EN 13830-2015 en Curtain walling - Product standard《幕墙 产品标准》.pdf

上传人:towelfact221 文档编号:708356 上传时间:2019-01-03 格式:PDF 页数:94 大小:2.53MB
下载 相关 举报
EN 13830-2015 en Curtain walling - Product standard《幕墙 产品标准》.pdf_第1页
第1页 / 共94页
EN 13830-2015 en Curtain walling - Product standard《幕墙 产品标准》.pdf_第2页
第2页 / 共94页
EN 13830-2015 en Curtain walling - Product standard《幕墙 产品标准》.pdf_第3页
第3页 / 共94页
EN 13830-2015 en Curtain walling - Product standard《幕墙 产品标准》.pdf_第4页
第4页 / 共94页
EN 13830-2015 en Curtain walling - Product standard《幕墙 产品标准》.pdf_第5页
第5页 / 共94页
点击查看更多>>
资源描述

1、BSI Standards PublicationBS EN 13830:2015Curtain walling ProductstandardBS EN 13830:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 13830:2015. Itsupersedes BS EN 13830:2003 which is withdrawn.The UK participation in its preparation was entrusted to Technic

2、alCommittee B/538/6, Curtain walling.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Instit

3、ution 2015. Published by BSI StandardsLimited 2015ISBN 978 0 580 82650 4ICS 91.060.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 April 2015.Amendments issue

4、d since publicationDate Text affectedBS EN 13830:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13830 April 2015 ICS 91.060.10 Supersedes EN 13830:2003 English Version Curtain walling - Product standard Faades rideaux - Norme de produit Vorhangfassaden - Produktnorm This European Standard

5、was approved by CEN on 7 February 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such

6、 national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own

7、language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Gr

8、eece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUN

9、G CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13830:2015 E BS EN 13830:2015EN 13830:2015 (E) 2 Contents Page Foreword 6 Introduction .7 1 Scope 8 2 Normative

10、 references 8 3 Terms, definitions and abbreviated terms . 12 3.1 Definitions . 12 3.2 Abbreviations used in this standard. 14 4 Product characteristics 14 4.1 Reaction to fire (of components, when relevant) 14 4.2 Fire resistance . 14 4.3 Fire propagation (to upper levels) . 14 4.4 Watertightness 1

11、5 4.5 Resistance to its own dead load . 15 4.6 Wind load resistance 15 4.7 Resistance to snow load (only for elements subjected to snow load) . 15 4.8 Impact resistance 16 4.8.1 General . 16 4.8.2 Internal . 16 4.8.3 External 16 4.9 Resistance to live horizontal loads at sill level . 16 4.10 Seismic

12、 resistance . 16 4.10.1 General . 16 4.10.2 Safety in use 16 4.10.3 Serviceability (where specially required) . 17 4.11 Thermal shock resistance 17 4.12 Direct airborne sound insulation 17 4.13 Flanking sound transmission 17 4.14 Thermal transmittance . 17 4.15 Air permeability . 17 4.16 Water vapou

13、r permeability . 17 4.17 Radiation properties . 17 4.18 Equipotential bonding (protection against electric shock) (where specifically required) 17 4.19 Durability . 18 4.19.1 General . 18 4.19.2 Durability of watertightness 18 4.19.3 Durability of thermal transmittance 18 4.19.4 Durability of air pe

14、rmeability . 19 5 Testing, assessment and sampling methods 19 5.1 Sampling 19 5.1.1 General . 19 5.1.2 Sequence of testing 19 5.2 Reaction to fire (of components, when relevant) 20 5.3 Fire resistance . 20 5.4 Fire propagation (to upper levels) . 20 5.5 Watertightness 20 5.6 Resistance to its own de

15、ad load . 21 5.7 Wind load resistance 21 5.8 Resistance to snow load (only for elements subject to snow load) 21 BS EN 13830:2015EN 13830:2015 (E) 3 5.9 Impact resistance 21 5.10 Resistance to live horizontal loads at sill level 22 5.11 Seismic resistance 22 5.11.1 Safety in use 22 5.11.2 Serviceabi

