purposes of
19、 this document, the following terms and definitions apply. 3.1 non-removable head (tight head) drum (TH) flat-ended or convex-ended circular cross-section packaging with openings for filling and emptying in the head not exceeding 70 mm in diameter 3.2 nominal capacity (NC) capacity in litres which,
20、by convention, is used to represent a class of drums of similar brimful capacities 3.3 brimful capacity (BC) volume of water in litres held by the drum when filled through the filling orifice to the point of overflowing NOTE Annex A specifies the method for measuring brimful capacity. 3.4 total capa
21、city (TC) volume of water in litres held by the drum when filled completely, i.e. following the removal of any air trapped in the drum NOTE Annex A specifies the method for measuring total capacity. 3.5 overall height (ho) height of the finished drum from the base to the highest point NOTE See Figur
22、e 1. 3.6 overall diameter (do) maximum diameter of the drum, where relevant NOTE See Figure 1. 3.7 bung housing position (pb) distance from the centre of the bung housing to the outside of the drum body 50 mm vertically below the top edge of the top handling ring BS EN 12707:2009EN 12707:2009 (E) 5
23、NOTE See Figure 1. 3.8 drum mass mass of the empty drum including all closures 4 Requirements 4.1 Dimensions The dimensions and tolerances of the drum shall be as listed in Table 1 and as shown in Figure 1. The measurements shall be conducted at ambient conditions but shall not be made within 48 h o
24、f manufacture. NOTE Apart from the dimensions specified, there are no restrictions on drum shape. 4.2 Drum mass The mass tolerance of the drum shall be within 4 %. NOTE The defined mass should be agreed between the purchaser and the supplier. 4.3 Material identification symbol The drum shall be perm
25、anently marked with the relevant material identification symbol, i.e. the symbol identifying the material from which the drum is made. 4.4 Closures There shall be two closures, one of which shall be either a BCS 70 x 6 or a BCS 56 x 4 nominal plug size in accordance with EN ISO 20848-3. When fitted
26、the closures shall not protrude above the overall height of the drum. NOTE For the purpose of transport and storage, the filled drum should be closed, using the appropriate tooling, to the manufacturers recommended closure torque for each type of gasket. 4.5 Materials The drum shall be manufactured
27、either from high density polyethylene or another suitable plastics materials appropriate to the physical and chemical requirements of its intended use. 4.6 Handling Provision shall be made to enable the drum to be mechanically handled using one or two permanently fixed handling rings. The constructi
28、on of the handling rings shall be adequate for normal static and dynamic handling of filled drums. 4.7 Stacking The drum shall be capable of being stacked with or without pallets, according to the manufacturers recommendations. 4.8 Draining 4.8.1 The drum shall be designed so as to minimize the resi
29、dual volume of liquid left in the drum after drainage. The residue shall be not more than 100 ml when tested according to B.3 (procedure A). BS EN 12707:2009EN 12707:2009 (E) 6 4.8.2 The residue obtained when the drum is tested according to B.4 (procedure B) is more dependent on the area and conditi
30、on of the internal surface of the drum than procedure A and therefore can be in excess of that for procedure A. NOTE The maximum permitted figure should be agreed between the purchaser and the supplier. 4.9 Finish The external surface finish shall be suitable for the attachment of labels. NOTE 1 The
31、 nature of the internal and external finish should be agreed between the purchaser and the supplier. NOTE 2 The preferred colour option for the drum body is blue. The use of any other colour should be agreed between the purchaser and the supplier. 5 Designation A non-removable head (tight head) drum
32、 (TH) manufactured in accordance with this Standard shall be designated in the following manner: Plastics drum TH EN 12707 NC Nominal capacity EXAMPLE 1 A non-removable head (tight head) drum (TH) manufactured in accordance with this standard with a nominal capacity of 210 l or 225 l would be design
33、ated: Plastics drum TH EN 12707 NC 210 l to 225 l. EXAMPLE 2 A non-removable head (tight head) drum with a nominal capacity of 225 l would be designated: Plastics drum TH EN 12707 NC - 225 l NOTE Where the drums are intended to be used for the transport of dangerous goods, attention is drawn to the
34、regulatory requirements which govern the transport of those goods in the countries concerned. In Europe, depending upon the mode of transport, this means meeting the requirements of: European Agreement Concerning the International Carriage of Dangerous Goods by Road (ADR); Regulations concerning the
35、 International Carriage of Dangerous Goods by Rail (RID); Technical Instructions for the Safe Transport of Dangerous Goods by Air, Document 9284-AN/905 published by the Council of the International Civil Aviation Organization (ICAO); The International Maritime Dangerous Goods Code (IMDG-CODE) publis
36、hed by the International Maritime Organization (IMO). Table 1 Dimensions of non-removable (tight head) drums with a nominal capacity of 210 l and 225 l Nominal capacity (NC) L Brimful capacity (BC) l Overall diameter (do) mm Bung housing position (pb) mm Overall height (ho) mm 210 213 3 580 5 928 5
37、225 228 3 582 3 72 2 965 5 NOTE 1 The bung housing position defined in this table only applies to that housing used for filling. NOTE 2 Dimensions do, pband hoare applicable to empty drums. BS EN 12707:2009EN 12707:2009 (E) 7 Dimensions in mm Key 1 bung housing position 2 overall diameter 3 overall
38、height Figure 1 Non-removable head (tight head) drum with a nominal capacity of 210 l and 225 l BS EN 12707:2009EN 12707:2009 (E) 8 Annex A (normative) Capacity measurement method for non-removable head (tight head) plastics drums A.1 Principle The capacity is determined by a gravimetric method i.e.
