EN 4165-013-2005 1250 Connectors electrical rectangular modular Operating temperature 175 degrees C continuous Part 013 Cable clamp 2 and 4 modules for connectors series 2 and seri.pdf

上传人:boatfragile160 文档编号:711653 上传时间:2019-01-03 格式:PDF 页数:10 大小:232.39KB
下载 相关 举报
EN 4165-013-2005 1250 Connectors electrical rectangular modular Operating temperature 175 degrees C continuous Part 013 Cable clamp 2 and 4 modules for connectors series 2 and seri.pdf_第1页
第1页 / 共10页
EN 4165-013-2005 1250 Connectors electrical rectangular modular Operating temperature 175 degrees C continuous Part 013 Cable clamp 2 and 4 modules for connectors series 2 and seri.pdf_第2页
第2页 / 共10页
EN 4165-013-2005 1250 Connectors electrical rectangular modular Operating temperature 175 degrees C continuous Part 013 Cable clamp 2 and 4 modules for connectors series 2 and seri.pdf_第3页
第3页 / 共10页
EN 4165-013-2005 1250 Connectors electrical rectangular modular Operating temperature 175 degrees C continuous Part 013 Cable clamp 2 and 4 modules for connectors series 2 and seri.pdf_第4页
第4页 / 共10页
EN 4165-013-2005 1250 Connectors electrical rectangular modular Operating temperature 175 degrees C continuous Part 013 Cable clamp 2 and 4 modules for connectors series 2 and seri.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、BRITISH STANDARD AEROSPACE SERIESBS EN 4165-013:2005Connectors, electrical, rectangular, modular Operating temperature 175 C continuous Part 013: Cable clamp 2 and 4 modules for connectors, series 2 and series 3 Product standardThe European Standard EN 4165-013:2005 has the status of a British Stand

2、ardICS 49.060g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 4165-013:2005This British Standard was published under the authority of the Stand

3、ards Policy and Strategy Committee on 28 February 2006 BSI 28 February 2006ISBN 0 580 47897 1National forewordThis British Standard is the official English language version of EN 4165-013:2005. The UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic elec

4、trical and fibre optic technology, to Subcommittee ACE/6/-/3, Aerospace connectors, which has the responsibility to: A list of organizations represented on this subcommittee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European pu

5、blications referred to in this document may be found in the BSI Catalogueunder the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the ne

6、cessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the in

7、terpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 7 and a back cover.The BSI copyrigh

8、t notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORMEN 4165-013 November 2005 ICS 49.060English Version Aerospace series - Connectors, electrical, rectangular, modula

9、r -Operating temperature 175 C continuous - Part 013: Cable clamp 2 and 4 modules for connectors, series 2 and series 3 - Product standard Srie arospatiale - Connecteurs lectriques rectangulaires modulaires - Temprature dutilisation 175 C continu - Partie 013 : Serre-cbles 2 et 4 modules pour connec

10、teurs, srie 2 et srie 3 - Norme de produit Luft- und Raumfahrt - Elektrischer Rechtecksteckverbinder in modularer Bauweise - Betriebstemperatur 175 C konstant - Teil 013: Gehuse fr Zugentlastung fr Steckverbinder mit 2 und 4 Modulen, Serie 2 und Serie 3 - Produktnorm This European Standard was appro

11、ved by CEN on 30 September 2005. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nation

12、al standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and noti

13、fied to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherl

14、ands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any fo

15、rm and by any means reserved worldwide for CEN national Members. Ref. No. EN 4165-013:2005: E2Contents PageForeword 31 Scope .42 Normative references .43 Terms and definitions.44 Required characteristics 45 Cable clamp.56 Designation .77 Marking 78 Technical specification.7EN 4165-013:20053Foreword

16、This European Standard (EN 4165-013:2005) has been prepared by the European Association of Aerospace Manufacturers - Standardization (AECMA-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associati

17、ons and the Official Services of the member countries of AECMA, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2006, and conflicting national standards shall

18、 be withdrawn at the latest by May 2006. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulat

19、ions, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norw

20、ay, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 4165-013:200541 Scope This standard defines cable clamp 2 and 4 modules for connectors, series 2 and series 3 used in the family of rectangular electrical connectors. 2 Normative references The following

21、referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2424, Aerospace series Marking of aerospace products.EN 4165

22、-001, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous Part 001: Technical specification.EN 4165-002, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous Part 002: Specification of performance and co

23、ntact arrangements.3 Terms and definitions For the purposes of this standard, the terms and definitions given in EN 4165-001 apply. 4 Required characteristics See Figure 1 for 2 modules and Figure 2 for 4 modules. EN 4165-013:200555 Cable clamp 5.1 For 2 modules classes W, F and A Dimensions are in

24、millimetres. Key1 see Figure 3. Figure 1 5.2 For 4 modules classes W, F and A Dimensions are in millimetres. Key1 see Figure 3. Figure 2 EN 4165-013:200565.3 Cable clamp class See Table 1. Table 1 Class Description WCable clamp with housing (shell) olive drab cadmium plated, aluminium alloy, conduct

25、ing finish, 500 hours resistance to salt mist, maximum operating temperature 175 C continuous FCable clamp with housing (shell) black nickel plated, aluminium alloy, 96 hours resistance to salt mist, maximum operating temperature 175 C continuous ACable clamp with housing (shell) black anodised plat

26、ed, aluminium alloy, no conducting finish, 48 hours resistance to salt mist, maximum operating temperature 175 C continuous 5.4 Intermateability for series 2 and series 3 See Figure 3. Dimensions are in millimetres. Key1 4 modules 70,9 max. 2 modules 40,4 max. Figure 3 EN 4165-013:200576 Designation

27、 EXAMPLE Description block ELECTRICAL CONNECTOR CABLE CLAMPIdentity block EN4165F13A4Number of the basic standard Class type (see Table 1) Type 13: Cable clamp (see EN 4165-002) A = series 2 or series 3 Shell type 4 = plug 4 modules 2 = plug 2 modules 7 Marking Unless there are other specific contra

28、ctual requirements, the marking shall be in accordance with EN 2424, category P. 8 Technical specification See EN 4165-001. EN 4165-013:2005BS EN 4165-013:2005BSI389 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the independent national body responsible for preparing British

29、Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of British Standards should make sure that they possess the latest amendments or editions.It is the con

30、stant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the identity of which can be found on the inside front cover. T

31、el: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should be address

32、ed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-.In response to orders for international standards, it is BSI policy to supply the BSI implementation of those that have been published a

33、s British Standards,unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI electronic information services are also available which give

34、 details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-.Subscribing members of BSI are kept up to date with standards developments and receive substantial discounts on the purchase price of standards. For details

35、of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-.Information regarding online access to British Standards via British Standards Online can be found at http:/www.bsi- information about BSI is available on the BSI

36、website at http:/www.bsi-.CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patents Act 1988 no extract may be reproduced, stored in a ret

37、rieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI.This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained.Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553. Email: copyrightbsi-.

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1