16、lity (where specially required) 22 5.12 Direct airborne sound insulation . 22 5.13 Flanking sound transmission. 23 5.14 Thermal transmittance 23 5.15 Air permeability . 23 5.16 Radiation properties 23 5.17 Equipotential bonding (protection against electric shock) (where specifically required) . 23 5

17、.18 Durability 23 5.18.1 General . 23 5.18.2 Durability of watertightness . 24 5.18.3 Durability of thermal transmittance . 24 5.18.4 Durability of air permeability 25 6 Assessment and verification of constancy of performance (AVCP) . 25 6.1 General . 25 6.2 Type testing . 25 6.2.1 General . 25 6.2.

18、2 Test samples, testing and compliance criteria 26 6.2.3 Test reports 27 6.2.4 Cascading determination of the product type results . 27 6.3 Factory production control (FPC) 28 6.3.1 General . 28 6.3.2 Requirements . 29 6.3.3 Product specific requirements . 32 6.3.4 Initial inspection of factory and

19、of FPC . 33 6.3.5 Continuous surveillance of FPC (only for curtain walling kits covered by AVCP system 1) 33 6.3.6 Procedure for modifications. 33 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity . 34 7 Marking, labelling 34 Annex A (inform

20、ative) Maintenance 36 Annex B (informative) Equipotential bonding conditions . 37 B.1 General requirements . 37 B.2 Connectors . 37 Annex C (informative) Resistance to actions: guidance on the use of Eurocodes 38 C.1 Introduction of the annex . 38 C.2 Scope of the annex 38 C.3 Symbols and abbreviati

21、ons in the annex 38 C.4 Definition and principle . 39 C.4.1 General . 39 C.4.2 Classes of consequence. 40 C.4.3 Curtain walling kit operating as safety barrier . 40 C.4.4 Loaded area “A“ 40 C.4.5 System redundancy 42 C.5 Requirements . 42 BS EN 13830:2015EN 13830:2015 (E) 4 C.6 Actions . 42 C.6.1 De

22、ad load action . 42 C.6.2 Wind action 42 C.6.3 Actions for curtain walling serving as parapets 43 C.7 Assumptions related the combinations of actions . 44 C.7.1 General . 44 C.7.2 Combinations of actions: generalities 44 Annex D (normative) Seismic resistance . 49 D.1 General principles. 49 D.1.1 Re

23、quired performance limits . 49 D.1.2 Factors affecting seismic performance 49 D.2 Assessment of seismic serviceability limit 49 D.3 Assessment of seismic safety limit 50 D.4 Seismic movement regime 50 D.4.1 General . 50 D.4.2 Principles . 51 D.4.3 Test apparatus 51 D.4.4 Test procedure 51 Annex E (n

24、ormative) Selection, preparation, mounting and fixing of test specimen for reaction to fire tests of curtain walling and field of direct application . 56 E.1 General . 56 E.2 EN ISO 11925-2:2010 (Single flame test) 57 E.2.1 Profile . 57 E.2.2 Infill . 59 E.2.3 Sealing between infill and profile 59 E

25、.2.4 Organic coating/top layers 61 E.3 Mounting and fixing for EN 13238 (SBI-test) 61 E.4 EN ISO 1182 (Non-combustibility test) . 62 E.5 EN ISO 1716 (Determination of the heat of combustion) 62 E.6 Field of direct application 63 Annex F (normative) Characteristics and range of direct application 64

26、F.1 General . 64 F.2 Selection of a representative test specimen 69 Annex G (informative) Characteristics and performances of curtain walling kit . 71 Annex H (informative) Interchangeability between characteristics and components 73 Annex I (informative) Basic approach to durability 75 Annex ZA (in

27、formative) Clauses of this standard addressing the provisions of the EU Construction Product Regulation . 77 ZA.1 Scope and relevant characteristics 77 BS EN 13830:2015EN 13830:2015 (E) 5 ZA.2 Procedure for AVCP of curtain walling kit 79 ZA.2.1 System(s) of AVCP 79 ZA.2.2 Declaration of performance