39、 by the measurement of the mass of water in the filled drum and its conversion to a capacity. A correction factor (see EN ISO 90-2:1999, 4.1.1.) can be applied according to Table A.1, but only if the weighing scale used is of a higher precision than the correction. NOTE For plastics drums the water
40、temperature should not exceed 18C. Table A.1 Correction factors Water temperature C Correction factor (F) 12 1,000 5 14 1,000 8 16 1,001 1 18 1,001 4 A.2 Apparatus Weighing scale, with an accuracy of at least 0,1% of the weight being measured. A.3 Procedure for determination of total capacity A.3.1
41、Drill a hole of diameter 5 mm to 10 mm for venting at the highest point of the closed drum. NOTE The position of the hole depends on the profile of the top. A.3.2 Weigh the empty drum and record its mass, m1,in grams. A.3.3 Measure the temperature of the tap water to be used to fill the drum. A.3.4
42、Fill the drum 100 % with water through the normal filling closure with all other closures fitted and make sure that the air is vented through the drilled hole. NOTE For certain drums, the drum needs to be inclined or tilted, so that the filling hole is at the highest position. A.3.5 Fit and secure t
43、he drum closure and remove any surplus water from the outside. A.3.6 Weigh the filled drum and record its mass, m2, in grams. BS EN 12707:2009EN 12707:2009 (E) 9 A.4 Procedure for determination of brimful capacity Follow the same procedure as for the determination of total capacity (see A.3) with th
44、e exception that no hole is drilled to vent entrapped air. Fill the drum, with the drum in the normal position for filling, until water overflows at the closure. A.5 Expression of results The difference between the mass of the filled drum, m2, and the mass of the empty drum, m1, (m2 m1), if necessar
45、y multiplied by the correction factor (F), represents the capacity of the drum as determined by the procedure used. BS EN 12707:2009EN 12707:2009 (E) 10 Annex B (normative) Draining test method for non-removable head (tight head) plastics drums B.1 Principle The absolute drainability and the relativ
46、e drainability are obtained by determining the mass of water left as a residue in the drum after drainage under gravity. B.2 Apparatus Weighing scale, with an accuracy of at least 2 g. B.3 Determination of drainability using the top section of the drum (procedure A) B.3.1 Cut the top off the drum. B
47、.3.2 Retain the top section and fit the appropriate closure(s). B.3.3 Weigh the top section with closure(s) fitted, and record its mass, m1,in grams. B.3.4 Position the top section, top down, on a test rig so that it is held at the angle specified by the manufacturer (preferably 0 to 20) with the de
48、signated closure opening at its lowest position. B.3.5 Fill the top section with approximately 10 l of tap water. B.3.6 Wait until the water surface has settled and then open the closure. B.3.7 Allow the water to drain for 5 min without moving or shaking the top section and refit the closure. B.3.8
49、Re-weigh the top section, still in the top down position, and record its mass, m2, in grams. B.4 Determination of drainability using a complete drum (procedure B) B.4.1 Weigh the empty drum including its closure(s), and record its mass, m1, in grams. B.4.2 Fill the drum with a limited quantity of tap water, approximately 10 l. Close the drum. B.4.3 Rotate the drum to ensure a wetting of all inner surfaces. B.4.4 Open th