28、(DoP) . 81 ZA.2.2.1 General 81 ZA.2.2.2 Content 81 ZA.2.2.3 Example of DoP 82 ZA.3 CE Marking and labelling 85 Bibliography 89 BS EN 13830:2015EN 13830:2015 (E) 6 Foreword This document (EN 13830:2015) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hadware and

29、 curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2015, and conflicting national standards shall be withdrawn at the latest by J

30、anuary 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13830:2003. This document has been prepared u

31、nder a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive, see informative Annexe ZA, which is an integral part of this document. The new revision extends the scope to slo

32、ping parts included in the curtain walling kit and clarifies the exclusion of the following products: “Patent glazing” (glazed sloping roofs) kits; Roof glazing constructions; Faades made of precast concrete panels as part of the wall (see EN 14992). Here below the list the most important changes co

33、mpared with the previous version EN 13830:2003: new characteristics were added; new annexes were introduced, particularly the one for the range of direct application of characteristics (extension rules); the durability was dealt in details in Annex I; updated Clause 6 and Annex ZA with the provision

34、s of the EU Construction Product Regulation No. 305/2011. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, F

35、inland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 13830:2015EN 13830:2015

36、 (E) 7 Introduction This European Standard specifies the technical characteristics of curtain walling kit and includes a systematic framework of requirements, test methods and compliance criteria to allow the product to fulfil with it. Curtain walling kit might not be completed in all respects withi

37、n a manufacturing area, and some kit components could be supplied separately on site. Curtain walling kit could be also preassembled in plant(s) as prefabricated units. BS EN 13830:2015EN 13830:2015 (E) 8 1 Scope This European Standard specifies requirements of curtain walling kit intended to be use

38、d as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances. The curtain walling kit covered by this standard should fulfil its own integrity and mech

39、anical stability but does not contribute to the load bearing or stability of the main building structure, and could be replaced independently of it. This standard applies to curtain walling kit ranging from a vertical position to 15 from the vertical. Any sloping parts should be contained within the

40、 curtain walling kit. This standard is applicable to the whole of the curtain walling kits, including the fixings. Curtain walling according to this standard is intended to be used as part of the building envelope. This European Standard does not include: “Patent glazing” (glazed sloping roofs) kits

41、; Roof glazing constructions; Faades made of precast concrete panels as part of the wall (see EN 14992). NOTE 1 Precast concrete panels may be used in curtain walling kits as infill panels. NOTE 2 Durability of structural sealed glazing infills is not covered by this standard. 2 Normative references

42、 The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 410

43、, Glass in building - Determination of luminous and solar characteristics of glazing EN 1096-2, Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings EN 1096-3, Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D

44、 coatings EN 1096-4, Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard EN 1279-1, Glass in Building - Insulating glass units - Part 1: Generalities, dimensional tolerances and rules for the system description EN 1279-2, Glass in building - Insulating glass units -

45、Part 2: Long term test method and requirements for moisture penetration EN 1279-3, Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances EN 1279-4, Glass in building - Insulating glass units - Part 4: Met

46、hods of test for the physical attributes of edge seals BS EN 13830:2015EN 13830:2015 (E) 9 EN 1279-5, Glass in building - Insulating glass units - Part 5: Evaluation of conformity EN 1364-3, Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete a

47、ssembly) EN 1364-4, Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration EN 1991-1-1, Eurocode 1: Actions on structures - Part 1-1: General actions - Densities, self-weight, imposed loads for buildings EN 1991-1-3, Eurocode 1 - Actions on structures - Par

48、t 1-3: General actions - Snow loads EN 1991-1-4, Eurocode 1: Actions on structures - Part 1-4: General actions - Wind actions EN 1998-1:2004, Eurocode 8: Design of structures for earthquake resistance - Part 1: General rules, seismic actions and rules for buildings EN 12152, Curtain walling - Air pe

49、rmeability - Performance requirements and classification EN 12153, Curtain walling - Air permeability - Test method EN 12154, Curtain walling - Watertightness - Performance requirements and classification EN 12155, Curtain walling - Watertightness - Laboratory test under static pressure EN 12179, Curtain walling - Resistance to wind load - Test method EN 12354-1, Building Acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms EN 12365-1, Building hardware - Gasket